BS IEC 62232:2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
Hardcopy , PDF
02-10-2018
English
07-31-2011
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Developing the evaluation plan
6 Evaluation methods
7 Uncertainty
8 Reporting
Annex A (normative) - Developing the evaluation
plan
Annex B (normative) - Defining the source-environment
plane
Annex C (informative) - Guidance on the application
of the standard to specific evaluation purposes
Annex D (normative) - Evaluation parameters
Annex E (normative) - RF field strength measurement
equipment requirements
Annex F (informative) - Basic computation implementation
Annex G (normative) - Advanced computation implementation
Annex H (normative) - Validation of computation methods
Annex I (informative) - Guidance on spatial averaging schemes
Annex J (informative) - Guidance on addressing time
variation of signals in measurement
Annex K (informative) - Guidance on determining ambient field
levels
Annex L (informative) - Guidance on comparing evaluated
parameters with a limit value
Annex M (informative) - Guidance on assessment schemes
Annex N (informative) - Guidance on specific technologies
Annex O (informative) - Guidance on uncertainty
Annex P (informative) - Case studies
Bibliography
Gives methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure.
Committee |
GEL/106
|
DevelopmentNote |
Supersedes 08/30136850 DC. (08/2011)
|
DocumentType |
Standard
|
Pages |
184
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
This International Standard provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This standard: considers RBS which transmit on one or more antennas using one or more frequencies in the range 300 MHz to 6 GHz; describes several RF field strength and SAR measurement and computation methodologies with guidance on their applicability to address both the in situ evaluation of installed RBS and laboratory-based evaluations; describes how surveyors with a sufficient level of expertise shall establish their specific evaluation procedures appropriate for their evaluation purpose; considers the evaluation purposes, namely: product conformity: to establish that a RBS conforms to a defined set of limit conditions under its intended use; compliance boundary: to establish the compliance boundary or boundaries for a RBS in relation to a defined set of limit conditions; to evaluate RF field strength or SAR values at one or more evaluation locations, namely: evaluation location(s) at arbitrary locations outside the control boundary to provide information for interested parties; evaluation location(s) at the control boundary to confirm validity of control boundary; evaluation location(s) within the control boundary with the specific conditions relevant to investigate an alleged over-exposure incident; provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value; provides informative guidance on how to evaluate ambient RF field strength levels in the vicinity of a RBS from RF sources other than the RBS under evaluation and at frequencies within and outside the range 300 MHz to 6 GHz; provides short descriptions of the informative example case studies to aid the surveyor given in the companion Technical Report IEC 62669 [54].
Standards | Relationship |
IEC 62232:2017 | Identical |
IEC 62232:2011 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 62209-2:2010 | Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
IEC 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
IEC 60050-531:1974 | International Electrotechnical Vocabulary (IEV) - Part 531: Electronic tubes |
IEC 62479:2010 | Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
IEC 60215:2016 | Safety requirements for radio transmitting equipment - General requirements and terminology |
CISPR TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests |
IEEE C95.3-2002 | IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz |
EN 50492 : 2008 AMD 1 2014 | BASIC STANDARD FOR THE IN-SITU MEASUREMENT OF ELECTROMAGNETIC FIELD STRENGTH RELATED TO HUMAN EXPOSURE IN THE VICINITY OF BASE STATIONS |
IEC TR 62630:2010 | Guidance for evaluating exposure from multiple electromagnetic sources |
IEEE C95.1-2005 | IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz |
IEC 62311:2007 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
IEEE 145-2013 REDLINE | IEEE Standard for Definitions of Terms for Antennas |
IEC 60050-121:1998 | International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism |
TR 102 457 : 1.1.1 | TRANSMISSION AND MULTIPLEXING (TM); STUDY ON THE ELECTROMAGNETIC RADIATED FIELD IN FIXED RADIO SYSTEMS FOR ENVIRONMENTAL ISSUES |
IEC 60050-705:1995 | International Electrotechnical Vocabulary (IEV) - Part 705: Radio wave propagation |
IEC 60050-712:1992 | International Electrotechnical Vocabulary (IEV) - Part 712: Antennas |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
IEC TR 62669:2011 | Case studies supporting IEC 62232 - Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |