• There are no items in your cart

DIN 57636-22 : 1984

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

LOW-VOLTAGE FUSES - PART 22: H.R.C. FUSES; H.R.C. FUSES UP TO 1250 A AND 1000 V A.C. FOR PROTECTION OF EQUIPMENT

Withdrawn date

10-22-2017

Published date

01-12-2013

Sorry this product is not available in your region.

1 Anwendungsbereich
2 Begriffe
  2.1 NH-Sicherungsleiste
  2.2 Schlagvorrichtung
  2.3 Schaltzustandsgeber
  2.4 Auslösevorrichtung
  2.5 Einschwenk- oder Einsetzvorrichtung
  2.6 Grifflaschen
  2.7 Bemessungsstrom
3 Betriebsbedingungen
4 Klassifikation
5 Charakteristische Merkmale
  5.1 Spannungen
  5.2 Ströme
  5.3 Kennlinien
  5.4 Selektivität
  5.5 Kennlinienbeständigkeit
  5.6 Erwärmung und Verlustleistung
  5.7 Ausschaltvermögen
6 Anforderungen
  6.1 Allgemeines
  6.2 Unverwechselbarkeit
  6.3 Berührungsschutz
  6.4 Kriech-, Luftstrecken und Abstände
  6.5 Leiteranschlüsse
  6.6 NH-Sicherungsunterteile bzw NH-Sicherungsleisten
  6.7 Sicherungseinsätze
  6.8 Kontaktstücke
  6.9 Werkstoffe
  6.10 Isolierteile
  6.11 Kennzeichnung
7 Prüfung
  7.1 Allgemeines
  7.2 Masse, Kennzeichnung, Kriech- und Luftstrecken,
       Abstände
  7.3 Kriechstromfestigkeit
  7.4 Spannungsfestigkeit und Isolationswiderstand
  7.5 Erwärmung und Verlustleistung
  7.6 Zeit/Strom-Verhalten
  7.7 Kennlinienbeständigkeit
  7.8 Wärme-, Schlagfestigkeit und Feuersicherheit
  7.9 Widerstandsfähigkeit gegen Korrosion (Rost)
  7.10 Mechanische Festigkeit und Montierbarkeit
  7.11 Ausschaltvermögen und Schaltspannung
  7.12 Selektivität
  7.13 Funktion des Anzeigers und der Schlagvorrichtung
  7.14 Alterungsbeständigkeit der Kontakte
  7.15 Dynamische Kurzschlussfestigkeit von
       NH-Sicherungsunterteilen und NH-Sicherungsleisten
  7.16 Alterungsbeständigkeit von Leiteranschlussklemmen an
       NH-Sicherungsunterteilen und NH-Sicherungsleisten
Bilder
Zitierte Normen und andere Unterlagen
Erläuterungen

Diese Norm gilt im Rahmen von DIN 57636 Teil 1/VDE 0636 Teil 1 für Niederspannungs-HochleistungsSicherungen (kurz NH-Sicherungen) nach DIN 43620 Teil 1, Teil 3 und Teil 4 für den Anlagenschutz, d.h. für Schaltgeräteschutz aM, Bergbauanlagenschutz gB und Transformatorenschutz gTr; sie gilt ferner für NH-Sicherungsleisten nach DIN 43623. Sie gilt auch für genormte NH-Sicherungseinsätze mit Schlagvorrichtung sowie für NH-Sicherungsunterteile und NH-Sicherungsleisten mit Auslösevorrichtungen.

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Withdrawn

Standards Relationship
VDE 0636-22 : 1984 Corresponds
DIN VDE 0636-22 : 1984 Corresponds

DIN VDE 0636-41 : 1983 LOW-VOLTAGE FUSES - PART 41: D0-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 380 V A.C. 250 V D.C.
DIN 57636-21 : 1984 LOW-VOLTAGE FUSES - PART 21: H.R.C. FUSES; PROTECTION OF CABLES AND CORDS UP TO 1250 A AND 500 V A.C., 440 V D.C. AND 660 V A.C.
DIN 57636-1 : 1983 LOW-VOLTAGES FUSES - PART 1: GENERAL REQUIREMENTS
DIN 57636-31 : 1983 LOW VOLTAGE FUSES - PART 31: D-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 500 V AND/OR UP TO 63 A 660 V A.C. 600 V D.C.
DIN 57636-41 : 1983 LOW-VOLTAGE FUSES - PART 41: D0-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 380 V A.C. 250 V D.C.
DIN VDE 0636-1 : 1983 LOW-VOLTAGES FUSES - PART 1: GENERAL REQUIREMENTS

