• There are no items in your cart

BS ISO 11171:2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Hydraulic fluid power. Calibration of automatic particle counters for liquids

Available format(s)

Hardcopy , PDF

Superseded date

07-31-2023

Superseded by

BS ISO 11171:2020

Language(s)

English

Published date

10-31-2016

US$359.44
Excluding Tax where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Materials and equipment
5 Sequence of APC calibration procedures
6 Sizing calibration procedure
7 Data presentation
8 Identification statement
Annex A (normative) - Preliminary APC check
Annex B (normative) - Coincidence error procedure
Annex C (normative) - Flow rate limit determination
Annex D (normative) - Resolution determination
Annex E (normative) - Verification of particle-counting accuracy
Annex F (normative) - Preparation and verification of bottles of
        secondary calibration suspensions
Annex G (informative) - APC calibration round robin
Annex H (informative) - Sample calculations
Annex I (informative) - Verification of particle size distribution
        of calibration samples
Bibliography

Describes procedures for: a) primary particle-sizing calibration, sensor resolution and counting performance of automatic particle counters (APCs) for liquids capable of analysing bottle samples; b) secondary particle-sizing calibration using suspensions verified with a primary calibrated APC; c) establishing acceptable operation and performance limits; d) verifying particle sensor performance using a truncated test dust; and e) determining coincidence and flow rate limits.

Committee
MCE/18/-/6
DevelopmentNote
Supersedes 98/700803 DC and BS 5540-2(1992). (05/2002) Supersedes 09/30171027 DC. (11/2010)
DocumentType
Standard
Pages
62
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This International Standard specifies procedures for the following: primary particle-sizing calibration, sensor resolution and counting performance of automatic particle counters (APCs) for liquids capable of analysing bottle samples; secondary particle-sizing calibration using suspensions verified with a primary calibrated APC; establishing acceptable operation and performance limits; verifying particle sensor performance using a truncated test dust; determining coincidence and flow rate limits.

Standards Relationship
ISO 11171:2016 Identical

ISO 5598:2008 Fluid power systems and components Vocabulary
ISO/TR 16144:2002 Hydraulic fluid power Calibration of liquid automatic particle counters Procedures used to certify the standard reference material SRM 2806
MIL-PRF-5606 Revision H:2002 HYDRAULIC FLUID, PETROLEUM BASE; AIRCRAFT, MISSILE, AND ORDNANCE
ISO 21501-3:2007 Determination of particle size distribution Single particle light interaction methods Part 3: Light extinction liquid-borne particle counter
ISO 3722:1976 Hydraulic fluid power — Fluid sample containers — Qualifying and controlling cleaning methods
ISO 16889:2008 Hydraulic fluid power Filters Multi-pass method for evaluating filtration performance of a filter element
ISO 12103-1:2016 Road vehicles — Test contaminants for filter evaluation — Part 1: Arizona test dust
ISO 4402:1991 Hydraulic fluid power — Calibration of automatic-count instruments for particles suspended in liquids — Method using classified AC Fine Test Dust contaminant

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.