DIN EN 1020:2010-05
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
NON-DOMESTIC FORCED CONVECTION GAS-FIRED AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW INCORPORATING A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR OR COMBUSTION PRODUCTS
Hardcopy , PDF
03-07-2021
English
01-01-2010
Foreword
1 Scope
2 Normative references
3 Definitions
3.1 Appliance and its constituent parts
3.2 Adjusting, control and safety devices
3.3 Operation of the appliance
3.4 Gases
3.5 Conditions of operation and measurement
3.6 Marking of the appliance and packaging
3.7 Classification
3.7.1 Classification of gases
3.7.2 Classification of appliances
4 Construction and design requirements
4.1 General
4.1.1 Conversion to different gases
4.1.2 Materials and method of construction
4.1.3 Accessibility for maintenance and use
4.1.4 Thermal insulation
4.1.5 Gas connection
4.1.6 Soundness
4.1.7 Supply of combustion air and evacuation of
combustion products
4.1.8 Supply and distribution of air for space
heating
4.1.9 Checking the state of operation
4.1.10 Electrical equipment
4.1.11 Operational safety in the event of
fluctuation, interruption and restoration
of the auxiliary energy
4.1.12 Motors and fans
4.2 Adjusting, control and safety devices
4.2.1 General
4.2.2 Gas rate adjusters and range-rating devices
4.2.3 Aeration adjusters
4.2.4 Manual controls
4.2.5 Governors
4.2.6 Multifunctional controls
4.2.7 Flame supervision devices
4.2.8 Automatic shut-off valves
4.2.9 Burner control systems
4.2.10 Gas strainers
4.3 Ignition devices
4.3.1 General
4.3.2 Ignition device for the main burner
4.3.3 Ignition burners
4.4 Transportation of combustion air and/or
flue gases
4.4.1 Type B14 appliances
4.4.2 All appliances except Type B14
4.5 Flame supervision system
4.5.1 Type B14 appliances
4.5.2 All appliances except Type B14
4.6 Start-gas flame establishment
4.6.1 Type B14 appliances
4.6.2 All appliances except Type B14
4.7 Main flame establishment
4.7.1 Type B14 appliances
4.7.2 All appliances except Type B14
4.8 Main burner
4.9 Facility for remote control
4.10 Thermostats and control of air temperature
4.10.1 General requirements
4.10.2 Overheat cut-off device
4.10.3 Overheat control device
4.10.4 Overheat cut-off control device
4.10.5 Fans delay controls
4.10.6 Sensors
4.11 Gas pressure test points
4.12 Combustion chamber pressure reliefs
4.13 Facilities for commissioning and testing
4.14 Additional requirements for appliances designed
for outdoor installation
4.14.1 General
4.14.2 Air inlets
4.14.3 Access panels and doors
4.14.4 Dimensions of openings
4.14.5 Fixing screws
5 Operational requirements
5.1 Safety of operation
5.1.1 Soundness
5.1.2 Heat inputs
5.1.3 Limiting temperatures
5.1.4 Ignition, cross-lighting, flame stability
5.1.5 Combustion
5.1.6 Overheat cut-off device
5.1.7 Heat exchanger thermal cycling
5.1.8 Effectiveness of the pre-purge
5.1.9 Weather resistance
5.2 Efficiency
6 Test methods
6.1 General
6.1.1 Characteristics of test gases:
reference and limit gas
6.1.2 Conditions for preparation of the test
gases
6.1.3 Practical application of test gases
6.1.4 Test pressures
6.1.5 Test procedures
6.1.6 General test conditions
6.2 Construction and design
6.2.1 Automatic burner control systems
(manually operated devices)
6.2.2 Ignition opening time
6.2.3 Extinction safety time
6.2.4 Safety time
6.3 Safety of operation
6.3.1 Soundness
6.3.2 Heat inputs
6.3.3 Limiting temperatures
6.3.4 Ignition, cross-lighting, flame stability
6.3.5 Combustion
6.3.6 Overheat cut-off device
6.3.7 Heat exchanger thermal cycling
6.3.8 Effectiveness of the pre-purge
6.3.9 Weather resistance
6.4 Efficiency
6.4.1 General conditions of test
6.4.2 Test conditions
6.4.3 Test procedure
6.4.4 Accuracy of measurement
6.4.5 Calculation of efficiency
6.4.6 Supplementary test for appliances with
a modulating or high/low control
7 Marking and instructions
7.1 Marking of the appliance
7.1.1 Description
7.1.2 Data plate
7.1.3 Other marking
7.2 Marking of the packaging
7.3 Utilization of symbols on the appliance and
packaging
7.3.1 Electrical supply
7.3.2 Type of gas
7.3.3 Gas supply pressure
7.3.4 Country of destination
7.3.5 Category
7.3.6 Other information
7.3.7 Emissions
7.4 Instructions
7.4.1 General
7.4.2 Technical instructions for installation and
adjustment
7.4.3 Instructions for use and maintenance
7.4.4 Instructions for servicing
7.4.5 Lighting instructions
7.4.6 Instructions for conversion
Annex A (informative) National situations
Annex B (normative) Classification according to the
evacuation of the combustion products
Annex C (normative) Requirements and test methods for
separate air supply and combustion products
evacuation ducts
Annex D (normative) Requirements for high-voltage
ignition circuits
Annex E (informative) Facilities for commissioning and
testing (see 4.13)
Annex F (informative) Means of identification of the
various types of gas in force in the various
countries
Annex G (informative) Requirements in EN 1020 which
relate to the design and construction of forced
draught burners covered in EN 676:1996
Annex H (informative) A-deviations
Annex J (normative) Special national conditions
Annex K (informative) Calculation of conversions of NO[x]
Annex ZA (informative) Clauses of this European Standard
addressing requirements or provisions of
EU Directives
Defines the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters having a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as 'appliances'.
