BS IEC 61513:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Nuclear power plants. Instrumentation and control important to safety. General requirements for systems
Hardcopy , PDF
03-31-2013
English
09-30-2011
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Overall I&C safety life cycle
6 System safety life cycle
7 Overall integration and commissioning
8 Overall operation and maintenance
Annex A (informative) - Basic safety issues in the NPP
Annex B (informative) - Categorisation of functions and
classification of systems
Annex C (informative) - Qualitative defence approach
against CCF
Annex D (informative) - Relations of IEC 61508 with
IEC 61513 and standards of the nuclear
application sector
Annex E (informative) - Changes to be performed in later
revisions of SC 45A standards to adapt to this
version of IEC 61513
Bibliography
Specifies requirements and recommendations for the overall I&C architecture which may contain either or both technologies.
Committee |
NCE/8
|
DevelopmentNote |
Supersedes 97/708133 DC. (05/2005) Supersedes 09/30176792 DC. (10/2011)
|
DocumentType |
Standard
|
Pages |
102
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Instrumentation and control (I&C) systems important to safety may be implemented using conventional hard-wired equipment, computer-based (CB) equipment or by using a combination of both types of equipment (see Note 1). IEC 61513:2011 provides requirements and recommendations for the overall I&C architecture which may contain either or both technologies. The main technical changes with regard to the previous edition are as follows:
- alignment with the latest revisions of IAEA documents;
- alignment with new editions of IEC 60880, IEC 61226, IEC 62138, IEC 62340 and IEC 60987;
- alignment with significant advances of software engineering techniques;
- integration of requirements for staff training.
Standards | Relationship |
IEC 61513:2011 | Identical |
IEC 62391-1:2006 | Identical |
BS 6739:2009 | Code of practice for instrumentation in process control systems: installation design and practice |
08/30136724 DC : DRAFT MAY 2008 | BS 6739 - CODE OF PRACTICE FOR INSTRUMENTATION IN PROCESS CONTROL SYSTEMS - INSTALLATION DESIGN AND PRACTICE |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 60671:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Surveillance testing |
IEC 62342:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Management of ageing |
IEEE 610 : 1991 | COMPUTER DICTIONARY - A COMPILATION OF IEEE STANDARD COMPUTER GLOSSARIES |
IEEE 828-2012 | IEEE Standard for Configuration Management in Systems and Software Engineering |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
IEC 61500:2009 | Nuclear power plants - Instrumentation and control important to safety - Data communication in systems performing category A functions |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
IEC 61069-1:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 1: Terminology and basic concepts |
IEC 62003:2009 | Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing |
IEC 62381:2012 | Automation systems in the process industry - Factory acceptance test (FAT), site acceptance test (SAT), and site integration test (SIT) |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 62340:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for coping with common cause failure (CCF) |
IEC 60980:1989 | Recommended practices for seismic qualification of electrical equipment of the safety system for nuclear generating stations |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 60987:2007+AMD1:2013 CSV | Nuclear power plants - Instrumentation and control important to safety - Hardware design requirements for computer-based systems |
ISO 8402:1994 | Quality management and quality assurance — Vocabulary |
IEC 60965:2016 | Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
ISO/IEC 12207:2008 | Systems and software engineering — Software life cycle processes |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60780:1998 | Nuclear power plants - Electrical equipment of the safety system - Qualification |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
IEC 61225:2005 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for electrical supplies |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
IEC 60709:2004 | Nuclear power plants - Instrumentation and control systems important to safety - Separation |
IEC 60964:2009 | Nuclear power plants - Control rooms - Design |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
ISO 10007:2017 | Quality management — Guidelines for configuration management |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.