BS ISO 2425:2010
Current
The latest, up-to-date edition.
Hydrometry. Measurement of liquid flow in open channels under tidal conditions
Hardcopy , PDF
English
12-31-2010
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Principles of methods of measurement
6 Special considerations and choice of method
7 Measurement of tidal flow
8 Uncertainties in tidal flow measurement
Annex A (informative) - Measurement of tidal flow by
cubature method
Annex B (informative) - Measurement methods suitable for
tidal flow conditions
Annex C (informative) - Record of velocity measurement of
a tidal river
Annex D (informative) - Measurement of tidal flow using
an acoustic Doppler velocity meter
Bibliography
Specifies a summary of recommended methods for the determination of liquid flow in tidal channels, special consideration being given to those techniques that are either unique to or particularly appropriate for application under tidal conditions, including treatment of uncertainties.
Committee |
CPI/113
|
DevelopmentNote |
Issue Date: 30/06/2008. Supersedes BS 3680-6(1995). (06/2008) Supersedes 09/30169001 DC. (12/2010)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard provides a summary of recommended methods for the determination of liquid flow in tidal channels, special consideration being given to those techniques that are either unique to or particularly appropriate for application under tidal conditions, including treatment of uncertainties. Reference is also made, where appropriate, to methods for the determination of flow in non-tidal channels, but attention is drawn to their limitations with respect to practicality and/or uncertainty. This International Standard does not describe alternative methods, such as the use of weirs, flumes, dilution gauging, salt velocity and floats, although they might be suitable under certain conditions, especially where the effect of tides only impedes and does not stop or reverse the passage of stream flow. These methods are described in detail in other International Standards. This International Standard specifies two types of technique: techniques for single measurements of tidal flow; techniques for continuous measurement of tidal flow. AnnexA specifies the cubature method of measurement. AnnexB specifies methods for the determination of flow under tidal conditions, and AnnexC gives an example of the computation for a single vertical. Similar computations are possible for other verticals. AnnexD describes the determination of tidal flow using an acoustic Doppler velocity meter.
Standards | Relationship |
ISO 2425:2010 | Identical |
ISO 748:2007 | Hydrometry Measurement of liquid flow in open channels using current-meters or floats |
ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
ISO 6416:2017 | Hydrometry — Measurement of discharge by the ultrasonic transit time (time of flight) method |
ISO 1100-2:2010 | Hydrometry Measurement of liquid flow in open channels Part 2: Determination of the stage-discharge relationship |
ISO 4373:2008 | Hydrometry Water level measuring devices |
ISO 3454:2008 | Hydrometry — Direct depth sounding and suspension equipment |
ISO/TR 9823:1990 | Liquid flow measurement in open channels Velocity-area method using a restricted number of verticals |
ISO 4369:1979 | Measurement of liquid flow in open channels Moving-boat method |
ISO/TR 7178:1983 | Liquid flow measurement in open channels Velocity-area methods Investigation of total error |
ISO 4366:2007 | Hydrometry — Echo sounders for water depth measurements |
ISO 9123:2017 | Hydrometry — Stage-fall-discharge relationships |
ISO 1088:2007 | Hydrometry Velocity-area methods using current-meters Collection and processing of data for determination of uncertainties in flow measurement |
ISO 15769:2010 | Hydrometry Guidelines for the application of acoustic velocity meters using the Doppler and echo correlation methods |
ISO/TR 9209:1989 | Measurement of liquid flow in open channels Determination of the wetline correction |
ISO 9825:2005 | Hydrometry Field measurement of discharge in large rivers and rivers in flood |
ISO 1100-1:1996 | Measurement of liquid flow in open channels Part 1: Establishment and operation of a gauging station |
ISO 9213:2004 | Measurement of total discharge in open channels Electromagnetic method using a full-channel-width coil |
ISO 4375:2014 | Hydrometry Cableway systems for stream gauging |
ISO/TR 8363:1997 | Measurement of liquid flow in open channels General guidelines for selection of method |
ISO 772:1996 | Hydrometric determinations — Vocabulary and symbols |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.