BS IEC 60092-502:1999
Current
The latest, up-to-date edition.
Electrical installation in ships Tankers. Special features
Hardcopy , PDF
English
02-25-2002
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Area classification
4.1 General
4.2 Tankers carrying flammable liquids other than
liquefied gases having a flashpoint not
exceeding 60 degree C, for example crude oil,
oil products, chemical products
4.3 Tankers carrying flammable liquids having a
flashpoint exceeding 60 degree C.
4.4 Tankers carrying flammable liquefied gases
4.5 Tankers carrying cargoes (for example acids)
reacting with other products/materials to
evolve flammable gases
5 Electrical systems
5.1 Sources of electrical power
5.2 Distribution systems
5.3 Electrical protection
5.4 Equipotential bonding
5.5 Static electricity
5.6 Lightning protection
5.7 Cathodically protected metallic parts
5.8 Electromagnetic radiation
6 Electrical equipment
6.1 General
6.2 Selection of electrical equipment
6.3 Certified safe type equipment
6.4 Electrical equipment of the type "n" and that
which ensures the absence of sparks and arcs
and of "hot spots" during its normal operation
6.5 Electrical equipment in hazardous areas
6.6 Movable equipment
7 Installation
7.1 General
7.2 Selection of apparatus
7.3 Wiring system - general
7.4 Cable wiring systems
7.5 Connection of cables
7.6 Cable joints
8 Ventilation and pressurisation
8.1 General
8.2 Design principle
8.3 Ventilation related to area classification
8.4 Protection by over-pressure
9 Inspection and maintenance
9.1 General
9.2 Inspection and testing
9.3 Isolation of apparatus
9.4 Maintenance
9.5 Qualifications of personnel
10 Documentation
10.1 Area classification
10.2 Equipment
10.3 Installation
10.4 Maintenance
10.5 Administration of the documentation
Annex A (informative) Examples of hazardous area
classification - Basic principles
Annex B (informative) Examples of hazardous area
classification - Tankers carrying
flammable liquids other than liquefied
gases having a flashpoint not
exceeding 60 degree C, for example,
crude oil, oil products, chemical
products
Annex C (informative) Examples of hazardous area
classification - Tankers carrying
flammable liquids having a flashpoint
exceeding 60 degree C. - Unheated
cargoes and cargoes heated to
temperature (TH) below, and not within
15 degree C. of, their flashpoint (FP)
Annex D (informative) Examples of hazardous area
classification - Tankers carrying
flammable liquefied gases
Annex E (informative) Examples of hazardous area
classification - Tanker carrying
cargoes (for example acids) reacting
with other products/materials to
evolve flammable gases
Deals with the electrical installations in tankers carrying liquids which are flammable, either inherently, or due to their reaction with other substances, or flammable liquefied gases.
Committee |
JPEL/18
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Standards | Relationship |
IEC 60092-502:1999 | Identical |
BS 8450:2006 | Code of practice for installation of electrical and electronic equipment in ships |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 60079-10:2002 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60092-201:1994 | Electrical installations in ships - Part 201: System design - General |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC TR 60079-12:1978 | Electrical apparatus for explosive gas atmospheres - Part 12:Classification of mixtures of gases of vapours with air accordingto their maximum experimental safe gaps and minimum ignitingcurrents |
IEC 60092-101:1994+AMD1:1995 CSV | Electrical installations in ships - Part 101: Definitions and general requirements |
IEC 60092-202:2016 | Electrical installations in ships - Part 202: System design - Protection |
IEC 60092-401:1980 | Electrical installations in ships - Part 401: Installation and test of completed installation |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.