BS EN 62852:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Connectors for DC-application in photovoltaic systems. Safety requirements and tests
Hardcopy
05-27-2020
English
05-31-2015
Committee |
GEL/82
|
DevelopmentNote |
Renumbers and supersedes BS IEC 62852. 2015 version incorporates corrigendum to BS IEC 62852. (05/2015)
|
DocumentType |
Standard
|
ISBN |
9780539038453
|
Pages |
44
|
ProductNote |
Impementation of CENELEC corrigendum February2019: supersession details added to CENELEC title page and Foreword Incorporating corrigendum version is available now
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 62852:2014 applies to connectors for use in the d.c. circuits of photovoltaic systems according to class II of IEC 61140:2001 with rated voltages up to 1 500 V d.c. and rated currents up to 125 A per contact. It applies to connectors without breaking capacity but which might be engaged and disengaged under voltage.
Standards | Relationship |
EN 62852:2015/AC:2019-02 | Identical |
IEC 62852:2014 | Identical |
EN 62852:2015 | Identical |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60352-3:1993 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
IEC 60068-2-70:1995 | Environmental testing - Part 2-70: Tests - Test Xb: Abrasion of markings and letterings caused by rubbing of fingers and hands |
IEC 60364-7-712:2017 | Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems |
IEC 60228:2004 | Conductors of insulated cables |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60998-2-3:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
IEC 61215:2005 | Crystalline silicon terrestrial photovoltaic (PV) modules - Design qualification and type approval |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61730-2:2016 | Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing |
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV | Plugs and socket-outlets for household and similar purposes - Part1: General requirements |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO 4892-3:2016 | Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
IEC 61730-1:2016 | Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
IEC TR 60664-2-1:2011 | Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 62444:2010 | Cable glands for electrical installations |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.