BS ISO 16000-24:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Indoor air Performance test for evaluating the reduction of volatile organic compound (except formaldehyde) concentrations by sorptive building materials
Hardcopy , PDF
12-08-2018
English
01-31-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Principle
6 Apparatus and materials
7 Test conditions
8 Verification of test conditions
9 Preparation of test chamber
10 Preparation of test specimens
11 Test methods
12 Determination of target compounds
13 Expression of results
14 Test report
Annex A (normative) - Sample tube test for long-term
reduction performance
Annex B (normative) - System for quality assurance and
quality control
Bibliography
Describes a general laboratory test method for evaluating the reduction in concentration of volatile organic compounds (VOCs) (except formaldehyde) by sorptive building materials.
Committee |
EH/2/5
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ISO 16000-24:2009 | Identical |
ISO 16017-1:2000 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling |
ASHRAE HDBK FUNDAMENTALS : 2013 | ASHRAE HANDBOOK - FUNDAMENTALS |
ISO 6353-3:1987 | Reagents for chemical analysis — Part 3: Specifications — Second series |
ISO 16000-9:2006 | Indoor air — Part 9: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test chamber method |
ISO 16000-3:2011 | Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method |
ISO 554:1976 | Standard atmospheres for conditioning and/or testing — Specifications |
ISO 16000-11:2006 | Indoor air — Part 11: Determination of the emission of volatile organic compounds from building products and furnishing — Sampling, storage of samples and preparation of test specimens |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |