• Shopping Cart
    There are no items in your cart

CLSI EP18 P3 : 3ED 2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

RISK MANAGEMENT TECHNIQUES TO IDENTIFY AND CONTROL LABORATORY ERROR SOURCES

Superseded date

11-30-2009

Superseded by

CLSI EP18 A2 : 2ED 2009

Published date

01-12-2013

Sorry this product is not available in your region.

Abstract
Committee Membership
Foreword
Laboratory Error Sources and CLSI Evaluation Protocols
Documents
1 Scope
2 Introduction
3 Standard Precautions
4 Terminology
  4.1 A Note on Terminology
  4.2 Definitions
  4.3 Acronyms/Abbreviations
5 User-Manufacturer Quality Partnership
  5.1 Manufacturer's Responsibility
  5.2 User's Responsibility
6 FMEA, FTA and FRACAS
  6.1 Description of FMEA, FTA and FRACAS
  6.2 Definition and Purpose
  6.3 Some General Guidelines for FMEA, FTA and FRACAS
  6.4 Description of FMEA Table Entries
  6.5 Fault Trees
  6.6 Control Measures (FMEA) or Corrective Action (FRACAS)
  6.7 Validation (FMEA)
  6.8 Rate Measure (FRACAS)
  6.9 Other Considerations
  6.10 Pareto Analysis
  6.11 More on FRACAS for Clinical Laboratories
  6.12 Other Aids to Facilitate FMEA and FRACAS
References
Appendix A - Example of a "System-Specific Sources of Error"
             Matrix - an FMEA
Appendix B - An Example of a Manufacturer's FMEA
Appendix C - Laboratory FMEA: Manufacturer completed part
             and Clinical Laboratory completed part
Appendix D - Example of a FRACAS
Appendix E - A Note on Unit-Use Devices
Summary of Consensus Comments and Committee Responses
The Quality Management System Approach
Related CLSI Publications

Specifies risk management techniques that will aid in identifying, understanding, and managing sources of failure (potential failure modes) and help to ensure correct results.

DevelopmentNote
Supersedes NCCLS EP18 P2. (03/2009)
DocumentType
Proposed Guideline
PublisherName
Clinical Laboratory Standards Institute
Status
Superseded
SupersededBy
Supersedes

CLSI I/LA33 P : 1ED 2009 VALIDATION OF AUTOMATED DEVICES FOR IMMUNOHEMATOLOGIC TESTING PRIOR TO IMPLEMENTATION

CLSI EP14 A2 : 2ED 2005 EVALUATION OF MATRIX EFFECTS
CLSI EP21 A : 1ED 2003 ESTIMATION OF TOTAL ANALYTICAL ERROR FOR CLINICAL LABORATORY METHODS
CLSI EP5 A2 : 2ED 2004 EVALUATION OF PRECISION PERFORMANCE OF QUANTITATIVE MEASUREMENT METHODS
CLSI EP12 A2 : 2ED 2008 USER PROTOCOL FOR EVALUATION OF QUALITATIVE TEST PERFORMANCE
CLSI GP10 A : 1ED 95(R2001) ASSESSMENT OF THE CLINICAL ACCURACY OF LABORATORY TESTS USING RECEIVER OPERATING CHARACTERISTIC (ROC) PLOTS
CLSI EP6 A : 1ED 2003 EVALUATION OF THE LINEARITY OF QUANTITATIVE MEASUREMENT PROCEDURES - A STATISTICAL APPROACH
CLSI EP15 A2 : 2ED 2006 USER VERIFICATION OF PERFORMANCE FOR PRECISION AND TRUENESS
CLSI EP19 R : 1ED 2002 A FRAMEWORK FOR NCCLS EVALUATION PROTOCOLS
CLSI GP26 A3 : 3ED 2004 APPLICATION OF A QUALITY MANAGEMENT SYSTEM MODEL FOR LABORATORY SERVICES
CLSI EP7 A2 : 2ED 2005 INTERFERENCE TESTING IN CLINICAL CHEMISTRY
CLSI EP9 A2 : 2ED 2002 METHOD COMPARISON AND BIAS ESTIMATION USING PATIENT SAMPLES
CLSI EP10 A3 : 2006 + A1 2014 PRELIMINARY EVALUATION OF QUANTITATIVE CLINICAL LABORATORY MEASUREMENT PROCEDURES