CISPR 22:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-31-2021
English - French, Spanish, Castilian
09-24-2008
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Definitions
4 Classification of ITE
4.1 Class B ITE
4.2 Class A ITE
5 Limits for conducted disturbance at mains terminals and
telecommunication ports
5.1 Limits of mains terminal disturbance voltage
5.2 Limits of conducted common mode (asymmetric mode)
disturbance at telecommunication ports
6 Limits for radiated disturbance
6.1 Limits below 1 GHz
6.2 Limits above 1 GHz
7 Interpretation of CISPR radio disturbance limit
7.1 Significance of a CISPR limit
7.2 Application of limits in tests for conformity of
equipment in series production
8 General measurement conditions
8.1 Ambient noise
8.2 General arrangement
8.3 EUT arrangement
8.4 Operation of the EUT
9 Method of measurement of conducted disturbance at
mains terminals and telecommunication ports
9.1 Measurement detectors
9.2 Measuring receivers
9.3 Artificial mains network (AMN)
9.4 Ground reference plane
9.5 EUT arrangement
9.6 Measurement of disturbances at telecommunication
ports
9.7 Recording of measurements
10 Method of measurement of radiated disturbance
10.1 Measurement detectors
10.2 Measuring receiver below 1 GHz
10.3 Antenna below 1 GHz
10.4 Measurement site below 1 GHz
10.5 EUT arrangement below 1 GHz
10.6 Radiated emission measurements above 1 GHz
10.7 Recording of measurements
10.8 Measurement in the presence of high ambient signals
10.9 User installation testing
11 Measurement uncertainty
Annex A (normative) Site attenuation measurements of
alternative test sites
Annex B (normative) Decision tree for peak detector
measurements
Annex C (normative) Possible test set-ups for common mode
measurements
Annex D (informative) Schematic diagrams of examples of
impedance stabilization networks (ISN)
Annex E (informative) Parameters of signals at
telecommunication ports
Annex F (informative) Rationale for disturbance
measurements and methods on telecommunications
ports
Annex G (informative) Operational modes for some types of
ITE
Bibliography
CISPR 22:2008 is available as CISPR 22:2008 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
CISPR 22:2008 applies to information technology equipment (ITE). Procedures are given for the measurement of the levels of spurious signals generated by the ITE and limits are specified for the frequency range 9 kHz to 400 GHz for both class A and class B equipment. No measurements need be performed at frequencies where no limits are specified. The intention of this publication is to establish uniform requirements for the radio disturbance level of the equipment contained in the scope, to fix limits of disturbance, to describe methods of measurement and to standardize operating conditions and interpretation of results. This sixth edition of CISPR 22 cancels and replaces the fifth edition published in 2005, its Amendment 1 (2005) and Amendment 2 (2006). This edition constitutes a minor revision.
DocumentType |
Standard
|
Pages |
169
|
ProductNote |
NEW CHILD ISH 3 IS ADDED NOW
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
AS/NZS CISPR 22:2009 | Identical |
NBN EN 55022 : 2011 | Identical |
BS EN 55022:2010 | Identical |
DIN EN 55022 : 2011 COR 1 2016 | Identical |
VDE 0878-22 : 2011 COR 1 2016 | Identical |
BIS IS 6873-7 : 2012 | Identical |
NF EN 55022 : 2012 | Identical |
IEEE C63.022-1996 | Identical |
UNE-EN 55022:2011 | Identical |
BS 6527:1988 | Similar to |
VDE 0878-3 : 1989 | Similar to |
I.S. EN 62343-2:2014 | DYNAMIC MODULES - PART 2: RELIABILITY QUALIFICATION |
ISO/IEC 8802-12:1998 | Information technology — Telecommuncations and information exchange between systems — Local and metropolitan area networks — Specific requirements — Part 12: Demand-Priority access method, physical layer and repeater specifications |
CLC/TS 50217:2005 | Guide for in situ measurements - In situ measurement of disturbance emission |
NF EN 61672-2 : 2014 AMD 1 2017 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
DIN EN ISO 8041-1:2017-10 | HUMAN RESPONSE TO VIBRATION - MEASURING INSTRUMENTATION - PART 1: GENERAL PURPOSE VIBRATION METERS (ISO 8041-1:2017) |
BS EN 50498:2010 | Electromagnetic compatibility (EMC). Product family standard for aftermarket electronic equipment in vehicles |
DD IEC TS 62370 : 2004 | ELECTROACOUSTICS - INSTRUMENTS FOR THE MEASUREMENT OF SOUND INTENSITY - ELECTROMAGNETIC AND ELECTROSTATIC COMPATIBILITY REQUIREMENTS AND - TEST PROCEDURES |
BS EN 50065-2-3:2003 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 Khz Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors |
CSA ISO/IEC 8802-5 : 2002 : INC : UPD 1 : 2002 : R2011 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
11/30253123 DC : 0 | BS EN 12016 - ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - IMMUNITY |
BS ISO 14302:2002 | Aerospace series. Space systems. Electromagnetic compatibility requirements |
NF EN 61000-6-2 : 2006 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS |
NF EN 1434-4 : 2016 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
CLC/TR 50484:2009 | Recommendations for shielded enclosures |
12/30265786 DC : 0 | BS EN 14908-2 - OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 2: TWISTED PAIR COMMUNICATION |
CEI EN 60942 : 2004 | ELECTROACOUSTICS SOUND CALIBRATORS |
05/30135559 DC : 0 | EN 50471 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PRODUCT FAMILY EMISSION STANDARD FOR WIRE-LINE TELECOMMUNICATION NETWORKS |
I.S. EN 50065-2-2:2003 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-2: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN INDUSTRIAL ENVIRONMENTS |
05/30134522 DC : DRAFT JUN 2005 | ISO 23273-1 - FUEL CELL ROAD VEHICLES - SAFETY SPECIFICATIONS - PART 1: VEHICLE FUNCTIONAL SAFETY |
BS EN 61252 : 1997 | ELECTROACOUSTICS - SPECIFICATIONS FOR PERSONAL SOUND EXPOSURE METERS |
BS EN 50082-1:1998 | Electromagnetic compatibility. Generic immunity standard Residential, commercial and light industry |
BS EN 50561-1:2013 | Power line communication apparatus used in low-voltage installations. Radio disturbance characteristics. Limits and methods of measurement Apparatus for in-home use |
S.R. CLC/TR 50485:2010 | ELECTROMAGNETIC COMPATIBILITY - EMISSION MEASUREMENTS IN FULLY ANECHOIC CHAMBERS |
BS EN 61036:1997 | Alternating current static watt-hour meters for active energy (classes 1 and 2) |
BS ISO 21750:2006 | Road vehicles. Safety enhancement in conjunction with tyre inflation pressure monitoring |
CEI EN 62586-1 : 2016 | POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI) |
BS PD CISPR/TR 16-4-4 : 2007 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 4-4: UNCERTAINTIES, STATISTICS AND LIMIT MODELLING - STATISTICS OF COMPLAINTS AND A MODEL FOR THE CALCULATION OF LIMITS FOR THE PROTECTION OF RADIO SERVICES |
07/30173734 DC : 0 | BS EN 55024 - INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
INCITS/ISO/IEC 24700 : 2008 | QUALITY AND PERFORMANCE OF OFFICE EQUIPMENT THAT CONTAINS REUSED COMPONENTS |
PD CISPR/TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods Uncertainties, statistics and limit modelling. Uncertainties in standardized EMC tests |
09/30201391 DC : 0 | BS EN 55016-4-2 ED.2 - SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 4-2: UNCERTAINTIES, STATISTICS AND LIMIT MODELLING - MEASUREMENT INSTRUMENTATION UNCERTAINTY |
NF EN 55103-1 : 2009 AMD 1 2013 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS |
I.S. EN 61800-3:2005 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004 (EQV)) |
INCITS/ISO/IEC 11159 : 1996 | INFORMATION TECHNOLOGY - OFFICE EQUIPMENT - MINIMUM INFORMATION TO BE INCLUDED IN SPECIFICATION SHEETS - COPYING MACHINES |
13/30252774 DC : 0 | BS EN 50121-3-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 3-2: ROLLING STOCK - APPARATUS |
BS EN 60255-26:2013 | Measuring relays and protection equipment Electromagnetic compatibility requirements |
DD CEN ISO/TS 14907-1:2010 | Electronic fee collection. Test procedures for user and fixed equipment Description of test procedures |
BS EN 62333-2 : 2006 | NOISE SUPPRESSION SHEET FOR DIGITAL DEVICES AND EQUIPMENT - PART 2: MEASURING METHODS |
15/30326444 DC : 0 | BS EN 60942 - ELECTROACOUSTICS - SOUND CALIBRATORS |
BS EN 50293:2012 | Road traffic signal systems. Electromagnetic compatibility |
BS EN 61260-1:2014 | Electroacoustics. Octave-band and fractional-octave-band filters Specifications |
99/240940 DC : 0 | BS EN 50331-1 - PHOTOVOLTAIC SYSTEMS IN BUILDINGS - PART 1: SAFETY REQUIREMENTS |
BS ISO/IEC 8802-3:1996 | Information technology. Telecommunications and information exchange between systems. Local and metropolitan area networks. Specific requirements Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
BS EN 50065-2-2:2003 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments |
BS EN 61000-6-3 : 2007 : INC : AMD 1 : 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
08/30195483 DC : 0 | BS EN 61812-1 - TIME RELAYS FOR INDUSTRIAL AND RESIDENTIAL USE - PART 1: REQUIREMENTS AND TESTS |
CEI EN 50498 : 2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PRODUCT FAMILY STANDARD FOR AFTERMARKET ELECTRONIC EQUIPMENT IN VEHICLES |
CAN/CSA-ISO/IEC 8802-5-02 (R2011) | Information Technology - Telecommunications and Information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements - Part 5: Token Ring Access Method and Physical Layer Specifications (Adopted ISO/IEC 8802-5:1998 / ANSI/IEEE 802.5:1998, third edition, 1998-09-15) |
SAE J 2578 : 2014 | RECOMMENDED PRACTICE FOR GENERAL FUEL CELL VEHICLE SAFETY |
CSA C61000-6-1 : 2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
CLC/TR 50485:2010 | Electromagnetic compatibility - Emission measurements in fully anechoic chambers |
EN 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
I.S. EN 55016-2-3:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-3: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - RADIATED DISTURBANCE MEASUREMENTS |
I.S. EN 50121-2:2017 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
CSA ISO/IEC 15018 : 2005 : R2010 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
EN ISO 15254:2009 | Ophthalmic optics and instruments - Electro-optical devices for enhancing low vision (ISO 15254:2009) |
CSA ISO/IEC 15018:2005 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
BS EN 61000-6-3 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R201000 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
I.S. ETS 300 157:1993 | SATELLITE EARTH STATIONS (SES) - RECEIVE-ONLY VERY SMALL APERTURE TERMINALS (VSATS) USED FOR DATA DISTRIBUTION OPERATING IN THE 11/12 GHZ FREQUENCY BANDS |
