DIN EN 13463-1:2009-07
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
NON-ELECTRICAL EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES - PART 1: BASIC METHOD AND REQUIREMENTS
Hardcopy , PDF
12-01-2016
English
01-01-2009
Vorwort
Einleitung
1 Anwendungsbereich
2 Normative Verweisungen
3 Begriffe
4 Gerätekategorien und Explosionsgruppen
4.1 Gerätekategorie
4.2 Explosionsgruppen (Unterteilungen)
4.3 Spezifische explosionsfähige
Atmosphären
5 Zündgefahrenbewertung
5.1 Allgemeine Anforderungen
5.2 Ablauf der Zündgefahrenbewertung
6 Bewertung von möglichen Zündquellen
6.1 Allgemeines
6.2 Heisse Oberflächen
6.3 Flammen und heisse Gase (einschliesslich
heisse Partikel)
6.4 Mechanisch erzeugte Funken
6.5 Elektrische Zündquellen
6.6 Elektrische Streuströme, kathodischer
Korrosionsschutz
6.7 Statische Elektrizität
6.8 Blitzschlag
6.9 Elektromagnetische Hochfrequenzwellen (RF)
von 10[4] Hz bis 3 x 10[12] Hz
6.10 Elektromagnetische Wellen von 3 x 10[11]
Hz bis 3 x 10[15] Hz
6.11 Ionisierende Strahlung
6.12 Ultraschall
6.13 Adiabatische Kompression und Druckwellen
6.14 Exotherme Reaktionen, einschliesslich
Selbstentzündung von Stäuben
7 Zusätzliche Betrachtungen
7.1 Staubablagerungen und anderes Material in
den Spalten sich bewegender Teile
7.2 Zeit zum Öffnen von Gehäusen
7.3 Nichtmetallische Teile der Geräte
7.4 Abnehmbare Teile
7.5 Zum Verkleben verwendete Materialien
7.6 Lichtdurchlässige Teile
8 Verifizierung und Prüfungen
8.1 Allgemeines
8.2 Bestimmung der maximalen Oberflächentemperatur
8.3 Entflammbarkeitsprüfung
8.4 Mechanische Prüfungen
8.5 Zusätzliche Prüfungen von nichtmetallischen
Geräteteilen, die für den Explosionsschutz
von Bedeutung sind
9 Dokumentation und Bedienungsanleitung
9.1 Technische Dokumentation des Herstellers
9.2 Bedienungsanleitung
9.3 Kennzeichnung
9.4 Beispiele für die vollständige Kennzeichnung
(informativ)
Anhang A (normativ) Verfahrensweise bei der Festlegung
der Kategorie
Anhang B (informativ) Erläuterung des Verfahrens der
Zündgefahrenbewertung
Anhang C (informativ) Beispiele der Zündgefahrenbewertung
Anhang D (informativ) Aufladungsprüfungenvon nicht
leitenden Materialien
Anhang E (informativ) Beispiel einer Prüfeinrichtung für
die Schlagfestigkeitsprüfung
Anhang F (normativ) Prüfeinrichtung für die
Schlagzündprüfung
Anhang G (informativ) Vernünftigerweise vorhersehbarer
Fehlgebrauch der bei der Zündgefahrenbewertung
zu berücksichtigen ist
Anhang H (informativ) Massgebliche Änderungen
zwischen dieser Europäischen Norm und der
vorherigen Ausgabe
Anhang ZA (informativ) Zusammenhang zwischen dieser
Europäischen Norm und den grundlegenden
Anforderungen der EG-Richtlinie 94/9/EG
Literaturhinweise
Bilder
Tabellen
This standard is included in DIN HDBK 412.
