• Shopping Cart
    There are no items in your cart

CSA E61347.1 :2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS

Available format(s)

Hardcopy , PDF

Superseded date

07-17-2021

Language(s)

English

Published date

01-01-2013

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Terminals
9 Provisions for protective earthing
10 Protection against accidental contact with live parts
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Construction
16 Creepage distances and clearances
17 Screws, current-carrying parts and connections
18 Resistance to heat, fire and tracking
19 Resistance to corrosion
Annex A (normative) - Test to establish whether a conductive
        part is a live part which may cause an electric
        shock
Annex B (normative) - Particular requirements for thermally
        protected lamp controlgear
Annex C (normative) - Particular requirements for electronic
        lamp controlgear with means of protection against
        overheating
Annex D (normative) - Requirements for carrying out the
        heating tests of thermally protected lamp controlgear
Annex E (normative) - Use of consist S other than 4500 in
        t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of the
        values of pulse voltages
Annex H (normative) - Tests
Bibliography

Defines general electrical safety requirements for certain products.

DocumentType
Standard
Pages
148
ProductNote
Reconfirmed EN
PublisherName
Canadian Standards Association
Status
Superseded

ANSI C82.5 : 2016 LAMP BALLASTS - HIGH-INTENSITY DISCHARGE AND LOW-PRESSURE SODIUM LAMPS
IEC 60598-2-10:2003 Luminaires - Part 2-10: Particular requirements - Portable luminaires for children
IEC TS 60479-1:2005+AMD1:2016 CSV Effects of current on human beings and livestock - Part 1: Generalaspects
IEC 60598-2-23:1996+AMD1:2000 CSV Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps
IEC 60598-2-17:2017 Luminaires - Part 2-17: Particular requirements - Luminaires for stage lighting, television and film studios (outdoor and indoor)
ANSI C78.81:2016 American National Standard for Electric Lamps—Double-Capped Fluorescent Lamps—Dimensional and Electrical Characteristics
CSA C22.2 No. 0.4 : 2004(R2013) BONDING OF ELECTRICAL EQUIPMENT
IEC 60216-4-2:2000 Electrical insulating materials - Thermal endurance properties - Part 4-2: Ageing ovens - Precision ovens for use up to 300 °C
IEC 60598-2-20:2014 Luminaires - Part 2-20: Particular requirements - Lighting chains
IEC 60216-4-1:2006 Electrical insulating materials - Thermal endurance properties - Part 4-1: Ageing ovens - Single-chamber ovens
IEC 60598-2-19:1981 Luminaires. Part 2: Particular requirements. Section Nineteen: Air-handling luminaires (safety requirements)
IEC 60598-2-5:2015 Luminaires - Part 2-5: Particular requirements - Floodlights
ANSI C78.180:2003(R2016) American National Standard for Electric Lamps—Specifications for Fluorescent Lamp Starters
IEC 60598-2-6:1994 Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps
IEC 60216-2:2005 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
IEC 60598-2-8:2013 Luminaires - Part 2-8: Particular requirements - Handlamps
IEC 61047:2004 DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV Lamp controlgear - Part 2-1: Particular requirements for startingdevices (other than glow starters)
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements
IEC 60598-2-3:2002+AMD1:2011 CSV Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
IEC 60216-4:1980 Guide for the determination of thermal endurance properties of electrical insulating materials - Part 4: Instructions for calculating the thermal endurance profile
ANSI C82.3-2016 American National Standard for Reference Ballasts for Fluorescent Lamps
IEEE 101 : 1987 GUIDE FOR THE STATISTICAL ANALYSIS OF THERMAL LIFE TEST DATA
IEC 60598-2-25:1994 Luminaires - Part 2: Particular requirements - Section 25: Luminaires for use in clinical areas of hospitals and health care buildings
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
IEC 60927:2007+AMD1:2013 CSV Auxiliaries for lamps - Starting devices (other than glow starters)- Performance requirements
IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
ANSI C78.1375-1996 400-WATT, M59 SINGLE-ENDED METAL HALIDE LAMPS
IEC 60598-2-24:2013 Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures
IEC 60216-4-3:2000 Electrical insulating materials - Thermal endurance properties - Part 4-3: Ageing ovens - Multi-chamber ovens
IEC 60598-2-2:2011 Luminaires - Part 2-2: Particular requirements - Recessed luminaires
IEC 60216-5:2008 Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
IEC 60155:1993 Glow-starters for fluorescent lamps
IEC 60216-3-1:1990 Guide for the determination of thermal endurance properties of electrical insulating materials. Part 3: Instructions for calculating thermal endurance characteristics - Section 1: Calculations using mean values of normally distributed complete data
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
IEC TR 60479-3:1998 Effects of current on human beings and livestock - Part 3: Effects of currents passing through the body of livestock
IEC 60216-3-2:1993 Guide for the determination of thermal endurance properties of electrical insulating materials - Part 3: Instructions for calculating thermal endurance characteristics - Section 2: Calculations for incomplete data: proof test results up to and including the median time to end-point (equal test groups)
IEC 60598-2-7:1982 Luminaires. Part 2: Particular requirements. Section Seven: Portable luminaires for garden use
IEC 60598-2-4:2017 Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires
IEC 60216-3:2006 Electrical insulating materials - Thermal endurance properties - Part 3: Instructions for calculating thermal endurance characteristics

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.