• There are no items in your cart

CSA ISO 8637 : 2012 : INC : AMD 1 : 2015 : R2017

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - HAEMODIALYSERS, HAEMODIAFILTERS, HAEMOFILTERS AND HAEMOCONCENTRATORS

Available format(s)

Hardcopy , PDF

Withdrawn date

08-16-2021

Language(s)

English

Published date

01-01-2017

US$85.74
Excluding Tax where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
6 Labelling
Bibliography

This International Standard specifies requirements for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators, hereinafter collectively referred to as the device, for use in humans

Committee
ISO/TC 150
DevelopmentNote
Supersedes CSA Z8637. (04/2012) French Edition issued on 01/02/2013. (04/2013) Amendment 1 is available separately, see CSA ISO 8637A. AMD 1 2015 is only available in English Version. (11/2015)
DocumentType
Standard
ISBN
978-1-55491-882-9
Pages
42
ProductNote
Reconfirmed EN
PublisherName
Canadian Standards Association
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
ISO 8637:2010 Identical

ISO 11137-1:2006 Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
ISO 15223-2:2010 Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation
ISO/TS 17665-2:2009 Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1
ISO 8638:2010 Cardiovascular implants and extracorporeal systems Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO 11135-1:2007 Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
ISO 11137-3:2017 Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control
ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
ISO/TS 11135-2:2008 Sterilization of health care products Ethylene oxide Part 2: Guidance on the application of ISO 11135-1
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings
ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.