CSA CISPR 16-1-2 : 2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-2: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - COUPLING DEVICES FOR CONDUCTED DISTURBANCE MEASUREMENTS
Hardcopy , PDF
11-28-2019
English
01-01-2015
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Artificial mains networks
5 Current and voltage probes
6 Coupling units for conducted current immunity measurement
7 Coupling devices for measuring signal lines
8 The artificial hand and series RC element
9 CDNE for measurement of disturbance voltage in frequency
range 30 MHz to 300 MHz
Annex A (normative) - AMNs
Annex B (informative) - Construction, frequency range, and
calibration of current probes
Annex C (informative) - Construction of the coupling units for
current injection for the frequency range 0,15 MHz
to 30 MHz
Annex D (informative) - Principle of operation and examples
of coupling units for conducted current immunity
measurements
Annex E (normative) - Example and measurement of the
parameters of the asymmetric artificial network (AAN)
Annex F (normative) - Example and measurement of the
parameters of the AN for coaxial and other screened
cables
Annex G (informative) - Construction and evaluation of
capacitive voltage probe
Annex H (informative) - Rationale for the introduction of a
minimum decoupling factor between mains and
EUT/receiver ports for the V-AMN
Annex I (informative) - Rationale for the introduction of a
phase tolerance for the VAMN input impedance
Annex J (informative) - Example CDNE set-up diagrams
Bibliography
Describes the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz.
DocumentType |
Standard
|
Pages |
211
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
CAN/CSA-CISPR 32:17 | Electromagnetic compatibility of multimedia equipment — Emission requirements (Adopted IEC CISPR 32:2015, second edition, 2015-03, with Canadian deviations) | Compatibilité électromagnétique des équipements multimédia — Exigences d’émission (norme IEC CISPR 32:2015 adoptée, deuxième édition, 2015-03, avec exigences propres au Canada) |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 16-2-1:2014 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
CISPR TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.