BS EN 636 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PLYWOOD - SPECIFICATIONS
Hardcopy , PDF
07-03-2019
English
01-01-2012
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and subscripts
5 Classification system
6 General requirements
7 Requirements for plywood for use in dry conditions
8 Requirements for plywood for use in humid conditions
9 Requirements for plywood for use in exterior conditions
10 Supplementary properties
11 Verification of compliance
12 Marking, identification and documentation
Annex A (normative) - Supplementary properties
Bibliography
Defines the requirements for plywood, as defined in EN 313-2, for both general purpose use (non-structural application) and structural application in dry, humid or exterior conditions.
Committee |
B/541
|
DevelopmentNote |
Supersedes BS EN 636-1, BS EN 636-2 & BS EN 636-3 (08/2003) Supersedes 10/30234290 DC. (01/2013) 2012 Edition Re-Issued in April 2015 & incorporates AMD 1 2015. Supersedes 14/30300920 DC. (05/2015)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 636:2012 | Identical |
NBN EN 636 : 2012 + A1 2015 | Identical |
NEN EN 636 : 2012 + A1 2015 | Identical |
EN 636:2012+A1:2015 | Identical |
SN EN 636 : 2012 + A1 2015 | Identical |
NF EN 636 : 2012 + A1 2015 | Identical |
DIN EN 636:2015-05 | Identical |
NS EN 636 : 2012 + A1 2015 | Identical |
I.S. EN 636:2012 | Identical |
UNI EN 636 : 2013 | Identical |
08/30140202 DC : 0 | BS 8103-3 - STRUCTURAL DESIGN OF LOW-RISE BUILDINGS - PART 3: CODE OF PRACTICE FOR TIMBER FLOORS AND ROOFS FOR HOUSING |
BS 1133-8(2011) : 2011 | PACKAGING CODE - PART 8: GUIDANCE ON WOODEN BOXES, CASES AND CRATES |
BS 8203:2017 | Code of practice for installation of resilient floor coverings |
BS 5534(2014) : 2014 | SLATING AND TILING FOR PITCHED ROOFS AND VERTICAL CLADDING - CODE OF PRACTICE |
BS 8203(2001) : 2001 | CODE OF PRACTICE FOR INSTALLATION OF RESILIENT FLOOR COVERINGS |
DEFSTAN 81-27/7(2015) : 2015 | PLYWOOD FOR MILITARY PACKAGING APPLICATIONS |
DEFSTAN 81-148/1(2017) : 2017 | BOARD, PROCESSED WOOD FOR GENERAL PACKAGING |
DEFSTAN 81-41(PT2)/8(2015) : 2015 | PACKAGING OF DEFENCE MATERIEL - PART 2: DESIGN |
DEFSTAN 81-27/6(2008) : 2008 | PLYWOOD FOR MILITARY PACKAGING APPLICATIONS |
DEFSTAN 81-41(PT2)/7(2014) : 2014 | PACKAGING OF DEFENCE MATERIEL - PART 2: DESIGN |
BS 5385-3:2014 | Wall and floor tiling Design and installation of internal and external ceramic and mosaic floor tiling in normal conditions. Code of practice |
11/30197409 DC : DRAFT JULY 2011 | BS 1133-8 - PACKAGING CODE - PART 8: GUIDANCE ON WOODEN BOXES, CASES AND CRATES - SECTION 8: WOODEN BOXES, CASES AND CRATES |
05/30121961 DC : DRAFT JUL 2005 | BS 4841-3 - RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) PRODUCTS FOR BUILDING AND END-USE APPLICATIONS - PART 3: SPECIFICATION FOR LAMINATED INSULATION BOARDS (ROOFBOARDS) WITH AUTO-ADHESIVELY BONDED FACINGS FOR USE AS ROOFBOARD THERMAL INSULATION FOR BUILT-UP ROOFS UNDER BITUMENISED ROOFING MEMBRANES |
BS 5268-2:2002 | Structural use of timber Code of practice for permissible stress design, materials and workmanship |
BS 8103-3:2009 | Structural design of low-rise buildings Code of practice for timber floors and roofs for housing |
BS 8217:2005 | Reinforced bitumen membranes for roofing. Code of practice |
BS 8201:2011 | Code of practice for installation of flooring of wood and wood-based panels |
BS 4841-3:2006 | Rigid polyisocyanurate (PIR) and polyurethane (PUR) products for building end-use applications Specification for laminated boards (roofboards) with auto-adhesively or separately bonded facings for use as roofboard thermal insulation under built up bituminous roofing membranes |
BS 4841-4:2006 | Rigid polyurethane (PUR) and polyisocyanurate (PIR) products for building end-use applications Specification for laminated insulation boards (roofboards) with auto-adhesively or separately bonded facings for use as roofboard thermal insulation under non-bituminous single-ply roofing membranes |
11/30209204 DC : 0 | BS 8201 - CODE OF PRACTICE FOR INSTALLATION OF FLOORING OF WOOD AND WOOD-BASED PANELS |
14/30283603 DC : 0 | BS 5385-3 - WALL AND FLOOR TILING - PART 3: DESIGN AND INSTALLATION OF INTERNAL ANDEXTERNAL CERAMIC AND MOSAIC FLOOR TILING IN NORMAL CONDITIONS - CODE OF PRACTICE |
05/30124175 DC : DRAFT JUL 2005 | BS 4841-4 - RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) PRODUCTS FOR BUILDING AND END-USE APPLICATIONS - PART 4: SPECIFICATION FOR LAMINATED INSULATION BOARDS (FLOORBOARDS) WITH AUTO-ADHESIVELY BONDED FACINGS FOR USE AS ROOFBOARD THERMAL INSULATION COVERED BY SINGLE-PLY NON-BITUMINISED ROOFING MEMBRANES |
