BS EN ISO 10846-3:2002
Current
The latest, up-to-date edition.
Acoustics and vibration. Laboratory measurement of vibro-acoustic transfer properties of resilient elements Indirect method for determination of the dynamic stiffness of resilient supports for translatory motion
Hardcopy , PDF
English
04-03-2003
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principles
5 Requirements for apparatus
5.1 Normal translations
5.2 Transverse translations
5.3 Suppression of unwanted vibrations
6 Criteria for adequacy of the test arrangement
6.1 Frequency range
6.2 Determination of upper frequency limit f[3]
6.3 Flanking transmission
6.4 Unwanted input vibrations
6.5 Accelerometers
6.6 Force transducers
6.7 Summation of signals
6.8 Analysers
7 Test procedures
7.1 Installation of the test elements
7.2 Mounting and connection of accelerometers
7.3 Mounting and connections of the vibration exciter
7.4 Source signal
7.5 Measurements
7.6 Test for linearity
8 Evaluation of test results
8.1 Evaluation of dynamic transfer stiffness
8.2 One-third-octave-bad values of the frequency averaged dynamic
transfer stiffness
8.3 Presentation of one-third-octave-band results
8.4 Presentation of narrow-band data
9 Information to be recorded
10 Test report
Annex A (informative) Transfer stiffness related to rotatory
vibration components
Annex B (informative) Effect of symmetry on the transfer stiffness
matrix
Annex C (informative) Static load-deflection curve
Bibliography
Defines a method for determining the dynamic transfer stiffness for translations of resilient supports, under specific preload.
Committee |
EH/1/4
|
DevelopmentNote |
Supersedes 97/560673 DC (04/2003)
|
DocumentType |
Standard
|
Pages |
50
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO 10846 specifies a method for determining the dynamic transfer stiffness for translations of resilient supports, under specific preload. The method concerns the laboratory measurements of vibration transmissibility and is called the indirect method. This method is applicable to test elements with parallel flanges (see Figure 1).
NOTE 1 Vibration isolators which are the subject of this part of ISO 10846 are those which are used to reduce the transmission of audiofrequency vibrations (structureborne sound, 20 Hz to 20 kHz) to a structure which may, for example, radiate unwanted fluidborne sound (airborne, waterborne or other).
NOTE 2 In practice the size of the available test rig(s) can give restrictions for very small and for very large resilient supp orts.
NOTE 3 Samples of continuous supports of strips and mats are included in the method. Whether or not the sample describes the behaviour of the complex system sufficiently, is the responsibility of the user of this part of ISO 10846.
Measurements for translations normal and transverse to the flanges are covered in this part of ISO 10846. Annex A provides guidance for the measurement of transfer stiffnesses which include rotatory components.
The method covers the frequency range from f2 up to f3. The values of f2 and f3 are determined by the test set-up and the isolator under test. Typically 20 Hz ≤ f2 ≤ 50 Hz and 2 kHz ≤ f3 ≤ 5 kHz.
The data obtained according to the method specified in this part of ISO 10846 can be used for
product information provided by manufacturers and suppliers,
information during product development,
quality control, and
calculation of the transfer of vibration through isolators.
NOTE 1 When a resilient support has no parallel flanges, an auxiliary fixture should be included as part of the test element to arrange for parallel flanges.
NOTE 2 Arrows indicate load direction.
Standards | Relationship |
NS EN ISO 10846-3 : 1ED 2002 | Identical |
SN EN ISO 10846-3 : 2002 | Identical |
DIN EN ISO 10846-3:2003-06 | Identical |
NBN EN ISO 10846-3 : 2002 | Identical |
NF EN ISO 10846-3 : 2002 | Identical |
EN ISO 10846-3:2002 | Identical |
I.S. EN ISO 10846-3:2002 | Identical |
ISO 10846-3:2002 | Identical |
UNE-EN ISO 10846-3:2003 | Identical |
NEN EN ISO 10846-3 : 2002 | Identical |
UNI EN ISO 10846-3 : 2005 | Identical |
ISO 7626-1:2011 | Mechanical vibration and shock — Experimental determination of mechanical mobility — Part 1: Basic terms and definitions, and transducer specifications |
ISO 5347-3:1993 | Methods for the calibration of vibration and shock pick-ups Part 3: Secondary vibration calibration |
ISO 266:1997 | Acoustics — Preferred frequencies |
ISO 7626-2:2015 | Mechanical vibration and shock Experimental determination of mechanical mobility Part 2: Measurements using single-point translation excitation with an attached vibration exciter |
ISO 2041:2009 | Mechanical vibration, shock and condition monitoring Vocabulary |
ISO 10846-1:2008 | Acoustics and vibration — Laboratory measurement of vibro-acoustic transfer properties of resilient elements — Part 1: Principles and guidelines |
ISO 2017:1982 | Vibration and shock Isolators Procedure for specifying characteristics |
ISO 5348:1998 | Mechanical vibration and shock Mechanical mounting of accelerometers |
EN ISO 266:1997 | Acoustics - Preferred frequencies (ISO 266:1997) |