BS ISO 21438-1:2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Workplace atmospheres. Determination of inorganic acids by ion chromatography Part 1: Non-volatile acids (sulfuric acid and phosphoric acid)
Hardcopy , PDF
09-01-2022
English
01-31-2008
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
3.1 General definitions
3.2 Particle size fraction definitions
3.3 Sampling definitions
3.4 Analytical definitions
3.5 Statistical terms
4 Principle
5 Requirement
6 Reagents
7 Apparatus
7.1 Sampling equipment
7.2 Laboratory apparatus
8 Occupational exposure assessment
8.1 General
8.2 Personal sampling
8.3 Static sampling
8.4 Selection of measurement conditions and
measurement pattern
9 Sampling
9.1 Preliminary considerations
9.2 Preparation for sampling
9.3 Sampling position
9.4 Collection of samples
9.5 Transportation
10 Analysis
10.1 Preparation of test and calibration solutions
10.2 Instrumental analysis
10.3 Estimation of detection and quantification
limits
10.4 Quality control
10.5 Measurement uncertainty
11 Expression of results
12 Method performance
12.1 Sample collection and stability
12.2 Quantification limits
12.3 Upper limits of the analytical range
12.4 Bias and precision
12.5 Uncertainty of sampling and analysis method
12.6 Interferences
13 Test report
13.1 Test record
13.2 Laboratory report
Annex A (informative) Temperature and pressure correction
Bibliography
Describes a method for the determination of the time-weighted average mass concentration of sulfuric acid and phosphoric acid in workplace air by ion chromatography.
Committee |
EH/2/2
|
DevelopmentNote |
Supersedes 06/30127422 DC. (01/2008)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of ISO21438 specifies a method for the determination of the time-weighted average mass concentration of sulfuric acid and phosphoric acid in workplace air by ion chromatography.
The method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO7708 and to static (area) sampling.
The analytical method is applicable to the determination of masses of 0,005mg to 2,0mg of sulfuric acid and phosphoric acid per sample, without dilution.
The concentration range of sulfuric acid and phosphoric acid in air for which the measuring procedure is applicable is determined by the sampling method selected by the user. For an air sample of volume1m3, the working range is approximately 0,005mg m−3 to 2,0mg m−3.
The method is not applicable to the determination of sulfur trioxide.
The procedure does not allow differentiation between the acids and their corresponding salts if both are present in the air.
The procedure does not allow differentiation between phosphoric acid and diphosphorus pentoxide (phosphoric anhydride) if both are present in the workplace.
Standards | Relationship |
ISO 21438-1:2007 | Identical |
ASTM E 1370 : 2014 : REDLINE | Standard Guide for Air Sampling Strategies for Worker and Workplace Protection |
EN 12919:1999 | Workplace atmospheres - Pumps for the sampling of chemical agents with a volume flow rate of over 5 l/min - Requirements and test methods |
ASTM D 4840 : 1999 | Standard Guide for Sampling Chain-of-Custody Procedures |
ISO 7708:1995 | Air quality — Particle size fraction definitions for health-related sampling |
ISO 8655-1:2002 | Piston-operated volumetric apparatus Part 1: Terminology, general requirements and user recommendations |
ISO 3585:1998 | Borosilicate glass 3.3 — Properties |
ISO 8756:1994 | Air quality Handling of temperature, pressure and humidity data |
ISO 1042:1998 | Laboratory glassware — One-mark volumetric flasks |
ISO 648:2008 | Laboratory glassware — Single-volume pipettes |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
CEN/TR 15230:2005 | Workplace atmospheres - Guidance for sampling of inhalable, thoracic and respirable aerosol fractions |
ISO 8655-2:2002 | Piston-operated volumetric apparatus Part 2: Piston pipettes |
EN 13205:2001 | Workplace atmospheres - Assessment of performance of instruments for measurement of airborne particle concentrations |
EN 1540:2011 | Workplace exposure - Terminology |
EN 1232:1997 | Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods |
ISO 8655-6:2002 | Piston-operated volumetric apparatus Part 6: Gravimetric methods for the determination of measurement error |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.