DEFSTAN 02-526/1(2000) : 2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
REQUIREMENTS FOR CABLES, ELECTRIC RUBBER INSULATED, LIMITED FIRE HAZARD SHEATHED FOR GENERAL SERVICES CATEGORY 2
Hardcopy , PDF
01-31-2008
English
01-01-2000
SECTION 1 - Scope
SECTION 2 - Related Documents
SECTION 3 - Requirements for Materials
Conductor
Separator tape
Conductor insulation
Tapes
Electrical Screens
Sheath
SECTION 4 - Construction
Identification of cores
Numbered tapes
Colour coding
Laying up of cores
Conductor stranding
Separator Tape
Conductor insulation
Wrapping tapes
Screening
Screen insulation
Braids
Sheathing
Tolerances
SECTION 5 - Tests
General
Scheduled Tests
Electrical tests
Visual examination
Tensile strength and elongation at break
Tear resistance
Dimensions
Thermal ageing
Sheath compatibility
Fire test
Cold elongation test on sheath
Heat shock test on sheath
Hot set test
Screens solder ability test
SECTION 6 - Qualification approval procedure
Definitions
General requirements
Qualification approval testing
Test reports
Qualification approval certificates
SECTION 7 - Quality assurance of products
Procedure
SECTION 8 - Packaging and labeling
End sealing
Packing
Supply on reels
Supply on drums
Dispatch lengths
Annex A - Standard form of report for
qualification approval, production quality
and production routine tests
Annex B - Cable drums
Annex C - Tables of dimensions for rubber
insulated cables
Alphabetical index
Covers the manufacture and testing requirements of rubber insulated Limited Fire Hazard (LFH) sheathed cables for power, lighting, control and communication and instrumentation circuits in Surface Ships and Submarines.
DevelopmentNote |
This is a redesignation of NES 526. (01/2001)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
UK Ministry of Defence Standards
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
DEFSTAN 07-247(PT1)/2(2006) : 2006 | THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS |
DEFSTAN 02-512(PT1)/2(2002) : 2002 | GUIDE TO CABLES, ELECTRICAL AND ASSOCIATED ITEMS - PART 1: GENERAL |
DEFSTAN 02-642/3(2005) : 2005 | REQUIREMENTS FOR AIRCRAFT STARTING AND SERVICING CABLE ASSEMBLIES |
DEFSTAN 02-512(PT3)/2(2003) : 2003 AMD 1 2003 | GUIDE TO CABLES, ELECTRICAL AND ASSOCIATED ITEMS - PART 3: CABLES, ELECTRICAL, ETHYLENE PROPYLENE RUBBER INSULATED AND HALOGEN FREE RUBBER INSULATED, LIMITED FIRE HAZARD OR CHLOROSULPHONATED POLYETHYLENE SHEATHED FOR GENERAL SERVICE |
DEFSTAN 02-512(PT12)/2(2002) : 2002 | GUIDE TO CABLES, ELECTRICAL AND ASSOCIATED ITEMS - PART 12: INDEX TO NATO STOCK NUMBERS AND CABLES MANUFACTURING SPECIFICATIONS FOR CABLES LISTED IN PARTS 2-8 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.