Smoke and heat control systems Specification for control equipment
Hardcopy , PDF
English
10-31-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 General
5 Electrical systems
6 Pneumatic systems
7 Mechanical control panels (m.c.p.)
8 Design and documentation requirements
9 Additional requirements for software-controlled
control panels
10 Additional requirements for networked systems
11 Marking
12 General test requirements
13 Tests
14 Conformity assessment
Annex A (normative) - Explanation of access levels
Annex B (informative) - Summary of functions
Bibliography
Defines the product performance requirements, classifications and test methods for control equipment designed for use in smoke- and heat-control systems (SHCS) in buildings.
Committee |
FSH/25
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
British Standards Institution
|
Status |
Current
|
SupersededBy |
This part of ISO21927 specifies the product performance requirements, classifications and test methods for control equipment designed for use in smoke- and heat-control systems (SHCS) in buildings.
Standards | Relationship |
ISO 21927-9:2012 | Identical |
BS 8524-1:2013 | Active fire curtain barrier assemblies Specification |
BS 7346-8:2013 | Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
ISO 7240-10:2012 | Fire detection and alarm systems — Part 10: Point-type flame detectors |
ISO/IEC 17000:2004 | Conformity assessment Vocabulary and general principles |
ISO 7240-15:2014 | Fire detection and alarm systems — Part 15: Point-type fire detectors using smoke and heat sensors |
ISO/IEC 17050-1:2004 | Conformity assessment Supplier's declaration of conformity Part 1: General requirements |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
ISO 7240-12:2014 | Fire detection and alarm systems Part 12: Line type smoke detectors using a transmitted optical beam |
ISO 7240-2:2003 | Fire detection and alarm systems Part 2: Control and indicating equipment |
ISO 21927-10:2011 | Smoke and heat control systems — Part 10: Specification for power output devices |
ISO 7240-27:2009 | Fire detection and alarm systems Part 27: Point-type fire detectors using a scattered-light, transmitted-light or ionization smoke sensor, an electrochemical-cell carbon-monoxide sensor and a heat sensor |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO 7240-6:2011 | Fire detection and alarm systems — Part 6: Carbon monoxide fire detectors using electro-chemical cells |
ISO/IEC 17050-2:2004 | Conformity assessment Supplier's declaration of conformity Part 2: Supporting documentation |
ISO 7240-11:2011 | Fire detection and alarm systems Part 11: Manual call points |
ISO 3098-2:2000 | Technical product documentation — Lettering — Part 2: Latin alphabet, numerals and marks |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 7240-5:2012 | Fire detection and alarm systems Part 5: Point-type heat detectors |
ISO 21927-3:2006 | Smoke and heat control systems Part 3: Specification for powered smoke and heat exhaust ventilators |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 7240-8:2014 | Fire detection and alarm systems Part 8: Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
ISO 7240-7:2011 | Fire detection and alarm systems Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization |
ISO 7240-20:2010 | Fire detection and alarm systems Part 20: Aspirating smoke detectors |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.