BS EN ISO 20988:2007
Current
The latest, up-to-date edition.
Air quality. Guidelines for estimating measurement uncertainty
Hardcopy , PDF
English
07-31-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Basic concepts
5.1 Outline
5.2 Measurement uncertainty
5.3 Correction for systematic effects
5.4 Provision of input data
6 Problem specification
6.1 Objectives
6.2 Measurement
6.3 Uncertainty parameters
6.4 Input data
6.4.1 General
6.4.2 Assessment of representativeness
6.5 Effects not described by series of
observations
7 Statistical analysis
7.1 Objectives
7.2 Indirect approach
7.3 Direct approach
7.4 Statistical validity
8 Estimation of variances and covariances
8.1 General
8.2 Variance estimates of Type A
8.3 Variance estimates of Type B
8.4 Estimation of covariances
9 Evaluation of uncertainty parameters
9.1 Objective
9.2 Combined standard uncertainty
9.3 Expanded uncertainty
9.3.1 General
9.3.2 Expanded uncertainty of results exhibiting
a Gaussian distribution
10 Reporting
Annex A (informative) Testing a coverage probability
Annex B (informative) Type A evaluation methods for
experimental designs A1 to A8
Annex C (informative) Examples
Bibliography
Provides comprehensive guidance and specific statistical procedures for uncertainty estimation in air quality measurements including measurements of ambient air, stationary source emissions, indoor air, workplace atmospheres and meteorology.
Committee |
EH/2/4
|
DevelopmentNote |
Supersedes 04/30126446 DC. (07/2007) Reviewed and confirmed by BSI, October 2010. (09/2010)
|
DocumentType |
Standard
|
Pages |
92
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard provides comprehensive guidance and specific statistical procedures for uncertainty estimation in air quality measurements including measurements of ambient air, stationary source emissions, indoor air, workplace atmospheres and meteorology. It applies the general recommendations of the Guide to the Expression of Uncertainty in Measurement (GUM) to boundary conditions met in air quality measurement. The boundary conditions considered include measurands varying rapidly in time, as well as the presence of bias in a series of observations obtained under conditions of intended use of methods of air quality measurement.
The methods of measurement considered comprise
-
methods corrected for systematic effects by repeated observation of reference materials,
-
methods calibrated by paired measurement with a reference method,
-
methods not corrected for systematic effects because they are unbiased by design, and
-
methods not corrected for systematic effects in intended use deliberately taking into account a bias.
Experimental data for uncertainty estimation can be provided either by a single experimental design in a direct approach or by a combination of different experimental designs in an indirect approach.
Standards | Relationship |
UNI EN ISO 20988 : 2007 | Identical |
NS EN ISO 20988 : 1ED 2007 | Identical |
I.S. EN ISO 20988:2007 | Identical |
EN ISO 20988:2007 | Identical |
NF EN ISO 20988 : 2007 | Identical |
NEN EN ISO 20988 : 2007 | Identical |
UNE-EN ISO 20988:2008 | Identical |
NBN EN ISO 20988 : 2007 | Identical |
SN EN ISO 20988 : 2007 | Identical |
ISO 20988:2007 | Identical |
DIN EN ISO 20988:2007-09 | Identical |
ISO/IEC Guide 98:1993 | Guide to the expression of uncertainty in measurement (GUM) |
ISO 5725-3:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method |
ISO 5725-4:1994 | Accuracy (trueness and precision) of measurement methods and results Part 4: Basic methods for the determination of the trueness of a standard measurement method |
ISO/TS 21748:2004 | Guidance for the use of repeatability, reproducibility and trueness estimates in measurement uncertainty estimation |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ISO 16107:2007 | Workplace atmospheres Protocol for evaluating the performance of diffusive samplers |
ISO 11222:2002 | Air quality — Determination of the uncertainty of the time average of air quality measurements |
ISO 5725-5:1998 | Accuracy (trueness and precision) of measurement methods and results — Part 5: Alternative methods for the determination of the precision of a standard measurement method |
ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.