CSA E61347.1 :2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS
Hardcopy , PDF
07-17-2021
English
01-01-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Terminals
9 Provisions for protective earthing
10 Protection against accidental contact with live parts
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Construction
16 Creepage distances and clearances
17 Screws, current-carrying parts and connections
18 Resistance to heat, fire and tracking
19 Resistance to corrosion
Annex A (normative) - Test to establish whether a conductive
part is a live part which may cause an electric
shock
Annex B (normative) - Particular requirements for thermally
protected lamp controlgear
Annex C (normative) - Particular requirements for electronic
lamp controlgear with means of protection against
overheating
Annex D (normative) - Requirements for carrying out the
heating tests of thermally protected lamp controlgear
Annex E (normative) - Use of consist S other than 4500 in
t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of the
values of pulse voltages
Annex H (normative) - Tests
Bibliography
Defines general electrical safety requirements for certain products.
DocumentType |
Standard
|
Pages |
148
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
ANSI C82.5 : 2016 | LAMP BALLASTS - HIGH-INTENSITY DISCHARGE AND LOW-PRESSURE SODIUM LAMPS |
IEC 60598-2-10:2003 | Luminaires - Part 2-10: Particular requirements - Portable luminaires for children |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
IEC 60598-2-23:1996+AMD1:2000 CSV | Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps |
IEC 60598-2-17:2017 | Luminaires - Part 2-17: Particular requirements - Luminaires for stage lighting, television and film studios (outdoor and indoor) |
ANSI C78.81:2016 | American National Standard for Electric Lamps—Double-Capped Fluorescent Lamps—Dimensional and Electrical Characteristics |
CSA C22.2 No. 0.4 : 2004(R2013) | BONDING OF ELECTRICAL EQUIPMENT |
IEC 60216-4-2:2000 | Electrical insulating materials - Thermal endurance properties - Part 4-2: Ageing ovens - Precision ovens for use up to 300 °C |
IEC 60598-2-20:2014 | Luminaires - Part 2-20: Particular requirements - Lighting chains |
IEC 60216-4-1:2006 | Electrical insulating materials - Thermal endurance properties - Part 4-1: Ageing ovens - Single-chamber ovens |
IEC 60598-2-19:1981 | Luminaires. Part 2: Particular requirements. Section Nineteen: Air-handling luminaires (safety requirements) |
IEC 60598-2-5:2015 | Luminaires - Part 2-5: Particular requirements - Floodlights |
ANSI C78.180:2003(R2016) | American National Standard for Electric Lamps—Specifications for Fluorescent Lamp Starters |
IEC 60598-2-6:1994 | Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps |
IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
IEC 60598-2-8:2013 | Luminaires - Part 2-8: Particular requirements - Handlamps |
IEC 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV | Lamp controlgear - Part 2-1: Particular requirements for startingdevices (other than glow starters) |
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV | DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements |
IEC 60598-2-3:2002+AMD1:2011 CSV | Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting |
IEC 60216-4:1980 | Guide for the determination of thermal endurance properties of electrical insulating materials - Part 4: Instructions for calculating the thermal endurance profile |
ANSI C82.3-2016 | American National Standard for Reference Ballasts for Fluorescent Lamps |
IEEE 101 : 1987 | GUIDE FOR THE STATISTICAL ANALYSIS OF THERMAL LIFE TEST DATA |
IEC 60598-2-25:1994 | Luminaires - Part 2: Particular requirements - Section 25: Luminaires for use in clinical areas of hospitals and health care buildings |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60927:2007+AMD1:2013 CSV | Auxiliaries for lamps - Starting devices (other than glow starters)- Performance requirements |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
ANSI C78.1375-1996 | 400-WATT, M59 SINGLE-ENDED METAL HALIDE LAMPS |
IEC 60598-2-24:2013 | Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures |
IEC 60216-4-3:2000 | Electrical insulating materials - Thermal endurance properties - Part 4-3: Ageing ovens - Multi-chamber ovens |
IEC 60598-2-2:2011 | Luminaires - Part 2-2: Particular requirements - Recessed luminaires |
IEC 60216-5:2008 | Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
IEC 60216-3-1:1990 | Guide for the determination of thermal endurance properties of electrical insulating materials. Part 3: Instructions for calculating thermal endurance characteristics - Section 1: Calculations using mean values of normally distributed complete data |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC TR 60479-3:1998 | Effects of current on human beings and livestock - Part 3: Effects of currents passing through the body of livestock |
IEC 60216-3-2:1993 | Guide for the determination of thermal endurance properties of electrical insulating materials - Part 3: Instructions for calculating thermal endurance characteristics - Section 2: Calculations for incomplete data: proof test results up to and including the median time to end-point (equal test groups) |
IEC 60598-2-7:1982 | Luminaires. Part 2: Particular requirements. Section Seven: Portable luminaires for garden use |
IEC 60598-2-4:2017 | Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires |
IEC 60216-3:2006 | Electrical insulating materials - Thermal endurance properties - Part 3: Instructions for calculating thermal endurance characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.