BS ISO/IEC 10192-3:2017
Current
The latest, up-to-date edition.
Information technology. Home electronic system (HES) interfaces Modular communications interface for energy management
Hardcopy , PDF
English
01-05-2018
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 Conformance
5 Physical/electrical Interface
6 Serial protocol
7 Simple Protocol
8 Link layer
9 Data-link messages
10 Basic DR application (Message Type = 0x08, 0x01)
11 Intermediate DR application (Message
Type = 0x08, 0x02)
12 Commissioning and network messages (Message
Type = 0x08, 0x04)
13 Pass-Through Mode
14 Typical communication exchanges
15 General security principles
16 Load management event randomization
Annex A (normative) - Low voltage DC form factor
Annex B (informative) - Description of DC form factor applications
Annex C (normative) - AC form factor
Annex D (normative) - Fletcher checksum
Annex E (informative) - Example Visual Basic code
Annex F (informative) - Guideline for computing average price
Annex G (informative) - Product safety considerations
Bibliography
Describes a UCM (Universal Communications Module) that transfers energy management data via a home network between an end-device and an energy management agent (specified in ISO/IEC 15067-3) or an energy service provider.
Committee |
IST/6/-/12
|
DevelopmentNote |
Supersedes 17/30326999 DC. (01/2018)
|
DocumentType |
Standard
|
Pages |
100
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This part of IEC10192 specifies a UCM (Universal Communications Module) that transfers energy management data via a home network between an end-device and an energy management agent (specified in ISO/IEC15067‑3) or an energy service provider. This document specifies the mechanical, electrical and logical characteristics of the interfaces of UCM to an end-device (hereafter referred to as an SGD— Smart Grid Device) and a choice of interfaces to a home communications network.
This document specifies the physical and data-link characteristics of the interface between the UCM and the SGD, along with certain higher-layer and application layer elements as needed to assure interoperability over a broad range of device capabilities. It specifies a mechanism through which network, transport and application layer messages specified in other documents listed in this document may be passed through the interface. For those end-devices that cannot process one of the “pass-through” command sets, a Simple Protocol is specified according to the OSI (Open System Interconnect) reference model (ISO/IEC7498‑1) including application layer messaging for energy management.
The UCM specified in this document is intended to be installable by the purchaser, home occupant or professional installer. The connectors are integrated in a way that allows for easy, plug-in installation. However, the manufacturer may choose to pre-install a module during production or have installation handled by a manufacturer representative or professional installer.
The scope of this document does not include safety related construction, performance, marking or instruction requirements. UCM products should additionally comply with applicable product safety standard(s). Examples of such standards are presented in AnnexG.
NOTE Some regulatory authorities require that appliances intended for participation in energy management, such as thermostats, be user installable.
Standards | Relationship |
ISO/IEC 10192-3:2017 | Identical |
ISO/IEC 14543-4-3:2015 | Information technology Home Electronic Systems (HES) architecture Part 4-3: Application layer interface to lower communications layers for network enhanced control devices of HES Class 1 |
ISO/IEC 7498-1:1994 | Information technology Open Systems Interconnection Basic Reference Model: The Basic Model |
ISO/IEC 15067-3:2012 | Information technology — Home Electronic System (HES) application model — Part 3: Model of a demand-response energy management system for HES |
ISO/IEC 14543-3-1:2006 | Information technology Home electronic systems (HES) architecture Part 3-1: Communication layers Application layer for network based control of HES Class 1 |
SAE J 1772 : 2016 | SAE ELECTRIC VEHICLE AND PLUG IN HYBRID ELECTRIC VEHICLE CONDUCTIVE CHARGE COUPLER |
ISO/IEC 14908-1:2012 | Information technology — Control network protocol — Part 1: Protocol stack |
ISO 4217:2015 | Codes for the representation of currencies |
ISO/IEC 24739-3:2010 | Information technology AT Attachment with Packet Interface - 7 Part 3: Serial transport protocols and physical interconnect (ATA/ATAPI-7 V3) |
IEC PAS 62746-10-1:2014 | Systems interface between customer energy management system and the power management system - Part 10-1: Open Automated Demand Response (OpenADR 2.0b Profile Specification) |
ISO/IEC 8482:1993 | Information technology Telecommunications and information exchange between systems Twisted pair multipoint interconnections |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.