BS IEC 60951-1:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Nuclear power plants. Instrumentation important to safety. Radiation monitoring for accident and post-accident conditions General requirements
Hardcopy , PDF
12-01-2022
English
09-30-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Design principles
4.1 Basic requirements related to functions
4.2 Measurement range
4.3 Energy response
4.4 Minimum detectable activity (or limit of detection)
4.5 Precision (or repeatability)
4.6 Accuracy (or relative error)
4.7 Measurement time
4.8 Response time
4.9 Overload performance
4.10 Ambient background shielding or compensation devices
4.11 Requirements related to accident conditions
4.12 Reliability
4.13 User interface
4.13.1 General
4.13.2 Display of measured value
4.13.3 Alarms
4.13.4 Status indication
4.13.5 Local indications
4.14 System testing, maintenance facilities and ease of
decontamination
4.14.1 System testing
4.14.2 Maintenance facilities
4.14.3 Ease of decontamination
4.15 Electromagnetic interference
4.16 Power supplies
4.17 Interfaces
4.18 Sampling assembly
4.19 Quality
4.20 Type test report and certificate
5 Functional testing
5.1 General
5.2 General test procedures
5.2.1 General
5.2.2 Tests performed under standard test conditions
5.2.3 Tests performed with variation of influence
quantities
5.2.4 Calculations and/or numerical simulations
5.2.5 Reference sources
5.2.6 Statistical fluctuations
5.3 Performance characteristics
5.3.1 Reference response
5.3.2 Sensitivity and relative response for solid
sources
5.3.3 Accuracy (relative error)
5.3.4 Response to other artificial radionuclides
5.3.5 Response to background radiation
5.3.6 Precision (or repeatability)
5.3.7 Stability of the indication
5.3.8 Response time
5.3.9 Overload test
5.4 Electrical performance tests
5.4.1 Alarm trip range
5.4.2 Alarm trip stability
5.4.3 Fault alarm
5.4.4 Status indication and fault alarm tests
5.4.5 Warm-up time - Detection and measuring
assembly
5.4.6 Influence of supply variations
5.4.7 Short circuit withstand tests
5.5 Environmental performance test
5.5.1 Stability of performance after storage
5.5.2 Mechanical tests
5.5.3 Stability of performance with variation of
temperature and humidity
5.5.4 Electromagnetic compatibility
Bibliography
Describes general guidance on the design principles and performance criteria for equipment to measure radiation and fluid (gaseous effluents or liquids) radioactivity levels at nuclear power plants during and after an accident.
Committee |
NCE/8
|
DevelopmentNote |
Supersedes 07/30172925 DC. (09/2009) Reviewed and confirmed by BSI, August 2016. (07/2016)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 60951-1:2009 provides general guidance on the design principles and performance criteria for equipment to measure radiation and fluid (gaseous effluents or liquids) radioactivity levels at nuclear power plants during and after an accident. It specifies the general characteristics, general test procedures, radiation, electrical, safety and environmental characteristics and the identification and certification of the equipment. The main technical changes with regard to the previous edition are as follows:
- clarify the definitions;
- up-date the references to new standards published since the first edition;
- update the units of radiation.
Standards | Relationship |
IEC 60951-1:2009 | Identical |
IEC 60038:2009 | IEC standard voltages |
IEC 60951-2:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 2: Equipment for continuous off-line monitoring of radioactivity in gaseous effluents and ventilation air |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 61559-2:2002 | Radiation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 2: Requirements for discharge, environmental, accident, or post-accident monitoring functions |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
IEC 60532:2010 | Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
IEC 61069-1:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 1: Terminology and basic concepts |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60761-2:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 2: Specific requirements for radioactive aerosol monitors including transuranic aerosols |
IEC 60761-3:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 3: Specific requirements for radioactive noble gas monitors |
IEC 60761-4:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 4: Specific requirements for radioactive iodine monitors |
IEC 60980:1989 | Recommended practices for seismic qualification of electrical equipment of the safety system for nuclear generating stations |
IEC 60987:2007+AMD1:2013 CSV | Nuclear power plants - Instrumentation and control important to safety - Hardware design requirements for computer-based systems |
IEC 61504:2017 | Nuclear facilities - Instrumentation and control systems important to safety - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 62302:2007 | Radiation protection instrumentation - Equipment for sampling and monitoring radioactive noble gases |
IEC 60951-3:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 3: Equipment for continuous high range area gamma monitoring |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60861:2006 | Equipment for monitoring of radionuclides in liquid effluents and surface waters |
ISO 2889:2010 | Sampling airborne radioactive materials from the stacks and ducts of nuclear facilities |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60951-4:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 4: Equipment for continuous in-line or on-line monitoring of radioactivity in process streams |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
IEC 60780:1998 | Nuclear power plants - Electrical equipment of the safety system - Qualification |
IEC 60761-1:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 1: General requirements |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
IEC 60768:2009 | Nuclear power plants - Instrumentation important to safety - Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60050-393:2003 | International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.