CEI EN 61000-4-21 : 2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-21: TESTING AND MEASUREMENT TECHNIQUES - REVERBERATION CHAMBER TEST METHODS |
I.S. EN 55103-1:2009 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS |
S.R. HD 60364-5-51:2009 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES |
CEI EN 50293 : 2013 | ROAD TRAFFIC SIGNAL SYSTEMS - ELECTROMAGNETIC COMPATIBILITY |
BS EN 61672-2 : 2013 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
IEEE DRAFT 802.5 : 1995 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - LAN/MAN-TYPE SPECIFIC REQUIREMENTS - TOKEN RING ACCESS METHOD AND PHYSICAL LATER SPECIFICATION |
EN 50561-1:2013/AC:2015 | Power line communication apparatus used in low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement - Part 1: Apparatus for in-home use |
I.S. EN IEC 60942:2018 | ELECTROACOUSTICS - SOUND CALIBRATORS |
BS EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz General requirements, frequency bands and electromagnetic disturbances |
BS EN 60947-2:2017 | Low-voltage switchgear and controlgear Circuit-breakers |
I.S. EN 50561-1:2013 | POWER LINE COMMUNICATION APPARATUS USED IN LOW-VOLTAGE INSTALLATIONS - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - PART 1: APPARATUS FOR IN-HOME USE |
CEI EN 61672-2 : 2014 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
UNE-EN 50121-3-2:2017 | Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
NF EN 60934 : 2001 AMD 2 2013 | CIRCUIT-BREAKERS FOR EQUIPMENT (CBE) |
OVE/ONORM EN 62040-2 : 2006 | |
NF EN 60947-8 : 2003 AMD 2 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 8: CONTROL UNITS FOR BUILT-IN THERMAL PROTECTION (PTC) FOR ROTATING ELECTRICAL MACHINES |
TS 134 124 : 13.0.0 | UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM (UMTS); ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS FOR MOBILE TERMINALS AND ANCILLARY EQUIPMENT (3GPP TS 34.124 VERSION 14.0.0 RELEASE 14) |
I.S. EN 50370-1:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PRODUCT FAMILY STANDARD FOR MACHINE TOOLS - PART 1: EMISSION |
BS EN 61812-1:2011 | Time relays for industrial and residential use Requirements and tests |
BS EN 55024 : 2010 | INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
CSA CISPR 16-1-2 : 2015 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-2: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - COUPLING DEVICES FOR CONDUCTED DISTURBANCE MEASUREMENTS |
I.S. EN 62488-2:2017 | POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 2: ANALOGUE POWER LINE CARRIER TERMINALS OR APLC |
NF EN 61260-1 : 2014 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 1: SPECIFICATIONS |
NF EN 62310-2 : 2007 | STATIC TRANSFER SYSTEMS (STS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
CSA C22.2 No. 61980-1 : 2016 | ELECTRIC VEHICLE WIRELESS POWER TRANSFER (WPT) SYSTEMS - PART 1: GENERAL REQUIREMENTS |
GOST R IEC 61850-3 : 2005 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 3 - GENERAL REQUIREMENTS |
S.R. CLC/TR 50083-10-1:2014 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 10-1: GUIDELINES FOR THE IMPLEMENTATION OF RETURN PATHS IN CABLE NETWORKS |
ANSI/ASA S1.4 PART 2 : 2014 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
ISO/IEC 15404:2000 | Information technology — Office machines — Minimum information to be included in specification sheets — Facsimile equipment |
BS EN ISO 8041:2005 | Human response to vibration. Measuring instrumentation |
09/30162904 DC : 0 | BS EN 61204-3 - LOW-VOLTAGE POWER SUPPLIES, D.C. OUTPUT - PART 3: ELECTROMAGNETIC COMPATIBILITY (EMC) |
BS EN 12414:1999 | Vehicle parking control equipment. Pay and display ticket machine. Technical and functional requirements |
17/30355856 DC : 0 | BS EN 60947-2 AMENDMENT 1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS |
BS EN 61851-21:2002 | Electric vehicle conductive charging system Electric vehicle requirements for conductive connection to an a.c./d.c. supply |
UNE-EN 61812-1:2012 | Time relays for industrial and residential use - Part 1: Requirements and tests |
BS EN 12015:2014 | Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks. Emission |
UNE-EN 62870:2016 | Electrical installations for lighting and beaconing of aerodromes - Safety secondary circuits in series circuits - General safety requirements |
UNE-EN 50083-2:2013 | Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment |
IEC 61037:1990+AMD1:1996+AMD2:1998 CSV | Electricity metering - Tariff and load control - Particular requirements for electronic ripple control receivers |
EN 50083-8:2013 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 8: ELECTROMAGNETIC COMPATIBILITY FOR NETWORKS |
CLC/TR 50538:2010 | Guide to EMC Directive conformity of equipment designed for military purposes |
EN 60651:1994/A2:2001 | SOUND LEVEL METERS (IEC 60651:1979/A2:2000) |
EN 61000-4-20:2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES |
EN 60835-3-13:1996 | Methods of measurement for equipment used in digital microwave radio transmission systems - Part 3: Measurements on satellite earth stations - Section 13: VSAT systems |
EN 61260-1:2014 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications |
HD 60364-5-51:2009/A12:2017 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES |
DIN EN ISO 8041:2006-06 | HUMAN RESPONSE TO VIBRATION - MEASURING INSTRUMENTATION |
IEC 61204-3:2016 RLV | Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
EN 50293:2012 | Road traffic signal systems - Electromagnetic compatibility |
DIN EN ISO 15254:2009-10 | Ophthalmic optics and instruments - Electro-optical devices for enhancing low vision (ISO 15254:2009) |
EN 60947-8:2003/A2:2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 8: CONTROL UNITS FOR BUILT-IN THERMAL PROTECTION (PTC) FOR ROTATING ELECTRICAL MACHINES (IEC 60947-8:2003/A2:2011) |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
DIN EN 12015:1998-08 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - EMISSION |
EN 62310-2:2007 | Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
UNI EN ISO 15254 : 2009 | OPHTHALMIC OPTICS AND INSTRUMENTS - ELECTRO-OPTICAL DEVICES FOR ENHANCING LOW VISION |
EN 55020:2007/A12:2016 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006) |
EN 61822:2009 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - CONSTANT CURRENT REGULATORS |
EN 50083-2:2012/A1:2015 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT |
EN 61069-7:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 7: Assessment of system safety |
EN 50428 : 2005 AMD 2 2009 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - COLLATERAL STANDARD - SWITCHES AND RELATED ACCESSORIES FOR USE IN HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) |
EN 50082-1:1997 | Electromagnetic compatibility - Generic immunity standard - Part 1: Residential, commercial and light industry |
EN 61850-3:2014 | Communication networks and systems for power utility automation - Part 3: General requirements |
EN 50082-2 : 95 AC 95 | ELECTROMAGNETIC COMPATIBILITY - GENERIC IMMUNITY STANDARD - INDUSTRIAL ENVIRONMENT |
EN 55013:2013/A1:2016 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 13:2009, MODIFIED) |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEEE/ANSI C63.4-2014 | American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz |
EN 60255-25:2000 | Electrical relays - Part 25: Electromagnetic emission tests for measuring relays and protection equipment |
NF EN ISO 8041-1 : 2017 | HUMAN RESPONSE TO VIBRATION - MEASURING INSTRUMENTATION - PART 1: GENERAL PURPOSE VIBRATION METERS |
CEI EN 50121-3-2 : 2016 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 3-2: ROLLING STOCK - APPARATUS |
11/30255400 DC : 0 | BS EN 50293 - ELECTROMAGNETIC COMPATIBILITY - ROAD TRAFFIC SIGNAL SYSTEMS |
14/30279327 DC : 0 | BS EN 61800-3 AMD2 - ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS |
BS EN 55032:2015 | Electromagnetic compatibility of multimedia equipment. Emission Requirements |
BS EN 61000-6-2:2005 | Electromagnetic compatibility (EMC) Generic standards - Immunity for industrial environments |
BS IEC 62003:2009 | Nuclear power plants. Instrumentation and control important to safety. Requirements for electromagnetic compatibility testing |
16/30340728 DC : 0 | BS EN 50121-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
NF EN 60761-2 : 2005 | EQUIPMENT FOR CONTINUOUS MONITORING RADIOACTIVITY IN GASEOUS EFFLUENTS - PART 2: SPECIFIC REQUIREMENTS FOR AEROSOLS MONITORS INCLUDING TRANSURANIC AEROSOLS |
CSA CISPR 16-1-1 : 2015 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS |
EN 61851-21-1:2017/AC:2017-11 | ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM - PART 21-1: ELECTRIC VEHICLE ON-BOARD CHARGER EMC REQUIREMENTS FOR CONDUCTIVE CONNECTION TO AN AC/DC SUPPLY (IEC 61851-21-1:2017) |
BS EN 60942:2003 | Electroacoustics. Sound calibrators |
15/30271483 DC : 0 | BS EN 61851-21-1 ED 1.0 - ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM PART 21-1 ELECTRIC VEHICLE ONBOARD CHARGER EMC REQUIREMENTS FOR CONDUCTIVE CONNECTION TO A.C./D.C. SUPPLY |
I.S. EN 61000-6-1:2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
17/30336998 DC : 0 | BS IEC 62969-4 ED.1.0 - SEMICONDUCTOR DEVICES - SEMICONDUCTOR INTERFACES FOR AUTOMOTIVE VEHICLES - PART 4: EVALUATION METHOD OF DATA INTERFACE FOR AUTOMOTIVE VEHICLE SENSORS |
INCITS/ISO/IEC 11159 : 1996 : R2004 | INFORMATION TECHNOLOGY - OFFICE EQUIPMENT - MINIMUM INFORMATION TO BE INCLUDED IN SPECIFICATION SHEETS - COPYING MACHINES |
16/30340734 DC : 0 | BS EN 50121-3-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 3-2: ROLLING STOCK - APPARATUS |
13/30261307 DC : 0 | BS ISO 11452-1 - ROAD VEHICLES - COMPONENT TEST METHODS FOR ELECTRICAL DISTURBANCES FROM NARROWBAND RADIATED ELECTROMAGNETIC ENERGY - PART 1: GENERAL PRINCIPLES AND TERMINOLOGY |
DD CLC/TS 50217:2005 | Guide for in situ measurements. In situ measurement of disturbance emission |
08/30177580 DC : DRAFT FEB 2008 | BS EN 61260-1 - ELECTRO ACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 1: SPECIFICATIONS |
BIS IS 6873-5 : 2012 | LIMITS AND METHODS OF MEASUREMENT OF RADIO DISTURBANCE CHARACTERISTICS - PART 5: ELECTRICAL LIGHTING AND SIMILAR EQUIPMENTS |
BS PD IEC TS 62370 : 2004 | ELECTROACOUSTICS - INSTRUMENTS FOR THE MEASUREMENT OF SOUND INTENSITY - ELECTROMAGNETIC AND ELECTROSTATIC COMPATIBILITY REQUIREMENTS AND TEST PROCEDURES |
UNE-EN 50293:2013 | Road traffic signal systems - Electromagnetic compatibility |
NF EN 50090-9-1 : 2004 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 9-1: INSTALLATION REQUIREMENTS - GENERIC CABLING FOR HBES CLASS 1 TWISTED PAIR |
