BS EN 61850-7-2:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Communication networks and systems for power utility automation Basic information and communication structure. Abstract communication service interface (ACSI)
Hardcopy , PDF
04-22-2020
English
01-31-2011
Committee |
PEL/57
|
DevelopmentNote |
Supersedes 00/203116 DC (11/2004) Supersedes 07/30166751 DC. (02/2011)
|
DocumentType |
Standard
|
Pages |
220
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
IEC 61850-7-2:2010 applies to the ACSI communication for utility automation. The ACSI provides the following abstract communication service interfaces:
- abstract interface describing communications between a client and a remote server;
- and abstract interface for fast and reliable system-wide event distribution between an application in one device and many remote applications in different devices (publisher/sub-scriber) and for transmission of sampled measured values (publisher/subscriber).
Major technical changes with regard to the previous edition are as follows:
- data types not required have been removed,
- service tracking for control blocks have been added,
- security issues are solved by the IEC 62351 series,
- service tracking for control blocks have been added,
- the view concept will be according to the new work on role bases access (RBA),
- security issues are solved by the IEC 62351 series.
This publication is of core relevance for Smart Grid.
Standards | Relationship |
IEC 61970-456:2013/AMD1:2015 | Identical |
SN EN 61850-7-2 : 2003 | Identical |
IEC 61850-7-2:2010 | Identical |
I.S. EN 61850-7-2:2010 | Identical |
NF EN 61850-7-2 : 2003 | Identical |
EN 61850-7-2:2010 | Identical |
DIN EN 61850-7-2:2011-04 | Identical |
IEC 61850-5:2013 | Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models |
EN 61850-6:2010 | Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs |
IEC 61850-9-1:2003 | Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link |
IEC 61850-6:2009 | Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs |
EN 61850-5:2013 | Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models |
EN 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
ISO 9506-1:2003 | Industrial automation systems Manufacturing Message Specification Part 1: Service definition |
IEC 61850-7-1:2011 | Communication networks and systems for power utility automation - Part 7-1: Basic communication structure - Principles and models |
EN 61850-7-1:2011 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-1: BASIC COMMUNICATION STRUCTURE - PRINCIPLES AND MODELS (IEC 61850-7-1:2011) |
IEC 61850-8-1:2011 | Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
EN 61850-7-3:2011 | Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes |
IEC 61850-9-2:2011 | Communication networks and systems for power utility automation - Part 9-2: Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3 |
ISO 4217:2015 | Codes for the representation of currencies |
IEC 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
IEC 61850-7-3:2010 | Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes |
IEEE 754-2008 REDLINE | IEEE Standard for Floating-Point Arithmetic |
IEC 61400-25-2:2015 | Wind turbines - Part 25-2: Communications for monitoring and control of wind power plants - Information models |
EN 61850-9-2:2011 | Communication networks and systems for power utility automation - Part 9-2: Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3 |
IEC TS 61850-2:2003 | Communication networks and systems in substations - Part 2: Glossary |
EN 61850-8-1:2011 | Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
EN 61400-25-2:2015 | Wind turbines - Part 25-2: Communications for monitoring and control of wind power plants - Information models |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.