• There are no items in your cart

DIN EN 1279-1:2015-08 (Draft)

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION

Available format(s)

Hardcopy , PDF

Superseded date

03-07-2021

Language(s)

German

Published date

01-01-2015

US$95.61
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Definitions
4 Insulating glass unit systems
   4.1 General
   4.2 The glass panes/components
   4.3 Cavity fillings
   4.4 Cavity inserts
   4.5 Shapes
   4.6 Curved insulating glass units
5 Requirements
   5.1 Conformity with the definition of insulating
        glass units
   5.2 Optical and visual quality of the glazed unit
   5.3 Dimensions and dimensional tolerances
        5.3.1 General
        5.3.2 Height and width of the unit.
        5.3.3 Thickness tolerances along the periphery
               of the unit
Annex A (normative) System description of insulating glass
        units
   A.1 General content of the system description
   A.2 The normative part of the system description
        A.2.1 Normative sub parts of the system description
        A.2.2 The component descriptions
        A.2.3 The processed edge seal description
   A.3 The informative part of the system description
   A.4 Test samples representative of the system description
Annex B (normative) Tables of possibilities to substitute
        materials and components, and of possible changes
        within components
Annex C (informative) Optical and visual quality of the
        glazed unit
   C.1 Interface colouration (Brewster's fringes, Newton rings)
        C.1.1 Brewster's fringes
        C.1.2 Newton rings
        C.1.3 Others
   C.2 Glass deflection due to variations in temperature and
        barometric pressure
   C.3 External condensation
   C.4 Natural colour of clear glass
Bibliography

Defines insulating glass units, and ensures by means of the evaluation of conformity to this standard that over time: - energy savings are made because the U-value and solar factor do not change significantly; - health is preserved because sound reduction and vision do not change significantly; - safety is provided because mechanical resistance does not change significantly.

DevelopmentNote
DRAFT 2015 issued in August 2015. (08/2015)
DocumentType
Draft
Pages
84
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded

DIN 18361:2016-09 GERMAN CONSTRUCTION CONTRACT PROCEDURES (VOB) - PART C: GENERAL TECHNICAL SPECIFICATIONS IN CONSTRUCTION CONTRACTS (ATV) - GLAZING WORKS
DIN 18008-1:2010-12 GLASS IN BUILDING - DESIGN AND CONSTRUCTION RULES - PART 1: TERMS AND GENERAL BASES

EN 572-3:2012 Glass in building - Basic soda lime silicate glass products - Part 3: Polished wired glass
EN 12337-1:2000 Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description
EN 13024-1:2011 Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description
EN 1748-2-1:2004 Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties
PREN 14179-1 : DRAFT 2014 GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION
EN 1096-1:2012 Glass in building - Coated glass - Part 1: Definitions and classification
EN ISO 12543-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011)
EN 1863-1:2011 Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description
EN ISO 12543-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011)
EN 1279-6:2002 Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests
EN 572-6:2012 Glass in building - Basic soda lime silicate glass products - Part 6: Wired patterned glass
EN 572-2:2012 Glass in building - Basic soda lime silicate glass products - Part 2: Float glass
EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances
EN 12150-1:2015 Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description
EN 1279-4:2002 Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals
EN 1748-1-1:2004 Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties
PREN 14178-1 : DRAFT 2017 GLASS IN BUILDING - BASIC ALKALINE EARTH SILICATE GLASS PRODUCTS - PART 1: FLOAT GLASS
EN 572-4:2012 Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass
EN 1279-2:2002 Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration
EN 572-1:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties
EN 572-5:2012 Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass
EN 572-8:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes
EN ISO 12543-5:2011 Glass in building - Laminated glass and laminated safety glass - Part 5: Dimensions and edge finishing (ISO 12543-5:2011)
EN ISO 12543-1:2011 Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.