ETR 077 : 20001 | |
NF EN 61204-3 : 2001 | LOW VOLTAGE POWER SUPPLIES, D.C. OUTPUT - PART 3: ELECTROMAGNETIC COMPATIBILITY (EMC) |
NF EN 55024 : 2011 AMD 1 2015 | INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
BS EN 61000-4-20:2003 | Electromagnetic Compatibility (EMC) Testing and measurement techniques. Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
NF EN 60761-5 : 2005 | EQUIPMENT FOR CONTINUOUS MONITORING RADIOACTIVITY IN GASEOUS EFFLUENTS - PART 5: SPECIFIC REQUIREMENTS FOR TRITIUM MONITORS |
BS EN 50370-1:2005 | Electromagnetic compatibility (EMC). Product family standard for machine tools Emission |
I.S. EN 60835-3-13:1999 | METHODS OF MEASUREMENT FOR EQUIPMENT USED IN DIGITAL MICROWAVE RADIO TRANSMISSION SYSTEMS - PART 3: MEASUREMENTS ON SATELLITE EARTH STATIONS - SECTION 13: VSAT SYSTEMS |
BS DD8431(2005) : 2005 | ELECTRICAL STATIC METERS FOR SECONDARY METERING AND SUB-METERING - SPECIFICATION |
BS EN 61260-2 : 2016 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS |
CEI EN 61851-22 : 2003 | ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM - PART 22: AC ELECTRIC VEHICLE CHARGING STATION |
CSA ISO/IEC 8802-3 : 2002 : R2016 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
CEI EN 62488-2 : 1ED 2018 | POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 2: ANALOGUE POWER LINE CARRIER TERMINALS OR APLC |
I.S. EN 60942:2003 | ELECTROACOUSTICS - SOUND CALIBRATORS |
16/30328917 DC : DRAFT APR 2016 | BS EN 62488-2 ED 1.0 - POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 2: ANALOGUE POWER LINE CARRIER TERMINALS (APLC) |
CEI EN 60834-1 : 2001 | TELEPROTECTION EQUIPMENT OF POWER SYSTEMS - PERFORMANCE AND TESTING - PART 1: COMMAND SYSTEMS |
CEI EN 50370-1 : 2006 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PRODUCT FAMILY STANDARD FOR MACHINE TOOLS - PART 1: EMISSION |
BS IEC 61000-3.8 : 1997 | ELECTROMAGNETIC COMPATIBILITY (EMC) - LIMITS - GUIDE TO SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS - EMISSION LEVELS, FREQUENCY BANDS AND ELECTROMAGNETIC DISTURBANCE LEVELS |
07/30170284 DC : DRAFT AUG 2007 | CISPR 16-2-5 - SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-5: IN SITU MEASUREMENTS FOR DISTURBING EMISSIONS PRODUCED BY PHYSICALLY LARGE EQUIPMENT |
CEI EN 61000-6-2 : 2006 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS |
CEI EN 62488-1 : 2013 | POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 1: PLANNING OF ANALOGUE AND DIGITAL POWER LINE CARRIER SYSTEMS OPERATING OVER EHV/HV/MV ELECTRICITY GRIDS |
NF EN 61850-3 : 2014 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 3: GENERAL REQUIREMENTS |
IEEE 1901-2010 | IEEE Standard for Broadband over Power Line Networks: Medium Access Control and Physical Layer Specifications |
IEC TS 62700:2014 | DC power supply for notebook computers |
CEI EN 62040-2 : 2006 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
SAE J 551/1 : 2015 | PERFORMANCE LEVELS AND METHODS OF MEASUREMENT OF ELECTROMAGNETIC COMPATIBILITY OF VEHICLES, BOATS (UP TO 15 M), AND MACHINES (16.6 HZ TO 18 GHZ) |
IEC TS 62257-3:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 3: Project development and management |
I.S. EN 62052-21:2004 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 21: TARIFF AND LOAD CONTROL EQUIPMENT |
I.S. EN 62310-2:2007 | STATIC TRANSFER SYSTEMS (STS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
I.S. EN 61000-6-4:2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
ECMA 358 : 1ED 2004 | ICT PRODUCT RADIATED EMISSIONS: 1-6 GHZ |
I.S. EN 55016-4-2:2011 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 4-2: UNCERTAINTIES, STATISTICS AND LIMIT MODELLING - MEASUREMENT INSTRUMENTATION UNCERTAINTY |
I.S. EN 50156-1:2015 | ELECTRICAL EQUIPMENT FOR FURNACES AND ANCILLARY EQUIPMENT - PART 1: REQUIREMENTS FOR APPLICATION DESIGN AND INSTALLATION |
BS EN 62052-21 : 2004 | ELECTRICITY METERING EQUIPMENT (A.C.) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 21: TARIFF AND LOAD CONTROL EQUIPMENT (IEC 62052-21:2004) |
BS EN 60947-1 : 2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES |
I.S. EN 50470-1:2006 | ELECTRICITY METERING EQUIPMENT (A.C.) - PART 1: GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - METERING EQUIPMENT (CLASS INDEXES A, B AND C) |
BS EN 55103-1 : 2009 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS |
I.S. EN 60651:1994 | SOUND LEVEL METERS (IEC 60651:1979 (EQV)) |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
UNE-EN 55016-4-2:2012 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
I.S. EN 62333-2:2006 | NOISE SUPPRESSION SHEET FOR DIGITAL DEVICES AND EQUIPMENT - PART 2: MEASURING METHODS |
I.S. EN 55013:2013 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 13:2009, (MOD)) |
TS 103 909 : 1.1.1 | POWER LINE TELECOMMUNICATIONS (PLT) NARROW BAND TRANSCEIVERS IN THE RANGE 9 KHZ TO 500 KHZ POWER LINE PERFORMANCE TEST METHOD GUIDE |
EN 1434-4:2015 | Heat meters - Part 4: Pattern approval tests |
BS EN 1434-4 : 2015 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
I.S. EN 1434-4:2015 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
UNE-EN 61000-4-21:2012 | Electromagnetic compatibility (EMC) -- Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
IEC TR 61000-1-6:2012 | Electromagnetic compatibility (EMC) - Part 1-6: General - Guide to the assessment of measurement uncertainty |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
NF EN 61851-22 : 2002 | ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM - PART 22: A.C. ELECTRIC VEHICLE CHARGING STATION |
UNE-EN 1434-4:2016 | Heat meters - Part 4: Pattern approval tests |
PREN 12015 : DRAFT 2012 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS ANS MOVING WALKS - EMISSION |
TR 102 139 : 1.1.1 | COMPATIBILITY OF POTS TERMINAL EQUIPMENT WITH XDSL SYSTEMS |
NF EN 61000-4-20 : 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES |
IEC 60942:2017 | Electroacoustics - Sound calibrators |
PREN 15964 : DRAFT 2009 | BREATH ALCOHOL TEST DEVICES OTHER THAN SINGLE USE DEVICES - REQUIREMENTS AND TEST METHODS |
EN 14236:2007 | Ultrasonic domestic gas meters |
CISPR 25:2016 | Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers |
IEC 62040-2:2016 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
EN 61260:1995/A1:2001 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS |
IEC 60268-4:2014 | Sound system equipment - Part 4: Microphones |
IEC 61000-3-8:1997 | Electromagnetic compatibility (EMC) - Part 3: Limits - Section 8: Signalling on low-voltage electrical installations - Emission levels, frequency bands and electromagnetic disturbance levels |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
AAMI TIR18:2010 | GUIDANCE ON ELECTROMAGNETIC COMPATIBILITY OF MEDICAL DEVICES IN HEALTHCARE FACILITIES |
CISPR 16-2:2003 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
I.S. EN 60947-8:2003 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 8: CONTROL UNITS FOR BUILT-IN THERMAL PROTECTION (PTC) FOR ROTATING ELECTRICAL MACHINES (IEC 60947-8:2003 (EQV)) |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
DIN EN 12016:2013-12 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity |
DIN EN 14236:2008-06 | ULTRASONIC DOMESTIC GAS METERS |
ISO/IEC 11159:1996 | Information technology — Office equipment — Minimum information to be included in specification sheets — Copying machines |
UL 60730-1:5ED 2016-08-03 | Automatic Electrical Controls - Part 1: General Requirements |
EN 60947-3:2009/A2:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015) |
I.S. EN ISO/IEC 11159:1998 | INFORMATION TECHNOLOGY - OFFICE EQUIPMENT - MINIMUM INFORMATION TO BE INCLUDED IN SPECIFICATION SHEETS - COPYING MACHINES |
DIN EN 1434-4:2019-08 | Thermal energy meters - Part 4: Pattern approval tests (includes Amendment A1:2018) |
I.S. EN 12016:2013 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - IMMUNITY |
IEC 60947-2:2016 RLV | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC 60942:2017 RLV | Electroacoustics - Sound calibrators |
EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
I.S. EN ISO 15254:2009 | OPHTHALMIC OPTICS AND INSTRUMENTS - ELECTRO-OPTICAL DEVICES FOR ENHANCING LOW VISION |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
I.S. EN 14908-2:2014 | OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 2: TWISTED PAIR COMMUNICATION |
BIS IS/ISO 14708-3 : 2008 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 3: IMPLANTABLE NEUROSTIMULATORS |
BS 905-2:1991 | Sound and television broadcast receivers and associated equipment: electromagnetic compatibility Specification for immunity from radio interference of broadcast receivers and associated equipment |
BIS IS/IEC 60947-2 : 2003 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT BREAKERS |
VDE 0805 : 2001 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
UNE-EN 55016-1-2:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements |
I.S. EN 55020:2007 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006) |
07/30167498 DC : 0 | BS EN 61822 - ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - CONSTANT CURRENT REGULATORS |
BS EN 61851-21-1:2017 | Electric vehicle conductive charging system Electric vehicle on-board charger EMC requirements for conductive connection to an AC/DC supply |
ASTM F 3020 : 2016 | Performance Standard for Hand-Worn Metal Detectors Used in Safety and Security |
04/30112602 DC : DRAFT APR 2004 | IEC 62333-2 ED.1 - NOISE SUPPRESSION SHEET FOR DIGITAL DEVICES AND EQUIPMENT - PART 2: MEASURING METHODS |
BS EN 62343-2:2014 | Dynamic modules Reliability qualification |
12/30258326 DC : 0 | BS EN 12015 - ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS ANS MOVING WALKS - EMISSION |
13/30287037 DC : 0 | BS EN 62870 ED. 1.0 - ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - SAFETY SECONDARY CIRCUITS IN SERIES CIRCUITS - GENERAL SAFETY REQUIREMENT |
13/30252768 DC : 0 | BS EN 50121-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
BS EN 62488-1:2013 | Power line communication systems for power utility applications Planning of analogue and digital power line carrier systems operating over EHV/HV/MV electricity grids |
NF EN 60834-1 : 2000 | TELEPROTECTION EQUIPMENT OF POWER SYSTEMS - PERFORMANCE AND TESTING - PART 1: COMMAND SYSTEMS |
03/100589 DC : DRAFT JULY 2003 | IEC 60947-3 AMD 2. ED 2 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS |
11/30242295 DC : 0 | BS EN CISPR 15 AMD.3 ED.7.0 - UPDATE FOLLOWING EDITING COMMITTEE REVIEW, INTRODUCTION OF REQUIREMENTS FOR EMERGENCY FLASHING XENON LAMP LUMINAIRES AND NEON ADVERTISING SIGNS |
