CSA Z15883-4 : 2009 : R2014
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
WASHER-DISINFECTORS - PART 4: REQUIREMENTS AND TESTS FOR WASHER-DISINFECTORS EMPLOYING CHEMICAL DISINFECTION FOR THERMOLABILE ENDOSCOPES
Hardcopy , PDF
08-14-2021
English
01-01-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Performance requirements
5 Mechanical and process requirements
6 Testing for conformity
7 Documentation and inspection
8 Information to be supplied by the manufacturer
9 Marking, labelling and packaging
10 Information to be requested from the purchaser by
the manufacturer
Annex A (informative) - Summary of activities covered
by this Part of ISO 15883
Annex B (normative) - Microbiological testing of the
efficacy of chemical disinfection of the load
Annex C (informative) - Summary of test programmes
Annex D (normative) - Methods for microbiological evaluation
of disinfection of liquid transport system
Annex E (normative) - Tests for microbial contamination of
post-disinfection rinse water
Annex F (informative) - Typical specifications of trumpet
valves and connection ports
Annex G (informative) - Additional notes on microbiological
testing of chemical disinfection processes
Bibliography
Describes the particular requirements, including performance, for washer-disinfectors (WDs) that are intended to be used for cleaning and chemical disinfection of thermolabile endoscopes.
DocumentType |
Standard
|
Pages |
66
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 15883-4:2008 | Identical |
IEC 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
EN 13624:2013 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of fungicidal or yeasticidal activity in the medical area - Test method and requirements (phase 2, step 1) |
ISO 15883-1:2006 | Washer-disinfectors Part 1: General requirements, terms and definitions and tests |
EN 14348:2005 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of mycobactericidal activity of chemical disinfectants in the medical area including instrument disinfectants - Test methods and requirements (phase 2, step 1) |
ISO 11731-2:2004 | Water quality Detection and enumeration of Legionella Part 2: Direct membrane filtration method for waters with low bacterial counts |
EN 1717:2000 | Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow |
ISO 384:2015 | Laboratory glass and plastics ware — Principles of design and construction of volumetric instruments |
EN 12353:2013 | Chemical disinfectants and antiseptics - Preservation of test organisms used for the determination of bactericidal (including Legionella), mycobactericidal, sporicidal, fungicidal and virucidal (including bacteriophages) activity |
EN 13727:2012+A2:2015 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity in the medical area - Test method and requirements (phase 2, step 1) |
ISO/TS 15883-5:2005 | Washer-disinfectors Part 5: Test soils and methods for demonstrating cleaning efficacy |
EN 14562:2006 | Chemical disinfectants and antiseptics - Quantitative carrier test for the evaluation of fungicidal or yeasticidal activity for instruments used in the medical area - Test method and requirements (phase 2, step 2) |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
EN 14476:2013+A1:2015 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of virucidal activity in the medical area - Test method and requirements (Phase 2/Step 1) |
EN 14561:2006 | Chemical disinfectants and antiseptics - Quantitative carrier test for the evaluation of bactericidal activity for instruments used in the medical area - Test method and requirements (phase 2, step 2) |