BS EN 61347-2-9:2013
Current
The latest, up-to-date edition.
Lamp controlgear Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
Hardcopy , PDF
English
01-31-2013
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength test for windings
13 Thermal endurance test for windings
14 Electromagnetic controlgear heating
15 High-voltage impulse testing
16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
22 No-load output voltage
Annex A (normative) - Test to establish whether a conductive
part is a live part which may cause an electric shock
Annex B (normative) - Particular requirements for thermally
protected lamp electromagnetic controlgear
Annex C (normative) - Particular requirements for electronic
lamp controlgear with means of protection against
overheating
Annex D (normative) - Requirements for carrying out the heating
tests of thermally protected lamp electromagnetic
controlgear
Annex E (normative) - Use of constant S other than
4 500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of
the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Method for selection of varistors
Annex J (informative) - Explanation of electromagnetic
controlgear temperatures
Annex K (normative) - Additional requirements for built-in
electromagnetic controlgear with double or
reinforced insulation
Bibliography
Defines particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps.
Committee |
CPL/34/3
|
DevelopmentNote |
Together with BS EN 61347-1 it supersedes BS EN 60922 To be read in conjunction with BS EN 61347-1 Supersedes 98/263277 DC (10/2003) Supersedes 04/300379 DC (10/2006) Supersedes 10/30230355 DC. (01/2013)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 61347-2-9:2012 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This second edition cancels and replaces the first edition published in 2000, Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a new Clause 14;
b) the word \'ballast\' is changed to \'electromagnetic controlgear\'.
This publication is to be read in conjunction with IEC 61347-1:2007.
Standards | Relationship |
EN 61347-2-9:2013 | Identical |
UNE-EN 61347-2-9:2013 | Identical |
NF EN 61347-2-9 : 2013 | Identical |
DIN EN 61347-2-9 : 2013 | Identical |
IEC 61347-2-9:2012 | Identical |
I.S. EN 61347-2-9:2013 | Identical |
SN EN 61347-2-9 : 2006 | Identical |
EN 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
EN 60192:2001 | Low pressure sodium vapour lamps - Performance specifications |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
IEC 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
EN 61347-2-1:2001/A2:2014 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) (IEC 61347-2-1:2000/A2:2013) |
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV | Lamp controlgear - Part 2-1: Particular requirements for startingdevices (other than glow starters) |
IEC 61167:2015 | Metal halide lamps - Performance specification |
IEC 62035:2014+AMD1:2016 CSV | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
EN 62035:2014 | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
EN 60662:2012 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60923:2005+AMD1:2006 CSV | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements |
IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
Access your standards online with a subscription