Electric components. Reliability. Reference conditions for failure rates and stress models for conversion
Hardcopy , PDF
English
08-08-2017
Committee |
DS/1
|
DevelopmentNote |
Renumbers and supersedes BS 5760-18(1997). 2000 version incorporates amendment 10390 to BS 5760-18(1997) Supersedes 91/89537 DC. (01/2006) Supersedes 09/30184127 DC. (08/2011) Supersedes 15/30310531 DC. (08/2017)
|
DocumentType |
Standard
|
Pages |
128
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 61709:2017 is also available as IEC 61709:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61709:2017 gives guidance on the use of failure rate data for reliability prediction of electric components used in equipment. The method presented in this document uses the concept of reference conditions which are the typical values of stresses that are observed by components in the majority of applications. Reference conditions are useful since they provide a known standard basis from which failure rates can be modified to account for differences in environment from the environments taken as reference conditions. Each user can use the reference conditions defined in this document or use their own. When failure rates stated at reference conditions are used it allows realistic reliability predictions to be made in the early design phase. The stress models described herein are generic and can be used as a basis for conversion of failure rate data given at these reference conditions to actual operating conditions when needed and this simplifies the prediction approach. Conversion of failure rate data is only possible within the specified functional limits of the components. This document also gives guidance on how a database of component failure data can be constructed to provide failure rates that can be used with the included stress models. Reference conditions for failure rate data are specified, so that data from different sources can be compared on a uniform basis. If failure rate data are given in accordance with this document then additional information on the specified conditions can be dispensed with. This document does not provide base failure rates for components – rather it provides models that allow failure rates obtained by other means to be converted from one operating condition to another operating condition. The prediction methodology described in this document assumes that the parts are being used within its useful life. The methods in this document have a general application but are specifically applied to a selection of component types as defined in Clauses 6 to 20 and I.2. This third edition cancels and replaces the second edition, published in 2011. This edition constitutes a technical revision. This third edition is a merger of IEC 61709:2011 and IEC TR 62380:2004.
This edition includes the following significant technical changes with respect to the previous edition: addition of 4.5 Components choice, 4.6 Reliability growth during the deployment phase of new equipment, 4.7 How to use this document, and of Clause 19 Printed circuit boards (PCB) and Clause 20 Hybrid circuits with respect to IEC TR 62380; addition of failure modes of components in Annex A; modification of Annex B, Thermal model for semiconductors, adopted and revised from IEC TR 62380; modification of Annex D, Considerations on mission profile; modification of Annex E, Useful life models, adopted and revised from IEC TR 62380; revision of Annex F (former B.2.6.4), Physics of failure; addition of Annex G (former Annex C), Considerations for the design of a data base on failure rates, complemented with parts of IEC 60319; addition of Annex H, Potential sources of failure rate data and methods of selection; addition of Annex J, Presentation of component reliability data, based on IEC 60319.
Keywords: failure rate data, reliability prediction of electric components
Standards | Relationship |
NF EN 61709 : 2017 | Identical |
NBN EN 61709 : 2011 | Identical |
IEC 61709:2017 | Identical |
I.S. EN 61709:2017 | Identical |
SN EN 61709 : 2017 | Identical |
UNE-EN 61709:2014 | Identical |
DIN EN 61709:2015-01 (Draft) | Identical |
EN 61709:2017 | Identical |
EN 62059-32-1:2012 | Identical |
03/101534 DC : DRAFT JAN 2003 | BS 5760-4 - RELIABILITY OF SYSTEMS, EQUIPMENT AND COMPONENTS - PART 4: GUIDE TO THE SPECIFICATION OF DEPENDABILITY REQUIREMENTS |
BS 5760-4:2003 | Reliability of systems, equipment and components Guide to the specification of dependability requirements |
IEC 62308:2006 | Equipment reliability - Reliability assessment methods |
IEC 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
EN 300 019-1-5 : 2.1.4 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 1-5: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS; GROUND VEHICLE INSTALLATIONS |
IEC 60319:1999 | Presentation and specification of reliability data for electronic components |
IEC PAS 62435:2005 | Electronic components - Long-duration storage of electronic components - Guidance for implementation |
IEC 60300-3-3:2017 | Dependability management - Part 3-3: Application guide - Life cycle costing |
IEC 61649:2008 | Weibull analysis |
IEC 62741:2015 | Demonstration of dependability requirements - The dependability case |
IEC 61014:2003 | Programmes for reliability growth |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61360-4:2005 | Standard data element types with associated classification scheme for electric components - Part 4: IEC reference collection of standard data element types and component classes |
IEC 60605-6:2007 | Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity |
ETS 300 200019-1-4 : 20001 | EQUIPMENT ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS |
VITA 51.2 : 2016 | PHYSICS OF FAILURE RELIABILITY PREDICTIONS |
IEC 60721-3-7:1995+AMD1:1996 CSV | Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use |
IEC 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classificationof groups of environmental parameters and their severities -Section 5: Ground vehicle installations |
EN 300 019-1-7 : 2.1.4 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 1-7: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS; PORTABLE AND NON-STATIONARY USE |
ISO 10303-31:1994 | Industrial automation systems and integration Product data representation and exchange Part 31: Conformance testing methodology and framework: General concepts |
IEC TR 62380:2004 | Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment |
IEC 61360-1:2017 | Standard data element types with associated classification scheme - Part 1: Definitions - Principles and methods |
IEC 60650:1979 | Analogue counting ratemeters. Characteristics and test methods |
ISO 10303-11:2004 | Industrial automation systems and integration Product data representation and exchange Part 11: Description methods: The EXPRESS language reference manual |
IEC 61810-2:2017 | Electromechanical elementary relays - Part 2: Reliability |
IEC 61163-2:1998 | Reliability stress screening - Part 2: Electronic components |
DEFSTAN 00-42(PT3)/4(2011) : 2011 | RELIABILITY AND MAINTAINABILITY ASSURANCE GUIDE - PART 3: R&M CASE |
IEC 60300-3-2:2004 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
IEC 61810-2-1:2017 | Electromechanical elementary relays - Part 2-1: Reliability - Procedure for the verification of B<sub>10</sub> values |
IEC 60747-12-2:1995 | Semiconductor devices - Part 12: Optoelectronic devices - Section 2: Blank detail specification for laser diode modules with pigtail for fibre optic systems and sub-systems |
IEC 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
IEC 60747-1:2006+AMD1:2010 CSV | Semiconductor devices - Part 1: General |
MIL-C-18312 Revision G:2013 | CAPACITOR, FIXED, METALLIZED (PAPER-PLASTIC, OR PLASTIC FILM) DIELECTRIC, DIRECT CURRENT (HERMETICALLY SEALED IN METAL CASES), GENERAL SPECIFICATION FOR |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 300 019-1-8 : 2.1.4 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 1-8: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS; STATIONARY USE AT UNDERGROUND LOCATIONS |
IEC 60050-521:2002 | International Electrotechnical Vocabulary (IEV) - Part 521: Semiconductor devices and integrated circuits |
IEC 61710:2013 | Power law model - Goodness-of-fit tests and estimation methods |
ETS 300 200019-1-3 : 20001 | EQUIPMENT ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT WEATHERPROTECTED LOCATIONS |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.