DocumentType |
Standard
|
Pages |
154
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
Standards | Relationship |
NEN EN 1020 : 2009 | Identical |
UNI EN 1020 : 2009 | Identical |
NBN EN 1020 : 2010 | Identical |
UNE-EN 1020:2010 | Identical |
NS EN 1020 : 2009 | Identical |
NF EN 1020 : 2010 | Identical |
EN 1020:2009 | Identical |
SN EN 1020 : 2010 | Identical |
I.S. EN 1020:2009 | Identical |
BS EN 1020:2009 | Identical |
EN 1859:2009+A1:2013 | Chimneys - Metal chimneys - Test methods |
IEC 60335-2-102:2004+AMD1:2008+AMD2:2012 CSV | Household and similar electrical appliances - Safety - Part 2-102:Particular requirements for gas, oil and solid-fuel burning appliances having electrical connections |
IEC 60730-2-9:2015 RLV | Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls |
ISO 7005-2:1988 | Metallic flanges — Part 2: Cast iron flanges |
ISO 6976:2016 | Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from composition |
EN 10226-2:2005 | Pipe threads where pressure tight joints are made on the threads - Part 2: Taper external threads and taper internal threads - Dimensions, tolerances and designation |
EN 60584-2:1993 | Thermocouples - Part 2: Tolerances |
EN 60730-2-9:2010 | Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls |
EN 12067-1 : 98 AMD 1 2003 | GAS/AIR RATIO CONTROLS FOR GAS BURNERS AND GAS BURNING APPLIANCES - PART 1: PNEUMATIC TYPES |
ISO 7005-3:1988 | Metallic flanges Part 3: Copper alloy and composite flanges |
EN ISO 3166-1:2014 | Codes for the representation of names of countries and their subdivisions - Part 1: Country codes (ISO 3166-1:2013) |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 161:2011+A3:2013 | Automatic shut-off valves for gas burners and gas appliances |
ISO 1182:2010 | Reaction to fire tests for products Non-combustibility test |
EN ISO 228-1:2003 | Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) |
ISO 7-1:1994 | Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
EN 125:2010+A1:2015 | Flame supervision devices for gas burning appliances - Thermoelectric flame supervision devices |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 126:2012 | Multifunctional controls for gas burning appliances |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
EN 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
CR 1404:1994 | Determination of emissions from appliances burning gaseous fuels during type-testing |
IEC 60730-2-1:1989 | Automatic electrical controls for household and similar use. Part 2: Particular requirements for electrical controls for electrical household appliances |
EN 60335-2-102:2016 | Household and similar electrical appliances - Safety - Part 2-102: Particular requirements for gas, oil and solid-fuel burning appliances having electrical connections |
EN 60730-2-1 : 97 AMD 11 2005 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-1: PARTICULAR REQUIREMENTS FOR ELECTRICAL CONTROLS FOR ELECTRICAL HOUSEHOLD APPLIANCES |
ISO 3166-1:2013 | Codes for the representation of names of countries and their subdivisions Part 1: Country codes |
EN 61058-1:2002/A2:2008 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
EN 298:2012 | Automatic burner control systems for burners and appliances burning gaseous or liquid fuels |
ISO 7005-1:2011 | Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN ISO 6976:2016 | Natural gas - Calculation of calorific values, density, relative density and Wobbe indices from composition (ISO 6976:2016) |
EN 10226-1:2004 | Pipe threads where pressure tight joints are made on the threads - Part 1: Taper external threads and parallel internal threads - Dimensions, tolerances and designation |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
EN 88-1:2011+A1:2016 | Pressure regulators and associated safety devices for gas appliances - Part 1: Pressure regulators for inlet pressures up to and including 50 kPa |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
EN 257:2010 | Mechanical thermostats for gas-burning appliances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.