• Shopping Cart
    There are no items in your cart

CEI EN 60099-9 : 2015

Current

Current

The latest, up-to-date edition.

SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2015

US$404.40
Excluding Tax where applicable

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Typical HVDC converter station schemes, arrester
   types, locations and operating voltage
5 Identification and classification
6 Service conditions
7 Requirements
8 General testing procedure
9 Type tests (design tests)
10 Routine tests and acceptance test
11 Test requirements on different types of arresters
Annex A (normative) - Test to verify thermal equivalency
        between complete arrester and arrester section
Annex B (normative) - Determination of the start temperature
        in the thermal recovery test
Annex C (normative) - Mechanical considerations
Annex D (informative) - Different circuit configurations
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding
         European publications

Pertains to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1100 kV.

Committee
CT 37
DevelopmentNote
Classificazione CEI 37-18. (03/2015)
DocumentType
Standard
Pages
96
PublisherName
Comitato Elettrotecnico Italiano
Status
Current

Standards Relationship
IEC 60099-9:2014 Identical
EN 60099-9:2014 Identical

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
ISO 4892-1:2016 Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance
IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60143-1:2015 Series capacitors for power systems - Part 1: General
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
IEC TS 60071-5:2002 Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC) converter stations
EN 60060-2:2011 High-voltage test techniques - Part 2: Measuring systems
EN 60143-2:2013 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
ISO 4892-3:2016 Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps
EN 60068-2-17:1994 Environmental testing - Part 2: Tests - Test Q: Sealing
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
CISPR TR 18-2:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
IEC 60633:1998+AMD1:2009+AMD2:2015 CSV Terminology for high-voltage direct current (HVDC) transmission
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
ISO 4892-2:2013 Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps
EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
EN 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)