• Shopping Cart
    There are no items in your cart

BS ISO/TR 13387-7:1999

Current

Current

The latest, up-to-date edition.

Fire safety engineering Detection, activation and suppression

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

02-15-2000

US$302.14
Excluding Tax where applicable

1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
      4.1 Symbols
      4.2 Abbreviated terms
5 Subsystem 4 of the total design system
      5.1 General discussion
      5.2 Explanation and illustrations
      5.3 Information flow
6 Subsystem evaluations
      6.1 Detection time
      6.2 Activation time
      6.3 Performance of suppression systems
7 Engineering methods
      7.1 General applications to subsystem 4
      7.2 Estimation formulae
      7.3 Computer models
      7.4 Experimental methods
      7.5 Reliability analysis
Annex A (informative) Physical mechanisms of suppression by
                      water sprays
Annex B (informative) Calculation of response time for fixed
                      temperature detectors
Annex C (informative) Extinguishment by chemical and powder
                      aerosols
Bibliography

Intended to provide guidance to regulators, designers and fire- safety professionals on the fundamental engineering methods that should be included in design guides and reference manuals to predict: a) the effectiveness of activated automatic suppression systems in limiting the potential consequences of a fire, based on key system characteristics; b) times to detect fire events, based on the design-fire environment and properties and/or location of automatic detection devices; c) times to activate automatic alarm systems and automatic systems designed to control fire growth or to control the effects of fire, based on system design parameters.

Committee
FSH/24
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Current

This part of ISO13387 is intended to provide guidance to designers, regulators and fire-safety professionals on the fundamental engineering methods that should be included in design guides and reference manuals for the prediction of: times to detect fire events, based on the design-fire environment and properties and/or location of automatic detection devices; times to activate automatic alarm systems and automatic systems designed to control fire growth or to control the effects of fire, based on system design parameters; the effectiveness of activated automatic suppression systems in limiting the potential consequences of a fire, based on key system characteristics. NOTE The effect of human intervention on detection, activation or suppression is considered beyond the scope of this document. This part of ISO13387 is not itself a design guide or reference manual but can be used as a resource by national organizations in the preparation of such documents. This report also provides a framework for critically reviewing the suitability of engineering methods, whether hand calculations or predictive computer models or correlations based on empirical data, to predict detection, activation and the effect of fire suppression systems. Note that the term \'engineering method\' used in this document refers to any of the preceding techniques.

Standards Relationship
ISO/TR 13387-7:1999 Identical

PD 7974-1:2003 Application of fire safety engineering principles to the design of buildings Initiation and development of fire within the enclosure of origin (Sub-system 1)

NFPA 2001 : 2015 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS
NFPA 750 : 2015 WATER MIST FIRE PROTECTION SYSTEMS
EN 54-9:1982/AC1:1985 COMPONENTS OF AUTOMATIC FIRE DETECTION SYSTEMS - FIRE SENSITIVITY TEST
ISO/TR 13387-1:1999 FIRE SAFETY ENGINEERING - PART 1: APPLICATION OF FIRE PERFORMANCE CONCEPTS TO DESIGN OBJECTIVES
ISO 6182-1:2014 Fire protection Automatic sprinkler systems Part 1: Requirements and test methods for sprinklers
ISO/TR 13387-3:1999 Fire safety engineering Part 3: Assessment and verification of mathematical fire models
NFPA 17A : 2017 WET CHEMICAL EXTINGUISHING SYSTEMS
ISO/TR 13387-8:1999 FIRE SAFETY ENGINEERING - PART 8: LIFE SAFETY - OCCUPANT BEHAVIOUR, LOCATION AND CONDITION
NFPA 92B : 2009 SMOKE MANAGEMENT SYSTEMS IN MALLS, ATRIA, AND LARGE SPACES
NFPA 11 : 2016 LOW-, MEDIUM-, AND HIGH-EXPANSION FOAM
ISO/TR 13387-4:1999 Fire safety engineering — Part 4: Initiation and development of fire and generation of fire effluents
NFPA 12 : 2015 CARBON DIOXIDE EXTINGUISHING SYSTEMS
ISO/TR 13387-2:1999 Fire safety engineering Part 2: Design fire scenarios and design fires
ISO 3009:2003 Fire-resistance tests — Elements of building construction — Glazed elements
NFPA 72 : 2016 NATIONAL FIRE ALARM AND SIGNALING CODE
NFPA 13 : 2016 INSTALLATION OF SPRINKLER SYSTEMS
ISO/TR 13387-6:1999 Fire safety engineering Part 6: Structural response and fire spread beyond the enclosure of origin
NFPA 16 : 2015 INSTALLATION OF FOAM-WATER SPRINKLER AND FOAM-WATER SPRAY SYSTEMS
ISO/TR 13387-5:1999 Fire safety engineering Part 5: Movement of fire effluents
NFPA 11A : 1999 MEDIUM- AND HIGH-EXPANSION FOAM SYSTEMS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.