DIN EN 1456-1:2001-12
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PLASTICS PIPING SYSTEMS FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPING COMPONENTS AND THE SYSTEM
Hardcopy , PDF
04-01-2010
DIN EN ISO 1452-1:2010-04
DIN EN ISO 1452-5:2010-04
DIN EN ISO 1452-2:2010-04
DIN EN ISO 1452-3:2010-04
DIN EN ISO 1452-4:2010-04
English
01-01-2001
Foreword
1 Scope
2 Normative references
3 General
3.1 Definitions, symbols and abbreviations
3.2 Material
4 Pipes
4.1 Pipe material
4.2 General characteristics
4.3 Geometrical characteristics
4.4 Classification and selection
4.5 Mechanical characteristics
4.6 Physical characteristics
4.7 Sealing rings
4.8 Adhesives
4.9 Performance requirements
4.10 Marking
4.11 Allowable operating pressures
5 Fittings
5.1 Material
5.2 General characteristics
5.3 Geometrical characteristics of fittings
5.4 Mechanical characteristics
5.5 Physical characteristics
5.6 Sealing rings
5.7 Adhesives
5.8 Performance requirements
5.9 Marking
6 Valve bodies and ancillary components
6.1 Material
6.2 General characteristics
6.3 Geometrical characteristics
6.4 Classification and operating conditions
6.5 Mechanical characteristics
6.6 Physical characteristics
6.7 Sealing rings
6.8 Adhesives
6.9 Performance requirements
6.10 Marking
7 Fitness for purpose of the system
Annex A (informative) - Guidance for installation
A.1 Definitions, symbols and abbreviations
A.2 Parameters influencing the design
A.3 Hydraulic properties
A.4 Assembly methods
A.5 Cold bending on site
A.6 Storage, handling and transport of pipes
A.7 Storage, handling and transport of fittings,
valves and ancillaries
A.8 Installation
A.9 Site pressure testing
A.10 Corrosion protection
A.11 Pressure surge
A.12 Repairs
A.13 Pipeline detection
Describes requirements for unplasticized poly(vinyl chloride) (PVC-U) piping systems in the field of buried and above-ground drainage and sewerage under pressure.
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 1456-1 : 2001 | Identical |
NS EN 1456-1 : 2001 | Identical |
NF EN 1456-1 : 2001 | Identical |
UNE-EN 1456-1:2002 | Identical |
BS EN 1456-1:2001 | Identical |
I.S. EN 1456-1:2001 | Identical |
NEN EN 1456-1 : 2001 | Identical |
UNI EN 1456-1 : 2002 | Identical |
NBN EN 1456-1 : 2001 | Identical |
SN EN 1456-1 : 2001 | Identical |
DIN 8061:1994-08 | UNPLASTICIZED POLYVINYL CHLORIDE (PVC-U) PIPES - GENERAL QUALITY REQUIREMENTS AND TESTING |
EN ISO 12162:2009 | Thermoplastics materials for pipes and fittings for pressure applications - Classification, designation and design coefficient (ISO 12162:2009) |
ISO/TR 10358:1993 | Plastics pipes and fittings Combined chemical-resistance classification table |
EN 1452-5 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM |
ENV 1452-6 : DRAFT 2001 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 6: GUIDANCE FOR INSTALLATION |
EN 578 : 1993 | PLASTICS PIPING SYSTEMS - PLASTICS PIPES AND FITTINGS - DETERMINATION OF THE OPACITY |
ISO 1183:1987 | Plastics Methods for determining the density and relative density of non-cellular plastics |
ISO 11922-1:1997 | Thermoplastics pipes for the conveyance of fluids — Dimensions and tolerances — Part 1: Metric series |
ISO 7387-1:1983 | Adhesives with solvents for assembly of PVC-U pipe elements Characterization Part 1: Basic test methods |
EN 921:1994/AC:1995 | PLASTICS PIPING SYSTEMS - THERMOPLASTICS PIPES - DETERMINATION OF RESISTANCE TO INTERNAL PRESSURE AT CONSTANT TEMPERATURE |
EN 773:1999 | General requirements for components used in hydraulically pressurized discharge pipes, drains and sewers |
EN 1452-4 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES AND ANCILLARY EQUIPMENT |
PREN ISO 3126 : DRAFT 1999 | PLASTICS PIPING SYSTEMS - PLASTICS PIPING COMPONENTS - MEASUREMENT AND DETERMINATION OF DIMENSIONS |
ISO 4065:1996 | Thermoplastics pipes Universal wall thickness table |
EN 1452-1 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: GENERAL |
EN 1452-2 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES |
ISO/TR 9080:1992 | Thermoplastics pipes for the transport of fluids — Methods of extrapolation of hydrostatic stress rupture data to determine the long-term hydrostatic strength of thermoplastics pipe materials |
EN 1452-3 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS |
ENV 1046:2001 | Plastics piping and ducting systems - Systems outside building structures for the conveyance of water or sewage - Practices for installation above and below ground |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.