CLC/TS 50217:2005
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Guide for in situ measurements - In situ measurement of disturbance emission
03-10-2023
08-11-2005
1 Scope
2 Normative references
3 Definitions - Terms and abbreviations
4 Overview of the methodology
4.1 Measurement techniques
4.2 Methodology in case of complaint
5 Selection of measurement location and general condition
5.1 General
5.2 Frequency range up to 30 MHz
5.3 Frequency range above 30 MHz
5.4 Emission measurements in the presence of ambient signal
6 Measurement of conducted emissions
6.1 Disturbance below 9 kHz
6.2 Disturbance in the frequency range 9 kHz to 30 MHz
7 Measurement of radiated emissions
7.1 General
7.2 Frequency range above 9 kHz
7.3 Field strength specific indoors measurement
7.4 Radiated disturbance power in the frequency range above 30 MHz
8 Measurement report
Annex A (informative) Investigation in case of complaint
A.1 Identification of the interference
A.2 Evaluation of the victim and characterisation of the
source of interference
A.3 Evaluation of results
Annex B (informative) Protection of radio communications services
B.1 Radio services
B.2 Safety services
Annex C (informative) Measurement techniques
C.1 Rationale for excluding compliance testing
C.2 Measurement distance below 3 m
C.3 Active dipole
Annex D (informative) Low frequency phenomena
D.1 Measurement techniques for low frequency (below 9 kHz)
D.2 Disturbance emission from mains, or other power circuits
D.3 Measurement of conducted emissions
D.4 Radiated emission in the frequency range up to 9 kHz
Bibliography
This guide describes analysis methods of disturbance emission to be applied in situ for identification of the disturbance source and resolution of complaint. Where applicable, the methods rely on already published documents either in CENELEC or in IEC. It is not intended to be used for type testing or any kind of conformity assessment. Dealing with effects on living matter is excluded from this document. The frequency range of interest is from d.c. to 400 GHz. This document applies for analysing an interference complaint. It provides method for identification and characterisation in situ of the source(s) of interference. It proposes procedures to discriminate different kind of sources. Reference in situ measurement distances are defined. It allows comparison of the results and of technical characteristics of the interfered equipment with existing relevant standards. The result of the comparison is intended to help in the resolution of the complaint. It is meant for verifying the emissions from fixed installations whatever equipment they contain, and whatever have been the type tests of these equipment. It may be used to describe the coupling path for interference between the victim and the source, and to compare the measurement results with the limits from the adequate standard, at a specific location and in a given frequency band.
Committee |
CLC/TC 210
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
DD CLC/TS 50217:2005 | Identical |
I.S. CLC/TS 50217:2005 | Identical |
NEN NPR CLC/TS 50217 : 2005 | Identical |
CEI CLC/TS 50217 : 2006 | Identical |
UNE-CLC/TS 50217:2006 | Identical |
CEI CWA 50487 : 2006 | SMARTHOUSE CODE OF PRACTICE |
PD CISPR/TR 16-2-5:2008 | Specification for radio disturbance and immunity measuring apparatus and methods In situ measurements of disturbing emissions produced by physically large equipment |
07/30170284 DC : DRAFT AUG 2007 | CISPR 16-2-5 - SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-5: IN SITU MEASUREMENTS FOR DISTURBING EMISSIONS PRODUCED BY PHYSICALLY LARGE EQUIPMENT |
CISPR TR 16-2-5:2008 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-5: In situ measurements for disturbing emissions produced by physically large equipment |
EN 300 386 : 1.6.1 | TELECOMMUNICATION NETWORK EQUIPMENT; ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF THE DIRECTIVE 2014/30/EU |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
IEC 61000-2-4:2002 | Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances |
IEC 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
EN 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
EN 61000-3-11:2000 | Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 61000-2-4:2002/AC:2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES |
EN 50083-8:2013 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 8: ELECTROMAGNETIC COMPATIBILITY FOR NETWORKS |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
EN 61000-4-7:2002/A1:2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008) |
IEC TR 61000-5-2:1997 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
IEC 61000-4-15:2010 | Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications |
IEC 61786:1998 | Measurement of low-frequency magnetic and electric fields with regard to exposure of human beings - Special requirements for instruments and guidance for measurements |
IEC TS 61000-3-4:1998 | Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011) |
IEC 61000-4-7:2002+AMD1:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto |
EN 61800-3 : 2004 AMD 1 2012 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC TR 61000-2-8:2002 | Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results |
EN 61000-4-15:2011 | Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications |
IEC TR 61000-5-1:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-