CEI CLC/TS 50625-3-3 : 1ED 2018
Current
The latest, up-to-date edition.
COLLECTION, LOGISTICS & TREATMENT REQUIREMENTS FOR WEEE - PART 3-3: SPECIFICATION FOR DE-POLLUTION - WEEE CONTAINING CRTS AND FLAT PANEL DISPLAY
03-28-2018
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 De-pollution monitoring
5 Overview of the applicable methodologies - Applicable
methodologies
6 Large appliances
7 Cooling and freezing appliances
8 CRT Display / FPD appliances
9 Lamps - introduction and analysis methodology
10 Small appliances
Annex A (normative) - Sampling protocol for the physically
smallest non-metallic mechanical treatment fraction
Annex B (normative) - Sampling protocol for plastics
Annex C (normative) - Targets
Annex D (informative) - Target calculation example -
Calculation example for large appliance
Annex AA (normative) - CRT and FPD: Sampling protocol
Annex BB (normative) - CRT: Analysis protocol for residual
CRT glass in CRT fractions
Annex CC (normative) - CRT: Analysis protocol for
fluorescent coating remaining on cleaned CRT glass
Annex DD (normative) - CRT: Analysis protocol for the lead
oxide in separated panel glass
Annex EE (normative) - FPD: Main steps for Mass Balance
Annex FF (normative) - FPD: Analysis of the de-polluted
physically smallest shredded mix fraction of flat
panel displays
Annex GG (informative) CRT: Background on analysis
protocol for fluorescent coating remaining on
cleaned CRT glass
Bibliography
Pertains to be used in conjunction with Collection, logistics and treatment requirements for WEEE - Part 1: General treatment requirements, EN 50625-1, Collection, logistics and Treatment requirements for WEEE - Part 2-2: Treatment requirements for WEEE containing CRTs and flat panel displays, EN 50625-2-2 and Collection, logistics and treatment requirements for WEEE - Part 3-1: Specification for de-pollution - General, CLC/TS 50625-3-1.
Committee |
CT 111
|
DevelopmentNote |
Classificazione CEI 111-79. (02/2018)
|
DocumentType |
Standard
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Current
|
Standards | Relationship |
CLC/TS 50625-3-3:2017 | Identical |
CLC/TS 50625-3-1:2015 | Collection, logistics & treatment requirements for WEEE - Part 3-1: Specification for de-pollution - General |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 50625-1:2014 | Collection, logistics & Treatment requirements for WEEE - Part 1: General treatment requirements |
EN ISO 12846:2012 | Water quality - Determination of mercury - Method using atomic absorption spectrometry (AAS) with and without enrichment (ISO 12846:2012) |
ISO 17852:2006 | Water quality Determination of mercury Method using atomic fluorescence spectrometry |
ISO 12846:2012 | Water quality — Determination of mercury — Method using atomic absorption spectrometry (AAS) with and without enrichment |
ISO 11885:2007 | Water quality Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) |
ISO 16772:2004 | Soil quality — Determination of mercury in aqua regia soil extracts with cold-vapour atomic spectrometry or cold-vapour atomic fluorescence spectrometry |
EN 15309:2007 | Characterization of waste and soil - Determination of elemental composition by X-ray fluorescence |
EN 15002:2015 | Characterization of waste - Preparation of test portions from the laboratory sample |
EN 13656:2002 | Characterization of waste - Microwave assisted digestion with hydrofluoric (HF), nitric (HNO3) and hydrochloric (HCl) acid mixture for subsequent determination of elements |
EN 13657:2002 | Characterization of waste - Digestion for subsequent determination of aqua regia soluble portion of elements |
EN 14899:2005 | Characterization of waste - Sampling of waste materials - Framework for the preparation and application of a Sampling Plan |
ISO 17294-2:2016 | Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of selected elements including uranium isotopes |
EN ISO 17294-2:2016 | Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes (ISO 17294-2:2016) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.