BS 10075:2013 | Specification for Parkour equipment |
DEFSTAN 81-041(PT2)/9(2017) : 2017 | PACKAGING OF DEFENCE MATERIEL - PART 2: DESIGN |
12/30242848 DC : 0 | BS 10075 - SPECIFICATION FOR PARKOUR EQUIPMENT |
09/30174199 DC : 0 | BS 8203:2001+A1:2009 - CODE OF PRACTICE FOR INSTALLATION OF RESILIENT FLOOR COVERINGS |
BS 8424:2004 | Building hardware. Pull handles. Requirements and test methods |
BIP 2198 : 2012 | CONCISE EUROCODE FOR DESIGN OF TIMBER STRUCTURES: BS EN 1995: EUROCODES 5 |
13/30271503 DC : 0 | BS 5534 - SLATING AND TILING FOR PITCHED ROOFS AND VERTICAL CLADDING - CODE OF PRACTICE |
16/30348805 DC : 0 | BS 8203 - CODE OF PRACTICE FOR INSTALLATION OF RESILIENT FLOOR COVERINGS |
EN 326-3:2003 | Wood-based panels - Sampling, cutting and inspection - Part 3: Inspection of an isolated lot of panels |
EN 635-2:1995 | Plywood - Classification by surface appearance - Part 2: Hardwood |
CEN/TS 1099:2007 | Plywood - Biological durability - Guidance for the assessment of plywood for use in different use classes |
EN 13986:2004 | Wood-based panels for use in construction - Characteristics, evaluation of conformity and marking |
EN 310:1993 | Wood-based panels - Determination of modulus of elasticity in bending and of bending strength |
CEN/TS 13810-2:2003 | Wood-based panels - Floating floors - Part 2: Test methods |
EN 326-1:1994 | Wood-based panels - Sampling, cutting and inspection - Part 1: Sampling and cutting of test pieces and expression of test results |
EN 322:1993 | Wood-based panels - Determination of moisture content |
EN 326-2:2010+A1:2014 | Wood-based panels - Sampling, cutting and inspection - Part 2: Initial type testing and factory production control |
EN 14272:2011 | Plywood - Calculation method for some mechanical properties |
EN 596:1995 | Timber structures - Test methods - Soft body impact test of timber framed walls |
EN 324-1:1993 | Wood-based panels - Determination of dimensions of boards - Part 1: Determination of thickness, width and length |
ENV 1156:1998 | Wood-based panels - Determination of duration of load and creep factors |
EN 1058:2009 | Wood-based panels - Determination of characteristic 5-percentile values and characteristic mean values |
EN 1195:1997 | Timber structures - Test methods - Performance of structural floor decking |
EN 717-1:2004 | Wood-based panels - Determination of formaldehyde release - Part 1: Formaldehyde emission by the chamber method |
EN 13446:2002 | Wood-based panels - Determination of withdrawal capacity of fasteners |
EN 13810-1:2002 | Wood-based panels - Floating floors - Part 1: Performance specifications and requirements |
EN 789:2004 | Timber structures - Test methods - Determination of mechanical properties of wood based panels |
EN 635-1:1994 | Plywood - Classification by surface appearance - Part 1: General |
EN 594:2011 | Timber structures - Test methods - Racking strength and stiffness of timber frame wall panels |
EN 324-2:1993 | Wood-based panels - Determination of dimensions of boards - Part 2: Determination of squareness and edge straightness |
EN 323:1993 | Wood-based panels - Determination of density |
EN 315:2000 | Plywood - Tolerances for dimensions |
EN 318:2002 | Wood based panels - Determination of dimensional changes associated with changes in relative humidity |
EN 335-3:1995 | Durability of wood and wood-based products - Definition of hazard classes of biological attack - Part 3: Application to wood-based panels |
EN 313-1:1996 | Plywood - Classification and terminology - Part 1: Classification |
EN 313-2:1999 | Plywood - Classification and terminology - Part 2: Terminology |
EN 314-2:1993 | Plywood - Bonding quality - Part 2: Requirements |
EN 12871:2013 | Wood-based panels - Determination of performance characteristics for load bearing panels for use in floors, roofs and walls |
EN 635-3:1995 | Plywood - Classification by surface appearance - Part 3: Softwood |
CEN/TS 635-4:2007 | Plywood - Classification by surface appearance - Part 4: Parameters of ability for finishing, guideline |
EN 12369-2:2011 | Wood-based panels - Characteristic values for structural design - Part 2: Plywood |
EN 635-5:1999 | Plywood - Classification by surface appearance - Part 5: Methods for measuring and expressing characteristics and defects |
EN 314-1:2004 | Plywood - Bonding quality - Part 1: Test methods |