02/208921 DC : DRAFT AUG 2002 | IEC 62052-21 ED.1 - ELECTRICITY METERING EQUIPMENT (A.C.) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 21: TARIFF AND LOAD CONTROL EQUIPMENT |
CEI CLC/TR 50484 : 2010 | RECOMMENDATIONS FOR SHIELDED ENCLOSURES |
UNE-EN 62586-1:2014 | Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI) |
TS 136 113 : 13.0.0 | LTE; EVOLVED UNIVERSAL TERRESTRIAL RADIO ACCESS (E-UTRA); BASE STATION (BS) AND REPEATER ELECTROMAGNETIC COMPATIBILITY (EMC) (3GPP TS 36.113 VERSION 14.2.0 RELEASE 14) |
CEI EN 62052-21 : 2005 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 21: TARIFF AND LOAD CONTROL EQUIPMENT |
08/30187038 DC : DRAFT JULY 2008 | BS EN 55016-2-3 AMD1 - SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-3: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - RADIATED DISTURBANCE MEASUREMENTS |
TR 101 562-2 : 1.3.1 | POWERLINE TELECOMMUNICATIONS (PLT); MIMO PLT; PART 2: SETUP AND STATISTICAL RESULTS OF MIMO PLT EMI MEASUREMENTS |
PD CISPR/TR 16-2-5:2008 | Specification for radio disturbance and immunity measuring apparatus and methods In situ measurements of disturbing emissions produced by physically large equipment |
EN 61851-21:2002 | Electric vehicle conductive charging system - Part 21: Electric vehicle requirements for conductive connection to an a.c/d.c. supply |
BS EN 61851-22:2002 | Electric vehicle conductive charging system A.C. electric vehicle charging station |
16/30338981 DC : 0 | BS EN 60934 - CIRCUIT-BREAKERS FOR EQUIPMENT (CBE) |
07/30163348 DC : 0 | BS EN 60255-26 - MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS |
DD IEC TS 62257-3 : DRAFT 2004 | RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 3: PROJECT DEVELOPMENT AND MANAGEMENT |
TS 102 874-6 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); EXTERNAL COMMON POWER SUPPLY FOR CUSTOMER PREMISES NETWORK AND ACCESS EQUIPMENT; PART 6: CPS TYPE 2.D IMPLEMENTATION DETAILS |
EG 202 290 : 1.1.1 FINAL DRAFT | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); MEASUREMENT UNCERTAINTIES AND TEST METHODOLOGIES FROM 1 GHZ TO 40 GHZ |
PD IEC/TR 61000-1-6:2012 | Electromagnetic compatibility (EMC) General. Guide to the assessment of measurement uncertainty |
06/30157139 DC : 0 | |
UNE-EN 13637:2016 | Building hardware - Electrically controlled exit systems for use on escape routes - Requirements and test methods |
BS EN 50121-3-2:2016 | Railway applications. Electromagnetic compatibility Rolling stock. Apparatus |
14/30298039 DC : 0 | BS EN 61069-7 ED 2.0 - INDUSTRIAL-PROCESS MEASUREMENT AND CONTROL - EVALUATION OF SYSTEM PROPERTIES FOR THE PURPOSE OF SYSTEM ASSESSMENT - PART 7: ASSESSMENT OF SYSTEM SAFETY HAZARD |
PD IEC/TS 62257-3:2015 | Recommendations for renewable energy and hybrid systems for rural electrification Project development and management |
10/30235496 DC : 0 | BS EN 50065-1 - SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148.5 KHZ - PART 1: GENERAL REQUIREMENTS, FREQUENCY BANDS AND ELECTROMAGNETIC DISTURBANCES |
CEI EN 55014-2 : 2016 | ELECTROMAGNETIC COMPATIBILITY - REQUIREMENTS FOR HOUSEHOLD APPLIANCES, ELECTRIC TOOLS AND SIMILAR APPARATUS - PART 2: IMMUNITY - PRODUCT FAMILY STANDARD |
CEI EN 61812-1 : 2012 | TIME RELAYS FOR INDUSTRIAL AND RESIDENTIAL USE - PART 1: REQUIREMENTS AND TESTS |
I.S. EN 13637:2015 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
IEC 61851-22:2001 | Electric vehicle conductive charging system - Part 22: AC electric vehicle charging station |
UNE-EN 50121-2:2017 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
BS EN 50463:2007 | Railway applications. Energy measurement on board trains |
CSA ISO/IEC 8802-5 : 2002 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
PD CLC/TR 50538:2010 | Guide to EMC Directive conformity of equipment designed for military purposes |
PREN 50293 : DRAFT 2011 | ELECTROMAGNETIC COMPATIBILITY - ROAD TRAFFIC SIGNAL SYSTEMS |
16/30332623 DC : 0 | BS EN 62920 ED 1.0 - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT APPLYING TO PHOTOVOLTAIC POWER GENERATING SYSTEMS |
BS EN 60255-25:2000 | Electrical relays Electromagnetic emission tests for measuring relays and protection equipment |
BS EN 50133-1:1997 | Alarm systems. Access control systems for use in security applications System requirements |
BS EN 50082-2 : 2012 | ELECTROMAGNETIC COMPATIBILITY - GENERIC IMMUNITY STANDARD - INDUSTRIAL ENVIRONMENT |
CSA C61000-6-1 : 2009 : R2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
UNE-EN 55024:2011 | Information technology equipment - Immunity characteristics - Limits and methods of measurement |
BS ISO/IEC TR 11802-4:1994 | Information technology. Telecommunications and information exchange between systems. Local and metropolitan area networks.Technical reports and guidelines Token ring access method and physical layer specifications. Fibre optic station attachment |
NF EN 50121-3-2 : 2017 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 3-2: ROLLING STOCK - APPARATUS |
BS ISO 8802-12 : 1998 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - DEMAND-PRIORITY ACCESS METHOD, PHYSICAL LAYER AND REPEATER SPECIFICATIONS |
UNI CEN/TS 13149-8 : 2013 | PUBLIC TRANSPORT - ROAD VEHICLE SCHEDULING AND CONTROL SYSTEMS - PART 8: PHYSICAL LAYER FOR IP COMMUNICATION |
BS EN 50136-2-1:1998 | Alarm systems. Alarm transmission systems and equipment General requirements for alarm transmission equipment |
CSA CEI/IEC CISPR 13 : 2009 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
BS EN 61800-3 : 2004 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS |
IEC TS 62370:2004+AMD1:2017 CSV | Electroacoustics - Instruments for the measurement of sound intensity - Electromagnetic and electrostatic compatibility requirements and test procedures |
NF EN 62052-11 : 2003 AMD 1 2017 | ELECTRICITY METERING EQUIPMENT (A.C.) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 11: METERING EQUIPMENT |
CEI EN 50470-1 : 2007 | ELECTRICITY METERING EQUIPMENT (A.C.) - PART 1: GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - METERING EQUIPMENT (CLASS INDEXES A, B AND C) |
BS EN 55020 : 2007 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
I.S. EN 50550:2011 | POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
NF EN 60761-3 : 2005 | EQUIPMENT FOR CONTINUOUS MONITORING RADIOACTIVITY IN GASEOUS EFFLUENTS - PART 3: SPECIFIC REQUIREMENTS FOR RADIOACTIVE NOBLE GAS MONITORS |
I.S. EN 55016-1-1:2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS |
BS EN 55013:2013 | Sound and television broadcast receivers and associated equipment. Radio disturbance characteristics. Limits and methods of measurement |
I.S. ETS 300 327:1995 | SATELLITE EARTH STATIONS AND SYSTEMS (SES) - SATELLITE NEWS GATHERING (SNG) TRANSPORTABLE EARTH STATIONS (TESS) (13-14/11-12 GHZ) |
I.S. CLC/TS 50217:2005 | GUIDE FOR IN SITU MEASUREMENTS - IN SITU MEASUREMENT OF DISTURBANCE EMISSION |
CISPR 16-1-1:2015 RLV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
I.S. EN 50065-2-1:2003 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-1: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRIAL ENVIRONMENTS |
BS EN 61000-6-4 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
BS EN 55016-1-1 : 2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS |
BS EN 60934 : 2001 | CIRCUIT-BREAKERS FOR EQUIPMENT (CBE) |
BS EN 50173-1:2011 | Information technology. Generic cabling systems General requirements |
I.S. EN 14236:2007 | ULTRASONIC DOMESTIC GAS METERS |
I.S. EN 61439-1:2011 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (IEC 61439-1:2011) |
I.S. EN 61326:1998 | |
CEI EN 50090-9-1 : 2005 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 9-1: INSTALLATION REQUIREMENTS - GENERIC CABLING FOR HBES CLASS 1 TWISTED PAIR |
DD ENV 14236:2002 | Ultrasonic domestic gas meters |
PREN 1434-4 : DRAFT 2014 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
I.S. EN 61851-21-1:2017 | ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM - PART 21-1: ELECTRIC VEHICLE ON-BOARD CHARGER EMC REQUIREMENTS FOR CONDUCTIVE CONNECTION TO AN AC/DC SUPPLY |
BS EN 50121-2:2017 | Railway applications. Electromagnetic compatibility Emission of the whole railway system to the outside world |
I.S. EN 55032:2016 | ELECTROMAGNETIC COMPATIBILITY OF MULTIMEDIA EQUIPMENT - EMISSION REQUIREMENTS |
I.S. EN 61036:1997 | ALTERNATING CURRENT STATIC WATT-HOUR METERS FOR ACTIVE ENERGY (CLASSES 1 AND 2) |
EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
PREN 50121-3-2 : DRAFT 2016 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 3-2: ROLLING STOCK - APPARATUS |
VDE 0557-3 : 2001 COR 1 2004 | LOW-VOLTAGE POWER SUPPLIES, D.C. OUTPUT - PART 3: PRODUCT EMC STANDARD |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
I.S. EN 50529-2:2010 | EMC NETWORK STANDARD - PART 2: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING COAXIAL CABLES |
I.S. EN 62488-1:2013 | POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 1: PLANNING OF ANALOGUE AND DIGITAL POWER LINE CARRIER SYSTEMS OPERATING OVER EHV/HV/MV ELECTRICITY GRIDS (IEC 62488-1:2012 (EQV)) |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
IEC 60730-2-17:1997+AMD1:2000+AMD2:2007 CSV | Automatic electrical controls for household and similar use - Part 2-17: Particular requirements for electrically operated gas valves, including mechanical requirements |
I.S. EN 61672-2:2013 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
I.S. EN 50463:2007 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS |
I.S. EN 62041:2010 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - EMC REQUIREMENTS |
CISPR TR 16-4-4:2007 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services |
I.S. EN 60947-2:2017 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS |
DIN EN 12015:2014-09 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission; German version EN 12015:2014 |
IEC 61038:1990+AMD1:1996+AMD2:1998 CSV | Electricity metering - Tariff and load control - Particular requirements for time switches |
IEC 61260-1:2014 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications |
IEC 60730-2-2:2001+AMD1:2005 CSV | Automatic electrical controls for household and similar use - Part 2-2: Particular requirements for thermal motor protectors |
IEC 60255-25:2000 | Electrical relays - Part 25: Electromagnetic emission tests for measuring relays and protection equipment |
UNI EN 12015 : 2014 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - EMISSION |
EN 12015:2014 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission |
EN 55016-4-2:2011/A1:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 4-2: UNCERTAINTIES, STATISTICS AND LIMIT MODELLING - MEASUREMENT INSTRUMENTATION UNCERTAINTY |
UNE-EN 60730-1:2013 | Automatic electrical controls for household and similar use - Part 1: General requirements |
I.S. EN 12015:2014 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - EMISSION |
UNE-EN 60947-3:2009 | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
UNE-EN 60947-8:2005 | Low-voltage switchgear and controlgear -- Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines |
UNI EN ISO 8041 : 2005 | HUMAN RESPONSE TO VIBRATION - MEASURING INSTRUMENTATION |
UNI EN 12016 : 2013 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - IMMUNITY |
UNI EN 14908-2 : 2014 | OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 2: TWISTED PAIR COMMUNICATION |
EN 50136-2-1 : 98 AMD 1 2001 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2-1: GENERAL REQUIREMENTS FOR ALARM TRANSMISSION EQUIPMENT |
BS ISO 23273-1:2006 | Fuel cell road vehicles. Safety specifications Vehicle functional safety |
BS EN 60268-4:2014 | Sound system equipment Microphones |
NF EN 60947-3 : 2009 AMD 2 2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS |
05/30127272 DC : DRAFT JAN 2005 | EN 1434-4 - HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
BS EN 60870-2-1:1996 | Telecontrol equipment and systems. Operating conditions Power supply and electromagnetic compatibility |
BS EN 50529-2:2010 | EMC network standard Wire-line telecommunications networks using coaxial cables |
17/30352682 DC : 0 | BS IEC 60268-4 ED6.0 - SOUND SYSTEM EQUIPMENT - PART 4: MICROPHONES |
PREN 14908-2 : DRAFT 2012 | OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 2: TWISTED PAIR COMMUNICATION |
BS EN 60834-1:2000 | Teleprotection equipment of power systems. Performance and testing Command systems |
TR 134 926 : 13.0.0 | UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM (UMTS); LTE; ELECTROMAGNETIC COMPATIBILITY (EMC); TABLE OF INTERNATIONAL REQUIREMENTS FOR MOBILE TERMINALS AND ANCILLARY EQUIPMENT (3GPP TR 34.926 VERSION 14.0.0 RELEASE 14) |
NF EN 61000-6-1 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
BS EN 60804:2001 | Integrating-averaging sound level meters |
05/30136667 DC : DRAFT JUL 2005 | IEC 61000-6-3 ED 2 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
13/30285941 DC : 0 | BS EN 62041 - SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - EMC REQUIREMENTS |
05/30136673 DC : DRAFT JUL 2005 | IEC 61000-6-4 ED 2 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
I.S. EN ISO 8041:2005 | HUMAN RESPONSE TO VIBRATION - MEASURING INSTRUMENTATION |
NF EN 61000-6-4 : 2007 AMD 1 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
PD CLC/TR 50484:2009 | Recommendations for shielded enclosures |
IEEE 1909.1-2014 | IEEE Recommended Practice for Smart Grid Communications Equipment -- Test Methods and Installation Requirements |
IEEE 802.3U : 1995 | LOCAL AND METROPOLITAN AREA NETWORKS: SUPPLEMENT TO CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS: MEDIA ACCESS CONTROL (MAC) PARAMETERS, PHYSICAL LAYER, MEDIUM ATTACHMENT UNITS, AND REPEATER FOR 100 MB/S OPERATION, TYPE 100 BASE T (CLAUSE 21-30) |
BS EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) Generic standards. Immunity for residential, commercial and light-industrial environments |
I.S. EN 61000-4-21:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-21: TESTING AND MEASUREMENT TECHNIQUES - REVERBERATION CHAMBER TEST METHODS |
ISO/IEC 14575:2000 | Information technology — Microprocessor systems — Heterogeneous InterConnect (HIC) (Low-Cost, Low-Latency Scalable Serial Interconnect for Parallel System Construction) |
13/30274535 DC : 0 | BS ISO 11451-1 - ROAD VEHICLES - VEHICLE TEST METHODS FOR ELECTRICAL DISTURBANCES FROM NARROWBAND RADIATED ELECTROMAGNETIC ENERGY - PART 1: GENERAL PRINCIPLES AND TERMINOLOGY |
13/30280680 DC : 0 | BS EN 60947-3:2009+A1:2012+A2 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS |
14/30291768 DC : 0 | BS EN 1434-4 - HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
BS EN 55016-4-2 : 2011 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 4-2: UNCERTAINTIES, STATISTICS AND LIMIT MODELLING - MEASUREMENT INSTRUMENTATION UNCERTAINTY |
NF EN 62041 : 2011 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - EMC REQUIREMENTS |
I.S. EN 61000-6-3:2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006 (EQV)) |
DIN EN 61268 : 1996 | ALTERNATING CURRENT STATIC VAR-HOUR METERS FOR REACTIVE ENERGY (CLASSES 2 AND 3) |
PD IEC/TS 62700:2014 | DC power supply for notebook computers |
18/30368636 DC : 0 | BS EN 12016 - ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - IMMUNITY |
CEI EN 62041 : 2012 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - EMC REQUIREMENTS |
BS EN ISO 8041-1:2017 | Human response to vibration. Measuring instrumentation General purpose vibration meters |
13/30292662 DC : 0 | BS EN 61260-2 ED.1.0 - ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN EVALUATION TESTS |
BS EN 62310-2:2007 | Static transfer systems (STS) Electromagnetic compatibility (EMC) requirements |
I.S. EN 61260-1:2014 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 1: SPECIFICATIONS |
BS EN 61204-3:2001 | Low voltage power supplies, d.c. output Electromagnetic compatibility (EMC) |
BS EN 50083-2 : 2012 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT |
BS EN 62041:2010 | Safety of transformers, reactors, power supply units and combinations thereof. EMC requirements |
CLC/TR 50083-10-1:2014 | Cable networks for television signals, sound signals and interactive services - Part 10-1: Guidelines for the implementation of return paths in cable networks |
97/207801 DC : DRAFT JUL 1997 | IEC 62026-5 - CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5: SMART DISTRIBUTED SYSTEM (SDS) |
14/30292140 DC : 0 | BS EN 62040-2 ED3.0 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS (EMC) |
11/30241988 DC : 0 | BS EN 50561-1 - POWER LINE COMMUNICATION APPARATUS USED IN LOW VOLTAGE INSTALLATIONS - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - PART 1: APPARATUS FOR IN-HOME USE |
14/30297223 DC : 0 | BS EN 61000-6-2 ED -3 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS |
04/19986707 DC : 0 | BS EN 1804-4 - MACHINES FOR UNDERGROUND MINES - SAFETY REQUIREMENTS FOR HYDRAULIC POWERED ROOF SUPPORTS - PART 4: ELECTRO-HYDRAULIC CONTROL SYSTEMS |
09/30202737 DC : 0 | BS EN 15964 - BREATH ALCOHOL TEST DEVICES OTHER THAN SINGLE USE DEVICES - REQUIREMENTS AND TEST METHODS |
DIN EN 50082-1 : 1997 | ELECTROMAGNETIC COMPATIBILITY (EMC) - GENERIC IMMUNITY STANDARD - PART 1: RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRY |
BS EN 61000-4-21:2011 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Reverberation chamber test methods |
BS EN 61260:1996 | Electroacoustics. Octave-band and fractional-octave-band filters |
BS EN 50098-1:1999 | Customer premises cabling for information technology ISDN basic access |
CSA CISPR 16-2-3 : 2012 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-3: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - RADIATED DISTURBANCE MEASUREMENTS |
AAMI ISO 14708-4 : 2008 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 4: IMPLANTABLE INFUSION PUMPS |
BS EN 61326:1998 | Electrical equipment for measurement, control and laboratory use. EMC requirements |
15/30327720 DC : 0 | BS EN 62586-1 - POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI) |
DIN EN 50081-1 : 1993 | ELECTROMAGNETIC COMPATIBILITY (EMC) - GENERIC EMISSION STANDARD - PART 1: RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRY |
CEI EN 50173-1 : 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
PD CISPR/TR 16-4-3:2004 | Specification for radio disturbance and immunity measuring apparatus and methods Uncertainties, statistics and limit modelling. Statistical considerations in the determination of EMC compliance of mass-produced products |
EN 50121-3-2:2016 | Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
CEI EN 61000-6-1 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
TS 137 113 : 13.1.0 | DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+) (GSM); UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM (UMTS); LTE; E-UTRA, UTRA AND GSM/EDGE; MULTI-STANDARD RADIO (MSR) BASE STATION (BS) ELECTROMAGNETIC COMPATIBILITY (EMC) (3GPP TS 37.113 VERSION 14.2.0 RELEASE 14) |
SCTE 203 : 2014 | PRODUCT ENVIRONMENTAL REQUIREMENTS FOR CABLE TELECOMMUNICATIONS FACILITIES - TEST METHODS |
BS EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods Methods of measurement of disturbances and immunity. Radiated disturbance measurements |
CEI EN 61850-3 : 2014 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 3: GENERAL REQUIREMENTS |
TS 136 124 : 13.1.0 | LTE; EVOLVED UNIVERSAL TERRESTRIAL RADIO ACCESS (E-UTRA); ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS FOR MOBILE TERMINALS AND ANCILLARY EQUIPMENT (3GPP TS 36.124 VERSION 14.1.0 RELEASE 14) |
BS EN 60947-3 : 2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS |
IEEE 475-2000 | IEEE Standard Measurement Procedure for Field Disturbance Sensors 300 MHz to 40 GHz |
EN 62488-2:2017 | Power line communication systems for power utility applications - Part 2: Analogue power line carrier terminals or APLC |
IEEE 1901.2-2013 | IEEE Standard for Low-Frequency (less than 500 kHz) Narrowband Power Line Communications for Smart Grid Applications |
I.S. HD 60364-5-51:2009 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES (IEC 60364-5-51:2005 (MOD)) |
TS 125 113 : 13.0.1 | UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM (UMTS); BASE STATION (BS) AND REPEATER ELECTROMAGNETIC COMPATIBILITY (EMC) (3GPP TS 25.113 VERSION 13.1.0 RELEASE 13) |
BS EN 50470-1 : 2006 | ELECTRICITY METERING EQUIPMENT (A.C.) - PART 1: GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - METERING EQUIPMENT (CLASS INDEXES A, B AND C) |
ISO 14302:2002 | Space systems Electromagnetic compatibility requirements |
BS EN 55016-1-2:2014 | Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus. Coupling devices for conducted disturbance measurements |
UNE-EN 61822:2011 | Electrical installations for lighting and beaconing of aerodromes - Constant current regulators |
I.S. EN 50065-1:2011 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 1: GENERAL REQUIREMENTS, FREQUENCY BANDS AND ELECTROMAGNETIC DISTURBANCES |
INCITS/ISO/IEC 15404 : 2008 | INFORMATION TECHNOLOGY - OFFICE MACHINES - MINIMUM INFORMATION TO BE INCLUDED IN SPECIFICATION SHEETS - FACSIMILE EQUIPMENT |
S.R. CEN/TS 13149-8:2013 | PUBLIC TRANSPORT - ROAD VEHICLE SCHEDULING AND CONTROL SYSTEMS - PART 8: PHYSICAL LAYER FOR IP COMMUNICATION |