DevelopmentNote |
A transition period, as set out in DIN EN ISO 80079-36 issue 12-2016, exists until 31-10-2019. (04/2017)
|
DocumentType |
Standard
|
Pages |
75
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 13463-1:2009 | Identical |
SN EN 13463-1 : 2009 | Identical |
UNI EN 13463-1 : 2009 | Identical |
NEN EN 13463-1 : 2009 | Identical |
NF EN 13463-1 : 2009 | Identical |
NS EN 13463-1 : 2009 | Identical |
I.S. EN 13463-1:2009 | Identical |
NBN EN 13463-1 : 2009 | Identical |
BS EN 13463-1:2009 | Identical |
UNE-EN 13463-1:2011 | Identical |
VDI 2263 Blatt 5:2014-10 | Dust fires and dust explosions - Hazards, assessment, protective measures - Explosion protection in fluidized bed dryers |
VDI 2263 Blatt 8:2008-12 | Dust fires and dust explosions - Hazards - Assessment - Protective measures - Fire and explosion protection on elevators |
VDI/VDE 3844:2014-01 | Industrial process control valves - Actuators for control valves |
VDI 2263 Blatt 8.1:2011-03 | Dust fires and dust explosions - Hazards - assessment - protective measures - Fire and explosion protection on elevators - Examples |
VDI 2262 Blatt 1:2013-06 | Workplace air - Reduction of exposure to air pollutants - Legal principles, terms and definitions, basic organisational measures for industrial safety and environmental protection |
VDI 2263 Blatt 6:2017-08 | Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in dust extracting installations |
VDI 3476 Blatt 2:2010-01 | Waste gas cleaning - Catalytic waste gas cleaning methods - Oxidative processes |
VDE 0170-12-2 : 2001-05 | GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST |
DIN EN 50303 : 2001-05 | GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST |
DIN HDBK 412 : 1ED 2015 |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
ISO 6507-1:2005 | Metallic materials Vickers hardness test Part 1: Test method |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 60079-26:2015 | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
ISO 6507-4:2005 | Metallic materials Vickers hardness test Part 4: Tables of hardness values |
EN 582:1993 | Thermal spraying - Determination of tensile adhesive strength |
EN 60079-1:2014 | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC TR 60079-20:1996 | Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 12874 : 2001 | FLAME ARRESTERS - PERFORMANCE REQUIREMENTS, TEST METHODS AND LIMITS FOR USE |
EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
EN 13463-6:2005 | Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source 'b' |
EN 60079-28:2015 | Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation |
ISO 281:2007 | Rolling bearings Dynamic load ratings and rating life |
EN 14986:2017 | Design of fans working in potentially explosive atmospheres |
EN 1755:2015 | Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres |
EN 13463-8:2003 | Non-electrical equipment for potentially explosive atmospheres - Part 8: Protection by liquid immersion 'k' |
EN 61241-1:2004/corrigendum Dec. 2006 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES "TD" |
EN 1127-2:2014 | Explosive atmospheres - Explosion prevention and protection - Part 2: Basic concepts and methodology for mining |
EN 15198:2007 | Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres |
IEC 61241-1:2004 | Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD" |
EN 13463-2:2004 | Non-electrical equipment for use in potentially explosive atmospheres - Part 2: Protection by flow restricting enclosure 'fr' |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
ISO 12100-1:2003 | Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology |
EN 14522:2005 | Determination of the auto ignition temperature of gases and vapours |
EN 13463-5:2011 | Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c' |
EN 13463-3:2005 | Non-electrical equipment for use in potentially explosive atmospheres - Part 3: Protection by flameproof enclosure 'd' |
IEC TR 60079-12:1978 | Electrical apparatus for explosive gas atmospheres - Part 12:Classification of mixtures of gases of vapours with air accordingto their maximum experimental safe gaps and minimum ignitingcurrents |
EN 50303:2000 | Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust |
IEC 60079-26:2014 RLV | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
CLC/TR 50404:2003 | Electrostatics - Code of practice for the avoidance of hazards due to static electricity |
ISO 1817:2015 | Rubber, vulcanized or thermoplastic Determination of the effect of liquids |
1994/9/EC : 1994 | DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
EN 60079-2:2014/AC:2015 | EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P' (IEC 60079-2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.