DIN EN 1822-1:2011-01
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING
Hardcopy , PDF
10-07-2019
English
01-01-2011
Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen, Symbole und Abkürzungen
3.1 Definitionen
3.2 Symbole und Abkürzungen
4 Klassifikation
4.1 Filtergruppen
4.2 Filterklassen
5 Anforderungen
5.1 Allgemeines
5.2 Werkstoffe
5.3 Nennvolumenstrom
5.4 Druckdifferenz
5.5 Filtrationsleistung
6 Prüfverfahren
6.1 Prüfstände
6.2 Prüfbedingungen
6.3 Prüfaerosol
6.4 Verfahrensübersicht
6.5 Prüfverfahren
7 Filterbeurteilung, Dokumentation
8 Kennzeichnung
This standard is included in DIN Handbook 85.
DevelopmentNote |
Supersedes DIN 24184 and DIN 24183-1. (05/2001) DRAFT 2017 issued in July 2017. (07/2017)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
Standards | Relationship |
SN EN 1822-1 : 2010 | Identical |
NS EN 1822-1 : 2009 | Identical |
I.S. EN 1822-1:2009 | Identical |
ONORM EN 1822-1 : 2011 | Identical |
EN 1822-1:2019 | Identical |
NEN EN 1822-1 : 2009 | Identical |
BS EN 1822-1:2009 | Identical |
UNE-EN 1822-1:2010 | Identical |
UNI EN 1822-1 : 2010 | Identical |
NF EN 1822-1 : 2010 | Identical |
EN 1822-1:2009 | Identical |
NBN EN 1822-1 : 2010 | Identical |
KTA 1503.1 : 2016(R2017) | MONITORING THE DISCHARGE OF RADIOACTIVE GASES AND AIRBORNE RADIOACTIVE PARTICULATES - PART 1: MONITORING THE DISCHARGE OF RADIOACTIVE MATTER WITH THE STACK EXHAUST AIR DURING SPECIFIED NORMAL OPERATION |
VDI 3677 Blatt 2:2004-02 | Filtering separators - Depth fiber filters |
VDI/GVSS 6202 Blatt 1:2013-10 | Contaminated buildings and technical installations - Demolition, refurbishing and maintenance |
VDI 4300 Blatt 11:2013-12 | Measurement of indoor air pollution - Measurement strategies for determination of airborne particles in indoor environment - PM-fraction |
VDI 3678 Blatt 2:2010-12 | Electrostatic precipitators - Process air and indoor air cleaning |
VDI 6032 Blatt 1:2015-05 | Ventilation and indoor-air quality in vehicles - Hygiene requirements for ventilation and air-conditioning systems |
VDI 3491 Blatt 15:1996-12 | Particulate matter measurement - Generation of test aerosols - Dilution systems with continuous volumetric flow |
VDI 6022 Blatt 5:2016-11 | Ventilation and indoor-air quality - Avoidance of allergenic exposure - Requirements regarding the testing and evaluation of technical products and components affecting the indoor air |
VDI 6300 Blatt 1:2016-05 | Genetic engineering operations in genetic engineering facilities - Guidance on safe operation of genetic engineering facilities |
VDI 2464 Blatt 3:2012-07 | Ambient air measurement - Indoor air measurement - Measurement of polybrominated diphenylether, hexabromocyclododecane and hexabromobenzene by GC/MS |
VDI 2083 Blatt 3:2005-07 | Cleanroom technology - Metrology and test methods |
DIN HDBK 85 : 11ED 2017 | RAUMLUFTTECHNISCHE ANLAGEN VOB/STLB-BAU - VOB TEIL C: ATV DIN 18299, ATV DIN 18379 |
DIN 18379:2016-09 | GERMAN CONSTRUCTION CONTRACT PROCEDURES (VOB) - PART C: GENERAL TECHNICAL SPECIFICATIONS IN CONSTRUCTION CONTRACTS (ATV) - INSTALLATION OF AIR CONDITIONING SYSTEMS |
DIN EN 16913:2015-10 (Draft) | AMBIENT AIR - STANDARD METHOD FOR MEASUREMENT OF NO[3][-], SO[4][2-], CL[-], NH[4][+], NA[+], K[+], MG[2+], CA[2+] IN PM2,5 AS DEPOSITED ON FILTERS |
EN 1822-5:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements |
EN 1822-2:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 2: Aerosol production, measuring equipment, particle counting statistics |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
ISO 14644-3:2005 | Cleanrooms and associated controlled environments Part 3: Test methods |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
EN 1822-3:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media |
EN 1822-4:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method) |
EN 14799:2007 | Air filters for general air cleaning - Terminology |
EN ISO 14644-3:2005 | Cleanrooms and associated controlled environments - Part 3: Test methods (ISO 14644-3:2005) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.