BS EN 62040-1 : 2008
Current
The latest, up-to-date edition.
UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS
Hardcopy , PDF
English
01-01-2008
1 Scope and specific applications
2 Normative references
3 Terms and definitions
4 General conditions for tests
5 Fundamental design requirements
6 Wiring, connections and supply
7 Physical requirements
8 Electrical requirements and simulated abnormal conditions
9 Connection to telecommunication networks
Annex A (normative) - Tests for resistance to heat and fire
Annex B (normative) - Motor tests under abnormal conditions
Annex C (normative) - Transformers
Annex D (normative) - Measuring instruments for touch
current tests
Annex E (normative) - Temperature rise of a winding
Annex F (normative) - Measurements of clearances and
creepage distances
Annex G (normative) - Alternative method for determining
minimum clearances
Annex H (informative) - Guidance on protection against
ingress of water and foreign objects
Annex I (normative) - Backfeed protection test
Annex J (informative) - Table of electrochemical potentials
Annex K (normative) - Thermal controls
Annex L (normative) - Reference loads
Annex M (normative) - Ventilation of battery compartments
Annex N (normative) - Minimum and maximum cross-sections
of copper conductors suitable for connection
Annex O (informative) - Guidance for disconnection of batteries
during shipment
Annex P (informative) - Short-time withstand current
test procedure - Guidance and typical values
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to uninterruptible power systems (UPS ) with an electrical energy storage device in the d.c. link.
Committee |
PEL/22
|
DevelopmentNote |
Supersedes BS EN 62040-1-1, BS EN 62040-1-2 & 06/30158289 DC. (03/2009) 2008 Edition remains current. 2008 Edition Re-Issued in June 2013 & incorporates AMD 1 2013. Supersedes 11/30244898 DC. (07/2013)
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 62040-1:2017 EXV | Identical |
EN 62040-1:2008/A1:2013 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
DEFSTAN 08-107/3(2013) : 2013 | GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROTECHNICAL AND NAVAL WEAPON EQUIPMENT |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC TR 60725:2012 | Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase |
EN 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
NEMA 250 : 2014 | ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM) |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
EN 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV | DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements |
IEC 62040-2:2016 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
EN 61009-1:2012/A12:2016 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
IEC TR 60755:2008 | General requirements for residual current operated protective devices |
IEC 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
EN 62040-2:2006/corrigendum:2006 | |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
EN 61008-1:2012/A12:2017 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.