1. GENERAL
2. REPRESENTATIVE VOLTAGE STRESSES
   IN SERVICE
3. CO-ORDINATION WITHSTAND VOLTAGE
4. REQUIRED WITHSTAND VOLTAGE
5. STANDARD WITHSTAND VOLTAGE AND
   TESTING PROCEDURES
6. SPECIAL CONSIDERATIONS FOR OVERHEAD LINES
7. SPECIAL CONSIDERATIONS FOR SUBSTATIONS
ANNEX A - CLEARANCES IN AIR TO
          ASSURE A SPECIFIED IMPULSE
          WITHSTAND VOLTAGE
          INSTALLATION
ANNEX B - DETERMINATION OF
          TEMPORARY OVERVOLTAGES
          DUE TO EARTH FAULTS
ANNEX C - WEIBULL PROBABILITY
          DISTRIBUTIONS
ANNEX D - DETERMINATION OF THE
          REPRESENTATIVE SLOW-FRONT
          OVERVOLTAGE DUE TO LINE
          ENERGIZATION AND RE-ENERGIZATION
ANNEX E - TRANSFERRED OVERVOLTAGES
          IN TRANSFORMERS
ANNEX F - LIGHTNING OVERVOLTAGES
ANNEX G - CALCULATION OF AIR GAP
          BREAKDOWN STRENGTH FROM
          EXPERIMENTAL DATA
ANNEX H - EXAMPLES OF INSULATION
          CO-ORDINATION PROCEDURE
ANNEX J - BIBLIOGRAPHY
ANNEX ZA - Normative references to
           International publications with
           their corresponding European
           publications

Defines the constitutes an application guide and deals with the selection of insulation levels of equipment or installations for three-phase electrical systems.

Committee
CT 28
DevelopmentNote
Classificazione CEI 28-4 (08/2001) Supersedes CEI 28-3 (03/2004)
DocumentType
Standard
Pages
162
PublisherName
Comitato Elettrotecnico Italiano
Status
Current
SupersededBy
Supersedes

Standards Relationship
EN 60071-2:1997 Identical
IEC 60071-2:1996 Identical

HD 478.2.3 : 200S1 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - AIR PRESSURE
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
CEI 75-5 : 1997 CLASSIFICAZIONE DELLE CONDIZIONI AMBIENTALI - PARTE 2: CONDIZIONI AMBIENTALI PRESENTI IN NATURA PRESSIONE ATMOSFERICA
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 60056:1987 High-voltage alternating-current circuit-breakers
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
EN 60099-1:1994/A1:1999 SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS
CEI 17-1 : 5ED 1998
IEC 60505:2011 Evaluation and qualification of electrical insulation systems
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
IEC 60099-1:1991+AMD1:1999 CSV Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems
HD 348 : 200S7 HIGH-VOLTAGE ALTERNATING-CURRENT CIRCUIT-BREAKERS
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
CEI 42-4 : 1997 TECNICHE DI PROVA AD ALTA TENSIONE - PARTE 1: DEFINIZIONI E PRESCRIZIONI GENERALI RELATIVE ALLE PROVE
IEC 60721-2-3:2013 Classification of environmental conditions - Part 2-3: Environmental conditions appearing in nature - Air pressure

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.