C22.2 NO. 38-18
Current
The latest, up-to-date edition.
THERMOSET-INSULATED WIRES AND CABLES
Hardcopy , PDF
English
01-01-2018
PREFACE
1 Scope
2 General
3 Definitions
4 Construction
5 Test Requirements
6 Marking
7 Deep-Well Submersible Water-Pump Cable
Annex A (informative) - Conductor types covered by
this Standard
Annex B (informative) - Summary of requirements
Annex C (normative) - Chemical composition of aluminum
conductors
Annex D (normative) - Copper-clad aluminum conductors
Annex E (informative) - Metric sizes
Annex F (informative) - Rope-lay stranded flexible conductors
Annex G (normative) - Protective coverings other than jackets
Annex H (normative for Canada) - Color identification of
circuit conductors
Annex I (normative) - Formulas for calculating insulation
resistance of types having parameters other than
as specified in this Standard
Annex J (normative) - Alternative national markings
Annex K (normative) - Requirements for Types RW75, R90,
and RW90 rated 5000 V
Preface This is the harmonized ANCE, CSA Group, and UL standard for Thermoset-Insulated Wires and Cable s. It is the Sixth edition of NMX-J-451-ANCE, the Eleventh edition of CSA C22.2 No. 38, and the Nineteenth edition of UL 44. This edition of NMX-J-451-ANCE supersedes the previous edition published in March 28, 2014. This edition of CSA C22.2 No. 38 supersedes the previous edition published in March 28, 2014. This edition of UL 44 supersedes the previous edition published in March 28, 2014. This harmonized standard has been jointly revised on May 14, 2021. For this purpose, CSA Group and UL are issuing revision pages dated May 14, 2021, and ANCE is issuing a new edition dated May 14, 2021. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the requirements for single-conductor and multiple-conductor thermoset-insulated wires and cables rated 600 V, 1000 V, 2000 V, and 5000 V, for use in accordance with the rules of the Canadian Electrical Code, Part I, CSA C22.1, in Canada, Standard for Electrical Installations, NOM-001-SEDE, in Mexico, and the National Electrical Code (NEC), NFPA 70, in the United States of America. See Annex A for the complete list of types and voltage ratings covered by this Standard and the specific electrical codes for which they are intended, and Annex B for a summary of construction and test requirements for these types. 1.2 Table 1 provides a summary of the maximum conductor temperature, voltage ratings, and the number of insulated conductors for the types to which this Standard applies. 1.3 This Standard also specifies the requirements for submersible pump cables, with or without jackets, in Deep Well Submersible Water-Pump Cable, Section 7. No type-letter designations are assigned to these cables. 1.4 Products within this Standard might have applications not covered by the electrical codes listed in 1.1.
DevelopmentNote |
Also numbered as UL 44 and ANCE NMX-J-451. (08/2005)
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0489-7
|
Pages |
0
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the harmonized ANCE, CSA Group, and UL standard for Thermoset-Insulated Wires and Cable s. It is the Sixth edition of NMX-J-451-ANCE, the Eleventh edition of CSA C22.2 No. 38, and the Nineteenth edition of UL 44. This edition of NMX-J-451-ANCE supersedes the previous edition published in March 28, 2014. This edition of CSA C22.2 No. 38 supersedes the previous edition published in March 28, 2014. This edition of UL 44 supersedes the previous edition published in March 28, 2014. This harmonized standard has been jointly revised on May 14, 2021. For this purpose, CSA Group and UL are issuing revision pages dated May 14, 2021, and ANCE is issuing a new edition dated May 14, 2021. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the requirements for single-conductor and multiple-conductor thermoset-insulated wires and cables rated 600 V, 1000 V, 2000 V, and 5000 V, for use in accordance with the rules of the Canadian Electrical Code, Part I, CSA C22.1, in Canada, Standard for Electrical Installations, NOM-001-SEDE, in Mexico, and the National Electrical Code (NEC), NFPA 70, in the United States of America. See Annex A for the complete list of types and voltage ratings covered by this Standard and the specific electrical codes for which they are intended, and Annex B for a summary of construction and test requirements for these types. 1.2 Table 1 provides a summary of the maximum conductor temperature, voltage ratings, and the number of insulated conductors for the types to which this Standard applies. 1.3 This Standard also specifies the requirements for submersible pump cables, with or without jackets, in Deep Well Submersible Water-Pump Cable, Section 7. No type-letter designations are assigned to these cables. 1.4 Products within this Standard might have applications not covered by the electrical codes listed in 1.1.
IEC 60228:2004 | Conductors of insulated cables |
CSA C22.2 No. 96 : 2013 | PORTABLE POWER CABLES |
ASTM B 172 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors |
UL 1309:3ED 2017-04-21 | Marine Shipboard Cable |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
CSA C22.2 No. 2556 : 2015 | WIRE AND CABLE TEST METHODS |
ASTM B 173 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors |
ASTM B 835 : 2014 : REDLINE | Standard Specification for Compact Round Stranded Copper Conductors Using Single Input Wire Construction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.