DIN 931-1:1987-09 M 1,6 TO M 39 HEXAGON HEAD BOLTS - PRODUCT GRADES A AND B
DIN 57636-21 : 1984 LOW-VOLTAGE FUSES - PART 21: H.R.C. FUSES; PROTECTION OF CABLES AND CORDS UP TO 1250 A AND 500 V A.C., 440 V D.C. AND 660 V A.C.
DIN 42523:1987-05 TRANSFORMERS - ENCAPSULATED-WINDING DRY-TYPE TRANSFORMERS - 50 HZ, 100 TO 2500 KVA
DIN 42500:1984-09 THREE-PHASE OIL-IMMERSED PUBLIC DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA, U[M] = 24 KV
VDE 0636-23 : 1984 LOW-VOLTAGE FUSES - LV HRC FUSES FOR PROTECTION OF SEMICONDUCTORS UP TO 1600 A & UP TO 3000 V
DIN IEC 60068-2-3:1986-12 ELECTRICAL ENGINEERING; BASIC ENVIRONMENTAL TESTING PROCEDURES; TESTS; TEST CA: DAMP HEAT, STEADY STATE
DIN 43623:1981-05 THREE-POLE FUSE-BASE RACKS 660 V, 100 TO 630 A, FOR L.V.H.R.C. FUSES, FOR BUSBAR MOUNTING
VDE 0110B : 1979 SPECIFICATIONS FOR CLEARANCES AND CREEPAGE DISTANCES IN ELECTRICAL EQUIPMENT; AMENDMENT TO VDE 0110/11.72
DIN 267-11:1980-01 FASTENERS - TECHNICAL DELIVERY CONDITIONS (WITH ADDITIONS TO ISO 3506) - CORROSION-RESISTANT STAINLESS STEEL FASTENERS
DIN 53480 : 1976 VDE-BESTIMMUNG FUER ELEKTRISCHE PRUEFUNGEN VON ISOLIERSTOFFEN; KRIECHSTROMFESTIGKEIT
DIN 57636-31 : 1983 LOW VOLTAGE FUSES - PART 31: D-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 500 V AND/OR UP TO 63 A 660 V A.C. 600 V D.C.
DIN 57680-4 : 1980 PERSONNEL PROTECTIVE EQUIPMENT, PROTECTIVE AND APPARATUS FOR WORK ON ENERGIZED SYSTEMS UP TO 1000 V; PART 4: FUSE HANDLES FOR LOW-TENSION HRC-FUSES
DIN 57636-23 : 1984 NIEDERSPANNUNGSSICHERUNGEN; NH-SYSTEM, HALBLEITERSCHUTZSICHERUNGEN BIS 1600 A UND BIS 3000 V
VDE 0303-1 : 1984 METHOD FOR DETERMINING THE COMPARATIVE AND THE PROOF TRACKING INDICES OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS
DIN 43620-4:1981-09 LOW VOLTAGE HIGH-RUPTURING-CAPACITY FUSES WITH BLADE CONTACTS 500 AND 660 V A.C. AND 440 D.C. - REPLACEMENT HANDLE FOR THE SIZES 00 UP TO 3 - DIMENSIONS OF THE ENGAGING PART
DIN 42524:1987-05 TRANSFORMERS - NON-ENCAPSULATED-WINDING DRY-TYPE TRANSFORMERS - 50 HZ, 100 TO 1600 KVA
DIN 57636-41 : 1983 LOW-VOLTAGE FUSES - PART 41: D0-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 380 V A.C. 250 V D.C.
DIN 46206-2:1971-06 SUPPLY-TERMINALS FOR ELECTRICAL EQUIPMENT >= 40 A, CONNECTIONS WITH RECTANGULAR CROSS-SECTION, BASIC DIMENSIONS AND COORDINATION
DIN 43620-1:1984-05 LOW VOLTAGE HIGH RUPTURING CAPACITY FUSES WITH BLADE CONTACTS; LV HRC FUSE LINKS FOR 500 & 660 V A.C. & 440 V D.C.
DIN 43620-3:1984-05 LOW-VOLTAGE, HIGH-RUPTURING-CAPACITY FUSES WITH BLADE CONTACTS; LV HRC FUSE BASES FOR LV HRC FUSE LINKS FOR 500 AND 660 V A.C. AND 440 V D.C.
VDE 0636-31 : 2015 Low-voltage fuses Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household or similar applications) – Examples of standardized systems of fuses A to F – National Supplement 1: Rated voltage = AC 690 V and rated voltage = DC 600 V
DIN 57635 : 1984 LOW VOLTAGE FUSES; D-FUSES E 16 UP TO 25 A, 500 V; D-FUSES UP TO 100 A, 750 V; D-FUSES UP TO 100 A, 500 V
DIN 933:1987-09 M 1.6 TO M 52 HEXAGON HEAD SCREWS THREADED UP TO THE HEAD; PRODUCT GRADES A & B
DIN 50018:2013-05 Testing in a saturated atmosphere in the presence of sulfur dioxide
VDE 0110 : 1972 SPECIFICATION FOR CLEARANCES AND CREEPAGE DISTANCES IN ELECTRICAL EQUIPMENT
DIN 57471-2 : 1975 VDE SPECIFICATIONS FOR FIRE RISK TESTING OF ELECTROTECHNICAL PRODUCTS, THEIR SUBASSEMBLIES AND COMPONENTS - GLOW-WIRE TEST
VDE 0635 : 1984 LOW-VOLTAGE FUSES - D-FUSES E 16 UP TO 25 A, 500 V - D-FUSES UP TO 100 A 750 V - D-FUSES UP TO 100 A, 500 V
DIN 57636-1 : 1983 LOW-VOLTAGES FUSES - PART 1: GENERAL REQUIREMENTS
VDE 0636-1 : 2015 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006 + A1:2009 + A2:2014)
VDE 0636-21 : 2015 LOW-VOLTAGE FUSES - PART 2: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - NATIONAL SUPPLEMENT 1: PROTECTION OF SPECIAL ELECTRICAL SYSTEMS
VDE 0636-41 : 1983 LOW-VOLTAGE FUSES - PART 41: D0-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 380 V A.C. 250 V D.C.
VDE 0680-4 : 1980 PERSONNEL PROTECTIVE EQUIPMENT, PROTECTIVE DEVICES & APPARATUS FOR WORK ON ELECTRICALLY ENERGIZED SYSTEMS UP TO 1000V - FUSE HANDLES FOR LOW-TENSION HRC-FUSES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.