ISO/IEC 8802-4:1990 | Information processing systems — Local area networks — Part 4: Token-passing bus access method and physical layer specifications |
I.S. EN 50428:2005 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - COLLATERAL STANDARD - SWITCHES AND RELATED ACCESSORIES FOR USE IN HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) |
I.S. EN 50498:2010 | |
S.R. CWA 16688:2013 | BATTERY SWAP SYSTEMS INTERFACES FOR ELECTRIC VEHICLES |
I.S. EN 62870:2015 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - SAFETY SECONDARY CIRCUITS IN SERIES CIRCUITS - GENERAL SAFETY REQUIREMENTS |
I.S. EN 61812-1:2011 | TIME RELAYS FOR INDUSTRIAL AND RESIDENTIAL USE - PART 1: REQUIREMENTS AND TESTS |
BIS IS/IEC 60730-1 : 1999(R2006) | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 1: GENERAL REQUIREMENTS |
ISO 14708-4:2008 | Implants for surgery Active implantable medical devices Part 4: Implantable infusion pumps |
ISO/IEC 14908-2:2012 | Information technology — Control network protocol — Part 2: Twisted pair communication |
CEI UNI EN 12414 : 2001 | VEHICLE PARKING CONTROL EQUIPMENT - PAY AND DISPLAY TICKET MACHINE - TECHNICAL AND FUNCTIONAL REQUIREMENTS |
CEI EN 50083-8 : 2014 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 8: ELECTROMAGNETIC COMPATIBILITY FOR NETWORKS |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
CEI EN 62310-2 : 2007 | STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
EN 50550:2011/A1:2014 | POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
UNE-EN 50498:2011 | Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
CISPR 32:2015 RLV | Electromagnetic compatibility of multimedia equipment - Emission requirements |
ISO 23273-1:2006 | Fuel cell road vehicles Safety specifications Part 1: Vehicle functional safety |
I.S. EN 61850-3:2014 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 3: GENERAL REQUIREMENTS |
I.S. EN 60730-1:2016 | AUTOMATIC ELECTRICAL CONTROLS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 55025:2017 | VEHICLES, BOATS AND INTERNAL COMBUSTION ENGINES - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT FOR THE PROTECTION OF ON-BOARD RECEIVERS |
I.S. ETS 300 159:1993 | SATELLITE EARTH STATIONS (SES); TRANSMIT/RECEIVE VERY SMALL APERTURE TERMINALS (VSATS) USED FOR DATA COMMUNICATIONS OPERATING IN THE FIXED SATELLITE SERVICE (FSS) 11/12/14 GHZ FREQUENCY BANDS |
I.S. CWA 14642:2003 | CEN WORKSHOP AGREEMENT (CWA) - ELECTRICAL INTERFACE FOR DOMESTIC COGENERATION - REQUIREMENTS FOR DISTRIBUTION NETWORK CONNECTION FOR MICRO COGENERATION SYSTEMS FOR DOMESTIC USE UP TO 16 A PER PHASE IN LOW-VOLTAGE DISTRIBUTION NETWORKS |
I.S. EN 50083-2:2012 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT |
I.S. EN 60255-25:2001 | ELECTRICAL RELAYS - PART 25: ELECTROMAGNETIC EMISSION TESTS FOR MEASURING RELAYS AND PROTECTION EQUIPMENT |
I.S. EN 61000-4-20:2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES |
IEC 62310-2:2006 | Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
CISPR TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests |
I.S. EN 60947-3:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS |
I.S. EN 62040-2:2006 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS |
I.S. ETR 077:2002 | SATELLITE EARTH STATIONS AND SYSTEMS (SES); SPURIOUS RADIATION LIMITS TO AND FROM SATELLITE EARTH STATIONS, VERY SMALL APERTURE TERMINALS (VSATS) AND TELEVISION RECEIVE ONLY (TVRO) |
I.S. EN 61822:2009 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - CONSTANT CURRENT REGULATORS |
IEC 61851-21-1:2017 | Electric vehicle conductive charging system - Part 21-1 Electric vehicle on-board charger EMC requirements for conductive connection to AC/DC supply |
IEC 61204-3:2016 | Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
EN 62333-2:2006/A1:2015 | NOISE SUPPRESSION SHEET FOR DIGITAL DEVICES AND EQUIPMENT - PART 2: MEASURING METHODS (IEC 62333-2:2006/A1:2015) |
EN 61260-2:2016/A1:2017 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS (IEC 61260-2:2016/A1:2017) |
IEC 62052-21:2004+AMD1:2016 CSV | Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 21: Tariff and load control equipment |
IEC 62870:2015 | Electrical installations for lighting and beaconing of aerodromes - Safety secondary circuits in series circuits - General safety requirements |
12/30266531 DC : 0 | BS EN TS 62257-1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 1: GENERAL INTRODUCTION TO RURAL ELECTRIFICATION |
04/30123347 DC : DRAFT OCT 2004 | IEC 61439-1 - LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES |
BS EN 60730-1:2011 | Automatic electrical controls for household and similar use General requirements |
CISPR 61000-6-3:1996 | Electromagnetic compatibility (EMC) - Part 6: Generic standards - Section 3: Emission standard for residential, commercial and light-industrial environments |
IEC 62052-11:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 11: Metering equipment |
BS EN 60947-2:2017+A1:2020 | Low-voltage switchgear and controlgear Circuit-breakers |
IEC 60804:2000 | Integrating-averaging sound level meters |
IEC 60255-26:2013 | Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirements |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
IEC 60947-8:2003+AMD1:2006+AMD2:2011 CSV | Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines |
BS EN 14236:2007 | Ultrasonic domestic gas meters |
BS EN 50428 : 2005 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - COLLATERAL STANDARD - SWITCHES AND RELATED ACCESSORIES FOR USE IN HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) |
BS EN ISO 15254:2009 | Ophthalmic optics and instruments. Electro-optical devices for enhancing low vision |
UNE-EN 61000-4-20:2011 | Electromagnetic compatibility (EMC) -- Part 4-20: Testing and measurement techniques - Emission and immunity testing in Transverse Electromagnetic (TEM) waveguides - Basic EMC publication |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
IEC 62333-2:2006+AMD1:2015 CSV | Noise suppression sheet for digital devices and equipment - Part 2:Measuring methods |
CISPR 20:2006+AMD1:2013 CSV | Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement |
14/30315309 DC : 0 | BS EN 61204-3 - LOW VOLTAGE POWER SUPPLIES, D.C. OUTPUT - PART 3: ELECTROMAGNETIC COMPATIBILITY (EMC) |
09/30204029 DC : 0 | BS EN 61439-1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES |
UNE-EN 12016:2014 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity |
IEC 61069-7:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 7: Assessment of system safety |
CISPR 24:2010+AMD1:2015 CSV | Information technology equipment - Immunity characteristics - Limitsand methods of measurement |
UNE-EN 50065-2-3:2004 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz -- Part 2-3: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors |
IEC 61850-3:2013 | Communication networks and systems for power utility automation - Part 3: General requirements |
IEC 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
BS EN 12016:2013 | Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks. Immunity |
IEC 60835-3-13:1996 | Methods of measurement for equipment used in digital microwave radio transmission systems - Part 3: Measurement on satellite earth stations - Section 13: VSAT systems |
IEC 60730-2-8:2000+AMD1:2002+AMD2:2015 CSV | Automatic electrical controls for household and similar use - Part 2-8: Particular requirements for electrically operated watervalves, including mechanical requirements |
UNE-HD 60364-5-51:2010 | Electrical installations of buildings -- Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 61252:1993+AMD1:2000+AMD2:2017 CSV | Electroacoustics - Specifications for personal sound exposure meters |
ISO 15254:2009 | Ophthalmic optics and instruments Electro-optical devices for enhancing low vision |
IEC 60730-2-19:1997+AMD1:2000+AMD2:2007 CSV | Automatic electrical controls for household and similar use - Part 2-19: Particular requirements for electrically operated oil valves, including mechanical requirements |
UNE-EN 50550:2012 | Power frequency overvoltage protective device for household and similar applications (POP) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
UNE-EN 61000-6-4:2007 | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
11/30233799 DC : 0 | BS EN 60730-1 ED5 - AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 1: GENERAL REQUIREMENTS |
09/30212624 DC : 0 | BS EN 50550 - POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
IEC 61439-1:2020 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
BS EN 50156-1:2015 | Electrical equipment for furnaces and ancillary equipment Requirements for application design and installation |
IEC 62488-1:2012 | Power line communication systems for power utility applications - Part 1: Planning of analogue and digital power line carrier systems operating over EHV/HV/MV electricity grids |
ISO 8041-1:2017 | Human response to vibration — Measuring instrumentation — Part 1: General purpose vibration meters |
IEC 61260-2:2016+AMD1:2017 CSV | Electroacoustics - Octave-band and fractional-octave band filters - Part 2: Pattern evaluation tests |
IEC 60870-2-1:1995 | Telecontrol equipment and systems - Part 2: Operating conditions - Section 1: Power supply and electromagnetic compatibility |
12/30260546 DC : 0 | BS EN 50156-1 - ELECTRICAL EQUIPMENT FOR FURNACES AND ANCILLARY EQUIPMENT - PART 1: REQUIREMENTS FOR APPLICATION DESIGN AND INSTALLATION |
UNE-EN 50065-1:2012 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
UNE-EN 50561-1:2014 | Power line communication apparatus used in low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement - Part 1: Apparatus for in-home use |
BS EN ISO/IEC 11159:1998 | Information technology. Office equipment. Minimum information to be included in specification sheets. Copying machines |
EN 61204-3:2000 | Low voltage power supplies, d.c. output - Part 3: Electromagnetic compatibility (EMC) |
EN 13637:2015 | Building hardware - Electrically controlled exit systems for use on escape routes - Requirements and test methods |
EN ISO/IEC 11159 : 1998 | INFORMATION TECHNOLOGY - OFFICE EQUIPMENT - MINIMUM INFORMATION TO BE INCLUDED IN SPECIFICATION SHEETS - COPYING MACHINES |
EN 14908-2:2014 | Open Data Communication in Building Automation, Controls and Building Management - Control Network Protocol - Part 2: Twisted Pair Communication |
EN ISO 8041-1:2017 | Human response to vibration - Measuring instrumentation - Part 1: General purpose vibration meters (ISO 8041-1:2017) |
07/30165539 DC : 0 | |
