DIN EN 13795:2013-10
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
Hardcopy , PDF
03-07-2021
German, English
01-01-2013
National foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Performance requirements
5 Testing
6 Manufacturing and processing requirements
7 Information to be supplied by the manufacturer
or processor
Annex A (informative) - Details of significant changes
between this European Standard and the
previous edition
Annex B (normative) - Test methods
Annex C (informative) - Prevention of infection in the
operating room
Annex D (informative) - Information on further characteristics
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 93/42/EEC
Bibliography
This standard is included in DIN Handbook 475.
DevelopmentNote |
Supersedes DIN EN 13795-1, DIN EN 13795-2 and DIN EN 13795-3. (06/2011)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 13795:2011+A1:2013 | Identical |
PREN 13795 : DRAFT 2009 | Identical |
DIN HDBK 475 : 2ED 2013 | |
VDI 2083 Blatt 18:2012-01 | Cleanroom technology - Biocontamination control |
VDI 2083 Blatt 9.2:2017-01 | Cleanroom technology - Consumables in the cleanroom |
EN ISO 22610:2006 | Surgical drapes, gowns and clean air suits, used as medical devices, for patients, clinical staff and equipment - Test method to determine the resistance to wet bacterial penetration (ISO 22610:2006) |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
EN 20811:1992 | Textiles - Determination of resistance to water penetration - Hydrostatic pressure test |
EN ISO 9073-11:2004 | Textiles - Test methods for nonwovens - Part 11: Run-off (ISO 9073-11:2002) |
ISO 9237:1995 | Textiles — Determination of the permeability of fabrics to air |
ISO 9073-12:2002 | Textiles — Test methods for nonwovens — Part 12: Demand absorbency |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
EN ISO 9237:1995 | Textiles - Determination of permeability of fabrics to air (ISO 9237:1995) |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 11810-2:2007 | Lasers and laser-related equipment Test method and classification for the laser-resistance of surgical drapes and/or patient-protective covers Part 2: Secondary ignition |
EN 1041:2008+A1:2013 | Information supplied by the manufacturer of medical devices |
EN 14065:2016 | Textiles - Laundry processed textiles - Biocontamination control system |
ISO 22612:2005 | Clothing for protection against infectious agents Test method for resistance to dry microbial penetration |
ISO 11810-1:2005 | Lasers and laser-related equipment Test method and classification for the laser resistance of surgical drapes and/or patient protective covers Part 1: Primary ignition and penetration |
EN 29073-3:1992 | Textiles - Test methods for nonwovens - Part 3: Determination of tensile strength and elongation |
EN ISO 13938-1:1999 | Textiles - Bursting properties of fabrics - Part 1: Hydraulic method for determination of bursting strength and bursting distension (ISO 13938-1:1999) |
ISO 22610:2006 | Surgical drapes, gowns and clean air suits, used as medical devices, for patients, clinical staff and equipment Test method to determine the resistance to wet bacterial penetration |
ISO 11092:2014 | Textiles — Physiological effects — Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test) |
ISO 9073-11:2002 | Textiles — Test methods for nonwovens — Part 11: Run-off |
ISO 9073-10:2003 | Textiles — Test methods for nonwovens — Part 10: Lint and other particles generation in the dry state |
EN ISO 9073-10:2004 | Textiles - Test methods for nonwovens - Part 10: Lint and other particles generation in the dry state (ISO 9073-10:2003) |
ISO 139:2005 | Textiles — Standard atmospheres for conditioning and testing |
EN ISO 11810-1:2009 | Lasers and laser-related equipment - Test method and classification for the laser resistance of surgical drapes and/or patient protective covers - Part 1: Primary ignition and penetration (ISO 11810-1:2005) |
ISO 13938-1:1999 | Textiles Bursting properties of fabrics Part 1: Hydraulic method for determination of bursting strength and bursting distension |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
EN ISO 9073-12:2004 | Textiles - Test methods for nonwovens - Part 12: Demand absorbency (ISO 9073-12:2002) |
EN 980:2008 | Symbols for use in the labelling of medical devices |
EN ISO 11810-2:2009 | Lasers and laser-related equipment - Test method and classification for the laser-resistance of surgical drapes and/or patient-protective covers - Part 2: Secondary ignition (ISO 11810-2:2007) |
EN ISO 22612:2005 | Clothing for protection against infectious agents - Test method for resistance to dry microbial penetration (ISO 22612:2005) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.