BS EN 62220-1-3:2008
Current
The latest, up-to-date edition.
Medical electrical equipment. Characteristics of digital X-ray imaging devices Determination of the detective quantum efficiency. Detectors used in dynamic imaging
Hardcopy , PDF
English
04-30-2009
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Operating conditions
4.2 X-RAY EQUIPMENT
4.3 RADIATION QUALITY
4.4 TEST DEVICE
4.5 Geometry
4.6 IRRADIATION conditions
4.6.1 General conditions
4.6.2 AIR KERMA measurement
4.6.3 LAG EFFECTS
4.6.4 IRRADIATION to obtain the CONVERSION
FUNCTION
4.6.5 IRRADIATION for determination of the NOISE
POWER SPECTRUM and LAG EFFECTS
4.6.6 IRRADIATION with TEST DEVICE in the
RADIATION BEAM
4.6.7 Overview of all necessary IRRADIATIONS
5 Corrections of RAW DATA
6 Determination of the DETECTIVE QUANTUM EFFICIENCY
6.1 Definition and formula of DQE(u,v)
6.2 Parameters to be used for evaluation
6.3 Determination of different parameters from the images
6.3.1 Linearization of data
6.3.2 The LAG EFFECTS corrected NOISE POWER
SPECTRUM (NPS)
6.3.3 Determination of the MODULATION TRANSFER
FUNCTION (MTF)
7 Format of conformance statement
8 Accuracy
Annex A (informative) - Determination of LAG EFFECTS
Annex B (informative) - Calculation of the input NOISE
POWER SPECTRUM
Bibliography
Index of defined terms
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements
of EC Directives
Describes the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER.
Committee |
CH/62/2
|
DevelopmentNote |
Supersedes 07/30161724 DC. (04/2009)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 62220-1-3:2008 specifies the method for the determination of the detective quantum efficiency (DQE) of digital X-ray imaging devices as a function of air kerma and of spatial frequency for the working conditions in the range of the medical application as specified by the manufacturer. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories. This Part 1-3 is restricted to digital X-ray imaging devices that are used for dynamic imaging such as, but not exclusively, direct and indirect flat panel-detector based systems. It is not recommended to use this part of IEC 62220 for digital X-ray image intensifier-based systems.
Standards | Relationship |
EN 62220-1-3:2008 | Identical |
IEC 62220-1-3:2008 | Identical |
EN 60317-0-6:2001 | Identical |
ISO 12232:2006 | Photography Digital still cameras Determination of exposure index, ISO speed ratings, standard output sensitivity, and recommended exposure index |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
ISO 15529:2010 | Optics and photonics Optical transfer function Principles of measurement of modulation transfer function (MTF) of sampled imaging systems |
EN 61267:2006 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
ISO/IEC Guide 98:1993 | Guide to the expression of uncertainty in measurement (GUM) |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 62220-1-2:2007 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography |
IEC 62220-1:2003 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1: Determination of the detective quantum efficiency |
ISO 12233:2017 | Photography — Electronic still picture imaging — Resolution and spatial frequency responses |
EN 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
IEC 61262-5:1994 | Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 5: Determination of the detective quantum efficiency |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.