1 Scope
2 Normative references
3 Terms and definitions
4 Performance requirements
5 Mechanical and process requirements
6 Testing for conformity
7 Documentation and inspection
8 Information to be supplied by the manufacturer
9 Marking, labelling and packaging
10 Information to be requested from the purchaser by
the manufacturer
Annex A (informative) - Summary of activities covered
by this Part of ISO 15883
Annex B (normative) - Microbiological testing of the
efficacy of chemical disinfection of the load
Annex C (informative) - Summary of test programmes
Annex D (normative) - Methods for microbiological evaluation
of disinfection of liquid transport system
Annex E (normative) - Tests for microbial contamination of
post-disinfection rinse water
Annex F (informative) - Typical specifications of trumpet
valves and connection ports
Annex G (informative) - Additional notes on microbiological
testing of chemical disinfection processes
Bibliography
This part of ISO 15883 specifies the particular requirements, including performance, for washer-disinfectors (WDs) that are intended to be used for cleaning and chemical disinfection of thermolabile endoscopes.
DocumentType |
Standard Guideline
|
ISBN |
978-1-55491-119-6
|
Pages |
68
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ISO 15883-4:2008 | Identical |
IEC 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
EN 13624:2013 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of fungicidal or yeasticidal activity in the medical area - Test method and requirements (phase 2, step 1) |
ISO 15883-1:2006 | Washer-disinfectors Part 1: General requirements, terms and definitions and tests |
EN 14348:2005 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of mycobactericidal activity of chemical disinfectants in the medical area including instrument disinfectants - Test methods and requirements (phase 2, step 1) |
ISO 11731-2:2004 | Water quality Detection and enumeration of Legionella Part 2: Direct membrane filtration method for waters with low bacterial counts |
EN 1717:2000 | Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow |
ISO 384:2015 | Laboratory glass and plastics ware — Principles of design and construction of volumetric instruments |
EN 12353:2013 | Chemical disinfectants and antiseptics - Preservation of test organisms used for the determination of bactericidal (including Legionella), mycobactericidal, sporicidal, fungicidal and virucidal (including bacteriophages) activity |
EN 13727:2012+A2:2015 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity in the medical area - Test method and requirements (phase 2, step 1) |
ISO/TS 15883-5:2005 | Washer-disinfectors Part 5: Test soils and methods for demonstrating cleaning efficacy |
EN 14562:2006 | Chemical disinfectants and antiseptics - Quantitative carrier test for the evaluation of fungicidal or yeasticidal activity for instruments used in the medical area - Test method and requirements (phase 2, step 2) |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
EN 14476:2013+A1:2015 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of virucidal activity in the medical area - Test method and requirements (Phase 2/Step 1) |
EN 14561:2006 | Chemical disinfectants and antiseptics - Quantitative carrier test for the evaluation of bactericidal activity for instruments used in the medical area - Test method and requirements (phase 2, step 2) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.