DIN EN 50019 : 2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
02-01-2004
01-12-2013
1 Scope
2 Normative references
3 Definitions
4 Constructional requirements for all electrical
apparatus
5 Supplementary constructional requirements for
specific electrical apparatus
6 Type verifications and type tests
7 Routine verifications and routine tests
8 Marking
Annex A (informative) - Cage motors - Thermal protection in
service
Annex B (normative) - Lampholders and lamp caps for luminaires
designed for mains supply
Annex C (informative) - Combinations of terminals and
conductors for general purpose
connection and junction boxes
Annex D (informative) - Additional electrical protection for
resistance heating devices
Annex E (normative) - Cage motors - Methods of test and of
calculation
Annex F (normative) - Type tests for specific forms of
resistance heating device and/or
resistance heating unit
Tables
Figures
Provides requirements for the construction, testing and marking of electrical apparatus with type of protection increased safety "e" meant for use in explosive gas atmospheres.
DocumentType |
Standard
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NBN EN 50019 : 2001 | Identical |
NEN EN 50019 : 2000 C1 2003 | Identical |
I.S. EN 50019:2001 | Identical |
SN EN 50019 : 2000 | Identical |
NF EN 50019 : 1996 | Identical |
EN 50019:2000/corrigendum Apr. 2003 | Identical |
BS EN 50019:2000 | Identical |
VDE 0170-6 : 2016 | Corresponds |
VDE 0101 : 2000 | POWER INSTALLATIONS EXCEEDING 1 KV |
DIN 57166 : 1981 | ELECTRICAL INSTALLATIONS AND EQUIPMENT FOR USE IN ATMOSPHERES POTENTIALLY ENDANGERED BY EXPLOSIVE MATERIAL |
DIN EN 50015 : 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - OIL IMMERSION 'O' |
VDE 0400-40-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
VDE 0400-6 : 2000 | GUIDE FOR THE SELECTION, INSTALLATION, USE AND MAINTENANCE OF APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES |
VDE 0170/0171-3 : 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - PRESSURIZED APPARATUS "P" |
DIN VDE 0170/0171-14 : 1992 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES; CAP LIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP |
VDE 0165-10 : 1999 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES) |
BWB TL 4440-0002 : 5ED 1998 | AIR DRIER, ROOM, ELECTRIC, EXPLOSION PROOF, FOR ROOMS UP TO 250 CBM |
DIN 40012-1:1984-05 | PROTECTION AGAINST EXPLOSION - MARKING OF ELECTRICAL EQUIPMENT - SIGNS AND PLATES |
VDE 0170/0171-14 : 1992 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - CAPLIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP |
DIN EN 61779-1 : 2001 AMD 11 2004 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
DIN EN 50073 : 2000 | GUIDE FOR THE SELECTION, INSTALLATION, USE AND MAINTENANCE OF APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES OR OXYGEN |
DIN 42673-2:1983-04 | TOTALLY ENCLOSED FAN-COOLED THREE-PHASE INDUCTION MOTORS WITH SQUIRREL-CAGE TYPE IM B 3, WITH ROLLING BEARINGS - RELATIONSHIP FRAME SIZES - OUTPUT RATINGS FOR TYPE OF PROTECTION INCREASED SAFETY "E" |
DIN V ENV 50269 : 1998 | ASSESSMENT AND REPRESENTATIVE TESTING OF HIGH-VOLTAGE MACHINES |
VDI/VDE 2189 Blatt 3:1994-10 | Three-level stepping controllers - Methods of evaluation the performance |
VDE 0170-12-2 : 2001-05 | GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST |
DIN EN 50014 : 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
DIN EN 50303 : 2001-05 | GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST |
VDE 0166 : 81 AMD 1 87 | ELECTRICAL INSTALLATIONS AND APPARATUS THEREOF FOR USE IN ATMOSPHERES POTENTIALLY ENDANGERED BY EXPLOSIVE MATERIAL |
DIN EN 50241-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
VDE 0118 SUPP 1 : 1998 | ERECTION OF ELECTRICAL INSTALLATIONS IN MINES - GUIDE FOR THE PREPARATION OF A TECHNICAL DOCUMENTATION IN THE SENSE OF THE MACHINE DIRECTIVE |
DIN 42677-2:1983-04 | TOTALLY ENCLOSED FAN-COOLED THREE-PHASE INDUCTION MOTORS WITH SQUIRREL-CAGE, TYPE IM B 5, IM B 10, IM B 14, WITH ROLLING BEARINGS - RELATIONSHIP FRAME SIZES - OUTPUT RATINGS FOR TYPE OF PROTECTION INCREASED SAFETY "E" |
DIN EN 50284 : 2000 | SPECIAL REQUIREMENTS FOR CONSTRUCTION, TEST AND MARKING OF ELECTRICAL APPARATUS OF EQUIPMENT GROUP II, CATEGORY 1 G |
DIN EN 50017 : 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - POWDER FILLING 'Q' |
VDE V 0170/0171-60 : 1998 | ASSESSMENT AND REPRESENTATION TESTING OF HIGH-VOLTAGE MACHINES |
DIN EN 50018 : 2001 AMD 1 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D" |
Access your standards online with a subscription