BS EN ISO 1135-4:2015
Current
The latest, up-to-date edition.
Transfusion equipment for medical use Transfusion sets for single use, gravity feed
Hardcopy , PDF
English
02-29-2016
Foreword
1 Scope
2 Normative references
3 General requirements
4 Materials
5 Physical requirements
6 Chemical requirements
7 Biological requirements
8 Labelling
9 Packaging
10 Disposal
Annex A (normative) - Physical tests
Annex B (normative) - Chemical tests
Annex C (normative) - Biological tests
Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the Essential Requirements
of EC Directive 93/42/EEC on medical devices
Describes requirements for single-use transfusion gravity sets for medical use in order to ensure their compatibility with containers for blood and blood components as well as with intravenous equipment.
Committee |
CH/212
|
DevelopmentNote |
Supersedes 02/564513 DC. (08/2004) Together with BS EN ISO 3826-1 and BS EN ISO 3826-3, supersedes BS 2463-1(1990) and BS 2463-2(1989). (04/2007) Supersedes 08/30184486 DC. (05/2010) Supersedes 13/30283691 DC. (02/2016)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO 1135 specifies requirements for single use transfusion gravity sets for medical use in order to ensure their compatibility with containers for blood and blood components as well as with intravenous equipment.
Secondary aims of this part of ISO 1135 are to provide guidance on specifications relating to the quality and performance of materials used in transfusion sets, to present designations for transfusion set components, and to ensure the compatibility of sets with a range of cellular and plasma blood components.
In some countries, the national pharmacopoeia or other national regulations are legally binding and take precedence over this part of ISO 1135.
Standards | Relationship |
NF EN ISO 1135-4 : 2016 | Identical |
UNI EN ISO 1135-4 : 2012-06 | Identical |
UNE-EN ISO 1135-4:2016 | Identical |
NBN EN ISO 1135-4 : 2016 | Identical |
I.S. EN ISO 1135-4:2015 | Identical |
NEN EN ISO 1135-4 : 2016 | Identical |
ISO 1135-4:2015 | Identical |
DIN EN ISO 1135-4:2016-06 | Identical |
NS EN ISO 1135-4 : 2012 | Identical |
EN ISO 1135-4 : 2015 COR 2016 | Identical |
EN ISO 1135-4:2015 | Identical |
ISO 3826-2:2008 | Plastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on labels and instruction leaflets |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
EN 15986:2011 | Symbol for use in the labelling of medical devices - Requirements for labelling of medical devices containing phthalates |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
ISO 3826-1:2013 | Plastics collapsible containers for human blood and blood components Part 1: Conventional containers |
ISO 7864:2016 | Sterile hypodermic needles for single use — Requirements and test methods |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 291:2008 | Plastics Standard atmospheres for conditioning and testing |
IEC 80416-1:2008 | Basic principles for graphical symbols for use on equipment - Part 1: Creation of graphical symbols for registration |
ISO 14644-1:2015 | Cleanrooms and associated controlled environments Part 1: Classification of air cleanliness by particle concentration |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
ISO 594-1:1986 | Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 1: General requirements |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.