Foreword
1 Scope
2 Normative references
3 Definitions
4 Requirements
4.1 General
4.2 Functional requirements
4.3 Electrical requirements
4.4 Mechanical requirements
4.5 Markings
5 Tests
5.1 General
5.2 Functional tests
5.3 Electrical tests
5.4 Mechanical tests
6 Sampling procedure
7 Quality assurance plan
Annex A (normative) Chronology of tests
Annex B (normative) Instructions for use
Annex C (normative) Sampling procedure
Annex D (normative) Mechanical shock test
Annex E (normative) Symbol for marking
Annex F (informative) Acceptance tests
Annex G (informative) In-service care
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Figures
Tables
Applicable to portable detectors, with or without built-in power sources, to be used on electrical systems operating between 15 Hz to 60 Hz.
Committee |
PEL/78
|
DevelopmentNote |
Supersedes 01/201421 DC and 95/211875 DC (11/2002)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 61243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz.
This part applies only to resistive voltage detectors used in contact with the part to be tested, as a single unit or as a separate device completed by an adaptable insulating pole covered in IEC 60855 or IEC 61235. Other types of voltage detectors are not covered by this part of standard. Capacitive voltage detectors are covered in IEC 61243-1.
The upper voltage limit is in accordance with the tests described in this part of IEC 61243.
Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see Annex B).
NOTE 1 Except when otherwise specified, all the voltages defined in this standard refer to phase-to-phase voltages of three-phase systems. Resistive detectors may be used in other than three-phase systems, but the applicable phase-to-phase or phase-to-earth (ground) voltage shall be used to determine the operating voltage.
NOTE 2 Although this standard does not cover d.c. voltage detectors, some detectors may respond to d.c. voltage.
Standards | Relationship |
EN 61243-2:1997 | Identical |
UNE-EN 61243-2:1998 | Identical |
DIN EN 61243-2 : 2001 AMD 2 2003 | Identical |
IEC 61243-2:1995+AMD1:1999+AMD2:2002 CSV | Identical |
EN 61243-2:1997/A2:2002 | Identical |
NBN EN 61243-2 : 1998 AMD 2 2003 | Identical |
SN EN 61243-2 : 1997 AMD 1 2000 | Identical |
I.S. EN 61243-2:1999 | Identical |
NF EN 61243-2 : 2001 AMD 2 2003 | Identical |
EN 29002 : 1994 | QUALITY SYSTEMS - MODEL FOR QUALITY ASSURANCE IN PRODUCTION & INSTALLATION |
IEC 60855:1985 | Insulating foam-filled tubes and solid rods for live working |
IEC 61235:1993 | Live working - Insulating hollow tubes for electrical purposes |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60417-1:2002 | GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - PART 1: OVERVIEW AND APPLICATION |
EN 29004 : 1987 | QUALITY MANAGEMENT & QUALITY SYSTEM ELEMENTS - GUIDELINES |
HD 323.2.14 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE |
ISO 8402:1994 | Quality management and quality assurance — Vocabulary |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN 60417-2:1999 | Graphical symbols for use on equipment - Part 2: Symbol originals |
ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
ISO 9004:2009 | Managing for the sustained success of an organization A quality management approach |
HD 323.2.6 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST FC AND GUIDANCE: VIBRATION (SINUSOIDAL) |
IEC 61318:2007 | Live working - Conformity assessment applicable to tools, devices and equipment |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
EN 61235:1995 | Live working - Insulating hollow tubes for electrical purposes |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
EN 60651:1994/A2:2001 | SOUND LEVEL METERS (IEC 60651:1979/A2:2000) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
ISO 3745:2012 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms |
EN 60068-2-32:1993 | Basic environmental testing procedures - Part 2: Tests - Test Ed: Free fall |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60855:1996 | Insulating foam-filled tubes and solid rods for live working |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.