12/30159217 DC : 0 | BS EN 60601-1-2 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES - REQUIREMENTS AND TESTS |
ECMA/TR 97 : 1ED 2009 | GUIDE FOR ASSESSMENT OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS FROM MULTIMEDIA PRODUCTS IN ACCORDANCE WITH IEC/EN 62311 |
NF EN 62052-21 : 2006 | ELECTRICITY METERING EQUIPMENT (A.C.) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 21: TARIFF AND LOAD CONTROL EQUIPMENT |
BS EN 50529-1:2010 | EMC network standard Wire-line telecommunications networks using telephone wires |
BIS IS/IEC 60947-3 : 1999 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE COMBINATION UNITS |
CEI EN 61260-1 : 2017 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 1: SPECIFICATIONS |
BS ISO/IEC/IEEE 8802-3:2017 | Information technology. Telecommunications and information exchange between systems. Local and metropolitan area networks. Specific requirements Standard for Ethernet |
BS 7573-3.13(1997) : 1997 | METHODS OF MEASUREMENT FOR EQUIPMENT USED IN DIGITAL MICROWAVE RADIO TRANSMISSION SYSTEMS - MEASUREMENTS ON SATELLITE EARTH STATIONS - PART 3-13: VSAT SYSTEMS |
ISO/IEC 14709-2:1998 | Information technology Configuration of customer premises cabling (CPC) for applications Part 2: Integrated Services Digital Network (ISDN) primary rate |
I.S. EN 50173-1:2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
BS EN 62488-2:2017 | Power line communication systems for power utility applications Analogue power line carrier terminals or APLC |
02/203205 DC : DRAFT FEB 2002 | IEC 61514-2. ED.1 - INDUSTRIAL PROCESS CONTROL SYSTEMS - PART 2: METHODS OF EVALUATING THE PERFORMANCE OF INTELLIGENT VALVE POSITIONERS WITH PNEUMATIC OUTPUTS |
EN 61851-22:2002 | Electric vehicle conductive charging system - Part 22: AC electric vehicle charging station |
CEI EN 50256 : 1999 | CHARACTERISTICS OF DVB RECEIVERS |
EN IEC 60942:2018 | Electroacoustics - Sound calibrators |
PREN 12016 : DRAFT 2018 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR LIFTS, ESCALATORS AND MOVING WALKS - IMMUNITY |
CEI EN 50098-2 : 1997 | CUSTOMER PREMISES CABLING FOR INFORMATION TECHNOLOGY - PART 2: 2048 KBIT/S ISDN PRIMARY ACCESS AND LEASED LINE NETWORK INTERFACE |
03/311729 DC : DRAFT JULY 2003 | EN ISO 8041 - HUMAN RESPONSE TO VIBRATION - MEASURING INSTRUMENTATION |
CEI EN 50065-1 : 2012 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 1: GENERAL REQUIREMENTS, FREQUENCY BANDS AND ELECTROMAGNETIC DISTURBANCES |
09/30208590 DC : 0 | BS EN 61672-2 ED.2 - ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
PD CLC/TR 50485:2010 | Electromagnetic compatibility. Emission measurements in fully anechoic chambers |
PREN 50065-1 : DRAFT 2010 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148.5 KHZ - PART 1: GENERAL REQUIREMENTS, FREQUENCY BANDS AND ELECTROMAGNETIC DISTURBANCES |
BS EN 61850-3:2014 | Communication networks and systems for power utility automation General requirements |
I.S. EN 50529-1:2010 | EMC NETWORK STANDARD - PART 1: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING TELEPHONE WIRES |
14/30297218 DC : 0 | BS EN 61000-6-1 ED.3 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
PREN 50561-1 : DRAFT 2011 | POWER LINE COMMUNICATION APPARATUS USED IN LOW VOLTAGE INSTALLATIONS - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - PART 1: APPARATUS FOR IN-HOME USE |
SAE J 1113/1 : 2013 | ELECTROMAGNETIC COMPATIBILITY MEASUREMENT PROCEDURES AND LIMITS FOR COMPONENTS OF VEHICLES, BOATS (UP TO 15 M), AND MACHINES (EXCEPT AIRCRAFT) (16.6 HZ TO 18 GHZ) |
BS EN 50065-2-1:2003 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments |
97/209093 DC : 0 | |
BS EN 60947-8:2003 | Low-voltage switchgear and controlgear Control units for built-in thermal protection (PTC) for rotating electrical machines |
PD CLC/TR 50083-10-1:2014 | Cable networks for television signals, sound signals and interactive services Guidelines for the implementation of return paths in cable networks |
BS EN 55025:2017 | Vehicles, boats and internal combustion engines - Radio disturbance characteristics. Limits and methods of measurement for the protection of on-board receivers |
03/313373 DC : DRAFT AUG 2003 | IEC 60770-3 ED.1 - TRANSMITTERS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 3: METHODS FOR EVALUATION OF INTELLIGENT TRANSMITTERS |
BS EN 61038:1993 | Specification for time switches for tariff and load control |
CEI CLC/TR 50485 : 2013 | ELECTROMAGNETIC COMPATIBILITY - EMISSION MEASUREMENTS IN FULLY ANECHOIC CHAMBERS |
00/243920 DC : DRAFT AUG 2000 | CISPR 20. ED. 5. SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
BS EN 61822:2009 | Electrical installations for lighting and beaconing of aerodromes. Constant current regulators |
TS 102 578 : 1.2.1 | POWERLINE TELECOMMUNICATIONS (PLT); COEXISTENCE BETWEEN PLT MODEMS AND SHORT WAVE RADIO BROADCASTING SERVICES |
NF EN 60255-25 : 2001 | ELECTRICAL RELAYS - PART 25: ELECTROMAGNETIC EMISSION TESTS FOR MEASURING RELAYS AND PROTECTION EQUIPMENT |
00/560888 DC : APR 2000 | IEC 60601-1-2 EDITION 2 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR SAFETY - COLLATERAL STANDARD - ELECTROMAGNETIC COMPATIBILITY - REQUIREMENTS AND TESTS |
BS EN 50491-5-1:2010 | General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) EMC requirements, conditions and test set-up |
I.S. EN 50065-2-3:2003 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-3: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 3 KHZ TO 95 KHZ AND INTENDED FOR USE BY ELECTRICITY SUPPLIERS AND DISTRIBUTORS |
I.S. EN 50121-3-2:2016 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 3-2: ROLLING STOCK - APPARATUS |
10/30240055 DC : DRAFT DEC 2010 | BS EN 60255-26 - MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS |
NF EN 50561-1 : 2014 | POWER LINE COMMUNICATION APPARATUS USED IN LOW-VOLTAGE INSTALLATIONS - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - PART 1: APPARATUS FOR IN-HOME USE |
13/30280815 DC : 0 | BS EN 62343-2 - DYNAMIC MODULES - PART 2: RELIABILITY QUALIFICATION |
PD CEN/TS 13149-8:2013 | Public transport. Road vehicle scheduling and control systems Physical layer for IP communication |
BS EN 60835-3-13:1997 | Methods of measurement for equipment used in digital microwave radio transmission systems. Measurements on satellite earth stations VSAT systems |
NF EN 61260-2 : 2016 AMD 1 2017 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS |
NF EN 55016-4-2 : 2012 AMD 1 2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 4-2: UNCERTAINTIES, STATISTICS AND LIMIT MODELLING - MEASUREMENT INSTRUMENTATION UNCERTAINTY |
00/203618 DC : DRAFT AUG 2000 | IEC 60255-26 - MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS FOR MEASURING RELAYS AND PROTECTION EQUIPMENT |
CEI EN 62052-11 : 2003 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 11: METERING EQUIPMENT |
DIN EN 1434-4:2016-02 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
BS EN 61069-7:2016 | Industrial-process measurement, control and automation. Evaluation of system properties for the purpose of system assessment Assessment of system safety |
AAMI ISO 14708-4:2008(R2011) | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 4: IMPLANTABLE INFUSION PUMPS |
CSA CISPR 16-2-3 : 2012 : R2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-3: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - RADIATED DISTURBANCE MEASUREMENTS |
CSA C900.4 : 2013 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
BS EN 62040-2:2006 | Uninterruptible power systems (UPS) Electromagnetic compatibility (EMC) requirements |
CSA ISO/IEC 8802-3 : 2002 : R2011 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
DIN EN 13637:2015-12 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
I.S. EN ISO 8041-1:2017 | HUMAN RESPONSE TO VIBRATION - MEASURING INSTRUMENTATION - PART 1: GENERAL PURPOSE VIBRATION METERS (ISO 8041-1:2017) |
CSA ISO/IEC 8802-5 : 2002 : INC : AMD 1 : 2002 : R2011 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
CSA ISO/IEC 8802-3 : 2002 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
NF EN 60761-1 : 2005 | EQUIPMENT FOR CONTINUOUS MONITORING RADIOACTIVITY IN GASEOUS EFFLUENTS - PART 1: GENERAL REQUIREMENTS |
NF EN 60761-4 : 2005 | EQUIPMENT FOR CONTINUOUS MONITORING RADIOACTIVITY IN GASEOUS EFFLUENTS - PART 4: SPECIFIC REQUIREMENTS FOR IODINE MONITORS |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R2015 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
I.S. EN 61204-3:2000 | LOW VOLTAGE POWER SUPPLIES, D.C. OUTPUT - PART 3: ELECTROMAGNETIC COMPATIBILITY (EMC) |
CEI EN 50491-5-1 : 2011 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 5-1: EMC REQUIREMENTS, CONDITIONS AND TEST SET-UP |
NF EN 60255-26 : 2014 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS |
I.S. EN 55016-1-2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-2: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - COUPLING DEVICES FOR CONDUCTED DISTURBANCE MEASUREMENTS |
S.R. CLC/TR 50538:2010 | |
I.S. EN 60947-1:2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES |
I.S. EN 60934:2001 | CIRCUIT BREAKERS FOR EQUIPMENT (CBE) (IEC 60934:2000 (EQV)) |
IEEE/ANSI C63.12-2015 | American National Standard Recommended Practice for Electromagnetic Compatibility Limits and Test Levels |
EN 50470-1:2006 | Electricity metering equipment (a.c.) - Part 1: General requirements, tests and test conditions - Metering equipment (class indexes A, B and C) |
I.S. EN 61260-2:2016 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 2: PATTERN-EVALUATION TESTS |
NF EN 61000-6-3 : 2007 AMD 1 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
IEEE/ANSI C63.23-2012 | American National Standard Guide for Electromagnetic Compatibility—Computations and Treatment of Measurement Uncertainty |
IEEE 1775:2010 | POWER LINE COMMUNICATION EQUIPMENT - ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS - TESTING AND MEASUREMENT METHODS |
ISO/IEC TR 11802-4:1994 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Technical reports and guidelines — Part 4: Token ring access method and physical layer specifications — Fibre optic station attachment |
BS EN 50083-8:2013 | Cable networks for television signals, sound signals and interactive services Electromagnetic compatibility for networks |
ANSI S1.40 : 2006 | SPECIFICATIONS AND VERIFICATION PROCEDURES FOR SOUND CALIBRATORS |
BS EN 62052-11 : 2003 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TEST AND TEST CONDITIONS - PART 11: METERING EQUIPMENT (IEC 62052-11:2003) |
CISPR 13:2009+AMD1:2015 CSV | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement |
