CSA E60598.1 : 2016
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
Hardcopy , PDF
07-17-2021
English
01-01-2016
FOREWORD
SECTION 0: GENERAL INTRODUCTION
SECTION 1: TERMS AND DEFINITIONS
SECTION 2: CLASSIFICATION OF LUMINAIRES
SECTION 3: MARKING
SECTION 4: CONSTRUCTION
SECTION 5: EXTERNAL AND INTERNAL WIRING
SECTION 6: Not used
SECTION 7: PROVISION FOR EARTHING
SECTION 8: PROTECTION AGAINST ELECTRIC SHOCK
SECTION 9: RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE
SECTION 10: INSULATION RESISTANCE AND ELECTRIC STRENGTH,
TOUCH CURRENT AND PROTECTIVE CONDUCTOR CURRENT
SECTION 11: CREEPAGE DISTANCES AND CLEARANCES
SECTION 12: ENDURANCE TEST AND THERMAL TEST
SECTION 13: RESISTANCE TO HEAT, FIRE AND TRACKING
SECTION 14: SCREW TERMINALS
SECTION 15: SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS
Annex A (normative) - Test to establish whether a conductive
part may cause an electric shock
Annex B (normative) - Test lamps
Annex C (normative) - Abnormal circuit conditions
Annex D (normative) - Draught-proof enclosure
Annex E (normative) - Determination of winding temperature
rises by the increase-inresistance method
Annex F (normative) - Test for resistance to stress corrosion
of copper and copper alloys
Annex G (normative) - Measurement of touch current and
protective conductor current
Annex H (Void)
Annex I (Void)
Annex J (informative) - Explanation of IP numbers for degrees
of protection
Annex K (informative) - Temperature measurement
Annex L (informative) - Guide to good practice in luminaire
design
Annex M (normative) - Determination of creepage distances
and clearances
Annex N (informative) - Explanation of marking for luminaires
that are not suitable for mounting on normally flammable
surfaces and covering with insulation materials
Annex O (Void)
Annex P (normative) - Absorption requirements for the
protective shield to be fitted to luminaires designed
for metal halide lamps which emit a high level of UV
radiation
Annex Q (informative) - Conformity testing during manufacture
Annex R (normative) - Schedule of amended subclauses
containing more serious/critical requirements which
require products to be retested
Annex S (normative) - Requirements for the identification of
a family or range of luminaires for type testing
Annex T (informative) - Reference to Class 0
Annex U (informative) - Creepage and clearances distances
for luminaires where a higher degree of availability
(impulse withstand category III) may be requested
Annex V (normative) - Additional test requirements for
terminal blocks with integrated screwless earthing
contact for direct connection to the luminaire housing
or to parts of the body
Annex W (normative) - Alternative thermal test for
thermoplastic luminaires
Annex X (normative)
Annex XA (normative) - Additional marking requirements
Bibliography
This Part 1 of IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V.
DevelopmentNote |
Supersedes CSA E598.1 (10/2004)
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0337-1
|
Pages |
480
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60811-3-1:1985 | Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking |
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV | Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC TR 62778:2014 | Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60682:1980 | Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 60634:1993 | Heat test source (H.T.S.) lamps for carrying out heating tests on luminaires |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
CSA C22.2 No. 0.4 : 2004(R2013) | BONDING OF ELECTRICAL EQUIPMENT |
IEC TR 60083:2015 | Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC |
IEC TR 62471-2:2009 | Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60570:2003+AMD1:2017 CSV | Electrical supply track systems for luminaires |
IEC 60929:2011+AMD1:2015 CSV | AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements |
IEC 60598-2-5:2015 | Luminaires - Part 2-5: Particular requirements - Floodlights |
IEC 60400:2017 | Lampholders for tubular fluorescent lamps and starterholders |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60598-2-6:1994 | Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps |
C22.2 NO. 43-17 | Lampholders (Binational standard with UL 496) |
ISO 75-2:2013 | Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV | Single-capped fluorescent lamps - Safety specifications |
IEC 61167:2015 | Metal halide lamps - Performance specification |
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV | DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements |
IEC 61346-1:1996 | Industrial systems, installations and equipment and industrial products - Structuring principles and reference designations - Part 1: Basic rules |
IEC 60364-7-702:2010 | Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Swimming pools and fountains |
IEC 60921:2004+AMD1:2006 CSV | Ballasts for tubular fluorescent lamps - Performance requirements |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60598-2-3:2002+AMD1:2011 CSV | Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting |
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV | Single-capped fluorescent lamps - Performance specifications |
IEC 60364-7-701:2006 | Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower |
IEC 62035:2014+AMD1:2016 CSV | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
CSA C22.2 No. 0.15 : 2015 | ADHESIVE LABELS |
IEC 60989:1991 | Separating transformers, autotransformers, variable transformersand reactors. |
IEC 61643-11:2011 | Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods |
IEC 80416-1:2008 | Basic principles for graphical symbols for use on equipment - Part 1: Creation of graphical symbols for registration |
IEC 62471:2006 | Photobiological safety of lamps and lamp systems |
IEC 61535:2009+AMD1:2012 CSV | Installation couplers intended for permanent connection in fixedinstallations |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 61558-2-5:2010 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-5: Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC TR 60972:1989 | Classification and interpretation of new lighting products |
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV | Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes |
ISO 4046-4:2002 | Paper, board, pulps and related terms — Vocabulary — Part 4: Paper and board grades and converted products |
AS 3771-1998 | Road lighting luminaires with integral control gear |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60923:2005+AMD1:2006 CSV | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements |
IEC 60432-3:2012 | Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle) |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
CSA C22.2 No. 62031 : 2013(R2018) | LED MODULES FOR GENERAL LIGHTING - SAFETY SPECIFICATIONS |
IEC 60598-2-4:2017 | Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires |
IEC 61184:2017 | Bayonet lampholders |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
ISO 16893-1:2008 | Wood-based panels — Particleboard — Part 1: Classifications |
IEC 60360:1998 | Standard method of measurement of lamp cap temperature rise |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
ISO 1891:2009 | Fasteners — Terminology |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.