CLC/TS 50131-3:2003
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Alarm systems - Intrusion systems - Part 3: Control and indicating equipment
03-09-2023
07-31-2003
1 Scope
2 Normative references
3 Definitions and abbreviations
3.1 Definitions
3.2 Abbreviations
4 Equipment attributes
4.1 General
4.2 Functionality
5 CIE structure
6 Security grade
7 Environmental requirements
7.1 General
7.2 Environmental class I: Indoor
7.3 Environmental class II: Indoor - General
7.4 Environmental class III: Outdoor - Sheltered
7.5 Environmental class IV: Outdoor - General
7.6 Special condition
7.7 Environmental tests
8 Functional requirements
8.1 Inputs
8.2 Operation
8.3 Processing
8.4 Indication
8.5 Notification outputs
8.6 Tamper security (detection/protection)
8.7 Fault
8.8 Interconnections
8.9 Timing
8.10 Event recording
8.11 Power supply
9 Electrical safety
10 Product documentation
10.1 Installation and maintenance
10.2 Operating instructions
11 Marking and labelling
12 Tests
12.1 Test conditions
12.2 Functional tests
12.3 Reduced functional test
12.4 Functional tests
12.5 Access level
12.6 Authorization requirements
13 Environmental tests
13.1 General
13.2 Environmental test selection
Annexes
Annex A (informative) Interconnection types
Annex B (informative) Example of calculation for code
variations
Annex C (informative) Summary of timing requirements
Covers the requirements, testing procedures security and environmental performance criteria for control and indicating equipment (CIE) intended for use in intrusion alarm system (IAS) and hold-up alarm systems (HAS) installed in buildings.
Committee |
CLC/TC 79
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
XP CLC/TS 50131-3 : 2005 XP | Identical |
DD CLC/TS 50131-3:2003 | Identical |
UNE-CLC/TS 50131-3:2005 EX | Identical |
CEI CLC/TS 50131-3 : 2004 | Identical |
SN CLC/TS 50131-3 : 2003 | Identical |
VDE V 0830-2-3 : 2005 | Identical |
UNE-CLC/TS 50131-3:2005 V2 | Identical |
NEN NPR CLC/TS 50131-3 : 2003 | Identical |
I.S. CLC TS 50131-3:2003 | Identical |
DIN CLC/TS 50131-3 : 2005 | Identical |
PD CLC/TR 50531:2009 | Alarm systems. Terms and definitions |
S.R. CLC/TR 50531:2009 | ALARM SYSTEMS - TERMS AND DEFINITIONS |
CLC/TR 50531:2009 | Alarm systems - Terms and definitions |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.