• There are no items in your cart

CEN/TR 1046:2013

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Thermoplastics piping and ducting systems - Systems outside building structures for the conveyance of water or sewage - Practices for underground installation

Withdrawn date

03-11-2023

Superseded by

CEN/TS 1046:2021

Published date

12-18-2013

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Transport, handling and storage at depots
  and sites
6 Installation
7 Methods of assembly (jointing)
8 Bends
9 Inspection and testing
Annex A (normative) - Classification of soils
Annex B (informative) - Behaviour of buried
        flexible pipes
Annex C (normative) - Joint and jointing examples
Bibliography

This Technical Report is applicable to the installation of thermoplastics piping systems to be used for the conveyance of water or sewage under gravity and pressure conditions underground. It is intended to be used for pipes of nominal size up to and including DN 1600.Wherever the term "pipe" is used in this Technical Report, it also serves to cover any "fittings", "ancillary" products and "components" if not otherwise specified.NOTE 1This document does not apply to pipelines for gas supply (see EN 12007-2, Gas supply systems pipelines for maximum operating pressure up to and including 16 bars - Part 2: Specific functional recommendations for PE- and MOP up to and including 10 bars).NOTE 2It is assumed that additional recommendations and/or requirements are detailed in the individual materials voluntary product standards. Instances where this is expected to apply include those indicated in this Technical Report as follows:a)any special transportation requirements (see 5.2);b)maximum storage height (see 5.2 and 5.4);c)maximum storage period in direct sunlight (see 5.4);d)any climatic conditions requiring special storage (see 5.4);e)limiting initial and/or long-term deflections (see 6.1.1 and 6.1.2);f)information on mole ploughing and boring (see and 6.2), if applicable;g)selection of appropriate jointing system (see Clause 7);h)recommended radii of curvature for cold bending (see 8.1);i)permitted rates of loss of water under test (see 9.2.1);j)if applicable the relationship between SDR and stiffness.Requirements and instructions concerning commissioning of systems can be found in EN 805 and EN 1610 and the relevant national and/or local regulations.

Committee
CEN/TC 155
DevelopmentNote
Supersedes ENV 1046, ENV 1401-3, CEN/TS 1852-3 and CEN/TS 14758-3. (01/2014) Supersedes NS ENV 1046. (02/2014) Supersedes NBN ENV 1046, NBN ENV 1401-3 & NBN CEN/TS 1852-3. (04/2014) Supersedes UNE ENV 1401-3, UNE CEN/TS 14758-3, UNE CEN/TS 1852-3 & UNE ENV 1046. (12/2014)
DocumentType
Technical Report
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
S.R. CEN/TR 1046:2013 Identical
NEN NPR CEN/TR 1046 : 2014 Identical
UNE-CEN/TR 1046:2013 Identical

16/30336859 DC : 0 BS EN 1852-1 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - POLYPROPYLENE (PP) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
I.S. EN 1852-1:2018 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - POLYPROPYLENE (PP) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
S.R. CEN/TS 15223:2017 PLASTICS PIPING SYSTEMS - VALIDATED DESIGN PARAMETERS OF BURIED THERMOPLASTICS PIPING SYSTEMS
PREN 1852-1 : DRAFT 2016 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - POLYPROPYLENE (PP) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEM
EN 1852-1:2018 Plastics piping systems for non-pressure underground drainage and sewerage - Polypropylene (PP) - Part 1: Specifications for pipes, fittings and the system
ISO/TR 4191:2014 Plastics piping systems for water supply Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O) Guidance for installation
BS EN 1852-1:2018 Plastics piping systems for non-pressure underground drainage and sewerage. Polypropylene (PP) Specifications for pipes, fittings and the system
PD ISO/TR 4191:2014 Plastics piping systems for water supply. Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O). Guidance for installation
CEN/TS 15223:2017 Plastics piping systems - Validated design parameters of buried thermoplastics piping systems

EN 1295-1:1997 Structural design of buried pipelines under various conditions of loading - Part 1: General requirements
ISO/TS 10465-1:2007 Underground installation of flexible glass-reinforced pipes based on unsaturated polyester resin (GRP-UP) — Part 1: Installation procedures
EN 13508-1:2012 Investigation and assessment of drain and sewer systems outside buildings - Part 1: General Requirements
ISO/TR 10465-2:2007 Underground installation of flexible glass-reinforced pipes based on unsaturated polyester resin (GRP-UP) Part 2: Comparison of static calculation methods
EN 805:2000 Water supply - Requirements for systems and components outside buildings
ISO/TR 10465-3:2007 Underground installation of flexible glass-reinforced pipes based on unsaturated polyester resin (GRP-UP) Part 3: Installation parameters and application limits
ISO 21307:2011 Plastics pipes and fittings Butt fusion jointing procedures for polyethylene (PE) pipes and fittings used in the construction of gas and water distribution systems
CEN/TS 15223:2017 Plastics piping systems - Validated design parameters of buried thermoplastics piping systems
EN 476:2011 General requirements for components used in drains and sewers
EN 14758-1:2012 Plastics piping systems for non-pressure underground drainage and sewerage - Polypropylene with mineral modifiers (PP-MD) - Part 1: Specifications for pipes, fittings and the system
EN 12666-1:2005+A1:2011 Plastics piping systems for non-pressure underground drainage and sewerage - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system
EN 1401-1:2009 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
EN 1610:2015 Construction and testing of drains and sewers
EN 13508-2:2003+A1:2011 Investigation and assessment of drain and sewer systems outside buildings - Part 2: Visual inspection coding system

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.