EN 55025:2017/AC:2017-11 | VEHICLES, BOATS AND INTERNAL COMBUSTION ENGINES - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT FOR THE PROTECTION OF ON-BOARD RECEIVERS (CISPR 25:2016/COR1:2017) |
I.S. EN 55024:2010 | INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
ISO 21750:2006 | Road vehicles — Safety enhancement in conjunction with tyre inflation pressure monitoring |
I.S. EN 60255-26:2013 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS (IEC 60255-26:2013 (EQV)) |
EN 50121-2:2017 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
I.S. EN 61069-7:2016 | INDUSTRIAL-PROCESS MEASUREMENT, CONTROL AND AUTOMATION - EVALUATION OF SYSTEM PROPERTIES FOR THE PURPOSE OF SYSTEM ASSESSMENT - PART 7: ASSESSMENT OF SYSTEM SAFETY |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
UNE 199071-1:2014 | Road traffic management equipment. Environmental sensors on roads. Atmospheric sensors in roads. Part 1: Functional characteristics |
UNE-EN 62041:2011 | Safety of transformers, reactors, power supply units and combinations thereof - EMC requirements |
PREN 50121-2 : DRAFT 2016 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
ANSI S1.40 : 2006 : R2011 | SPECIFICATIONS AND VERIFICATION PROCEDURES FOR SOUND CALIBRATORS |
NF EN 50463 : 2008 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS |
CISPR TR 16-4-3:2004+AMD1:2006 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-3: Uncertainties, statistics and limit modelling - Statistical considerations in the determination of EMC compliance of mass-produced products |
CAN/CSA-CISPR 32:17 | Electromagnetic compatibility of multimedia equipment — Emission requirements (Adopted IEC CISPR 32:2015, second edition, 2015-03, with Canadian deviations) | Compatibilité électromagnétique des équipements multimédia — Exigences d’émission (norme IEC CISPR 32:2015 adoptée, deuxième édition, 2015-03, avec exigences propres au Canada) |
UNE-EN 55013:2013 | Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 63044-5-1:2017 | Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 5-1: EMC requirements, conditions and test set-up |
I.S. EN 50293:2012 | ROAD TRAFFIC SIGNAL SYSTEMS - ELECTROMAGNETIC COMPATIBILITY |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
IEC 62003:2009 | Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing |
ASTM F 3278 : 2017 | Standard Performance Specification for Hand-Held Metal Detectors Used in Safety and Security |
I.S. EN 61000-6-2:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005 (EQV)) |
ISO/IEC/IEEE 8802-3:2017 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Specific requirements — Part 3: Standard for Ethernet |
I.S. EN 50083-8:2013 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 8: ELECTROMAGNETIC COMPATIBILITY FOR NETWORKS |
I.S. EN 60268-4:2014 | SOUND SYSTEM EQUIPMENT - PART 4: MICROPHONES |
IEC 60669-2-5:2013 | Switches for household and similar fixed electrical installations - Part 2-5: Particular requirements - Switches and related accessories for use in home and building electronic systems (HBES) |
IEC 61822:2009 | Electrical installations for lighting and beaconing of aerodromes - Constant current regulators |
I.S. EN 50491-5-1:2010 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 5-1: EMC REQUIREMENTS, CONDITIONS AND TEST SET-UP |
ISO/IEC 24700:2005 | Quality and performance of office equipment that contains reused components |
CISPR TR 16-2-5:2008 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-5: In situ measurements for disturbing emissions produced by physically large equipment |
EN 61800-3 : 2004 AMD 1 2012 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011) |
IEC 62040-2:2016 RLV | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
NF EN 60947-2 : 2006 AMD 2 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS |
IEC 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
UNE-EN 61439-1:2012 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
BS EN 50550 : 2011 | POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
IEC 60834-1:1999 | Teleprotection equipment of power systems - Performance and testing - Part 1: Command systems |
IEC 60934:2000+AMD1:2007+AMD2:2013 CSV | Circuit-breakers for equipment (CBE) |
07/30161287 DC : 0 | BS EN 60947-2 AMD1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS |
IEC 61672-2:2013+AMD1:2017 CSV | Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests |
BS EN 14908-2:2014 | Open Data Communication in Building Automation, Controls and Building Management. Control Network Protocol Twisted Pair Communication |
11/30203695 DC : 0 | BS EN 60669-2-5 - SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-5: SWITCHES AND RELATED ACCESSORIES FOR USE IN HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) |
BS EN 61439-1:2011 | Low-voltage switchgear and controlgear assemblies General rules |
IEC 62343-2:2014 | Dynamic modules - Part 2: Reliability qualification |
ISO 8041:2005 | Human response to vibration Measuring instrumentation |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
BS EN 50090-2-2 : 1997 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-2: SYSTEM OVERVIEW - GENERAL TECHNICAL REQUIREMENTS |
DIN VDE 0805 : 1990 AMD 1 1991 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT |
EN 50065-2-1 : 2003 AMD 1 2005 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-1: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRIAL ENVIRONMENTS |
EN 50065-2-2:2003/A1:2005/corrigendum Oct. 2006 | SIGNALING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-2: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN INDUSTRIAL ENVIRONMENTS |
EN 62488-1:2013 | Power line communication systems for power utility applications - Part 1: Planning of analogue and digital power line carrier systems operating over EHV/HV/MV electricity grids |
EN 61038:1992/A2:1998 | ELECTRICITY METERING - TARIFF AND LOAD CONTROL - PARTICULAR REQUIREMENTS FOR TIME SWITCHES |
EN 12016:2013 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity |
EN 61000-6-3 : 2007 : INC : AMD 1 : 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
EN 61036:1996/A1:2000 | ALTERNATING CURRENT STATIC WATT-HOUR METERS FOR ACTIVE ENERGY (CLASSES 1 AND 2) |
EN 60870-2-1:1996 | Telecontrol equipment and systems - Part 2: Operating conditions - Section 1: Power supply and electromagnetic compatibility |
EN 60934:2001/A2:2013 | CIRCUIT BREAKERS FOR EQUIPMENT (CBE) (IEC 60934:2000/A2:2013) |
EN 61037:1992/A2:1998 | ELECTRONIC METERING - TARIFF AND LOAD CONTROL - PARTICULAR REQUIREMENTS FOR ELECTRONIC RIPPLE CONTROL RECEIVERS |
CISPR 16-2-3:2016 RLV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
CEN/TS 13149-8:2013 | Public transport - Road vehicle scheduling and control systems - Part 8: Physical layer for IP communication |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 50065-2-3 : 2003 AMD 1 2005 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148.5 KHZ - PART 2-3: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 3 KHZ TO 95 KHZ AND INTENDED FOR USE BY ELECTRICITY SUPPLIERS AND DISTRIBUTORS |
EN 50156-1:2015 | Electrical equipment for furnaces and ancillary equipment - Part 1: Requirements for application design and installation |
EN 61326:1997/A3:2003 | |
EN 62870:2015 | Electrical installations for lighting and beaconing of aerodromes - Safety secondary circuits in series circuits - General safety requirements |
EN 55024 : 2010 AMD 1 2015 | INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 24:2010/A1:2015) |
EN 62343-2:2014 | Dynamic modules - Part 2: Reliability qualification |
EN 50090-2-2:1996/A2:2007 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-2: SYSTEM OVERVIEW - GENERAL TECHNICAL REQUIREMENTS |
EN 55016-1-2:2014/A1:2018 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-2: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - COUPLING DEVICES FOR CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-1-2:2014/A1:2017) |
EN 62041:2010 | Safety of transformers, reactors, power supply units and combinations thereof - EMC requirements |
EN 50370-1:2005 | Electromagnetic compatibility (EMC) - Product family standard for machine tools - Part 1: Emission |
EN 62052-21:2004/A1:2017/AC:2018-04 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 21: TARIFF AND LOAD CONTROL EQUIPMENT (IEC 62052-21:2004/A1:2016/COR1:2018) |
EN 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
EN 62052-11:2003/A1:2017/AC:2018-04 | ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 11: METERING EQUIPMENT (IEC 62052-11:2003/A1:2016/COR1:2018) |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
EN 50498:2010 | Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles |
EN 60834-1:1999 | Teleprotection equipment of power systems - Performance and testing - Part 1: Command systems |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
EN 61672-2:2013/A1:2017 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS (IEC 61672-2:2013/A1:2017) |
EN 60804:2000 | Integrating-averaging sound level meters |
EN 60268-4:2014 | Sound system equipment - Part 4: Microphones |
EN 62040-2:2006/corrigendum:2006 | |
EN 50491-5-1:2010 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 5-1: EMC requirements, conditions and test set-up |
EN 50529-2:2010 | EMC Network Standard - Part 2: Wire-line telecommunications networks using coaxial cables |
EN 50463:2007 | Railway applications - Energy measurement on board trains |
EN 50529-1:2010 | EMC NETWORK STANDARD - PART 1: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING TELEPHONE WIRES |
EN 60255-26:2013/AC:2013 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS |
EN 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
EN 55103-1:2009/A1:2012 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS |
CSA IEC 61000-6-2 : 2008 : R2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS |
CSA IEC 61000-6-2 : 2008 : R2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS |
CSA IEC 61000-6-2 : 2008 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS |
UNE-EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
AS IEC 62040.2:2019 | Uninterruptible power systems (UPS) Electromagnetic compatibility (EMC) requirements |
CISPR 13:2009+AMD1:2015 CSV | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
AS IEC 61260.2:2019 | Electroacoustics - Octave-band and fractional-octave-band filters Pattern evaluation tests |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
AS IEC 61260.1:2019 | Electroacoustics - Octave-band and fractional-octave-band filters Specifications |
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.