INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 General aspects of CONSTANCY TESTS
4.1 Preconditions
4.2 General conditions affecting test procedures
4.3 Establishment of BASELINE VALUES
4.4 Identification of equipment, instrumentation and test
conditions
4.5 Scope of the CONSTANCY TESTS
4.6 Test equipment, including PHANTOMS and TEST DEVICES
4.7 Frequency of CONSTANCY TESTS
5 Test methods for CT SCANNERS
5.1 Positioning of the PATIENT SUPPORT
5.2 PATIENT positioning accuracy
5.3 TOMOGRAPHIC SECTION THICKNESS
5.4 Dose
5.5 NOISE, UNIFORMITY AND MEAN CT NUMBERS
5.6 SPATIAL RESOLUTION
Annex A (informative) - Guidance on action to be taken
Annex B (informative) - Alternate test methods for SPATIAL RESOLUTION
Annex C (informative) - TOMOGRAPHIC SECTION THICKNESS for helical
scanning
Annex D (informative) - Visual method for LOW CONTRAST RESOLUTION
Bibliography
Index of terms
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Gives assistance in performing CONSTANCY TESTS on a CT SCANNER. It applies to those components of CT SCANNERS which influence the image quality, PATIENT dose and positioning.
Committee |
CH/62/2
|
DevelopmentNote |
Supersedes 93/504902 DC (11/2005) Supersedes 04/30124942 DC & BS 7725-2.6(1995). (11/2007)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 61223 provides assistance in performing constancy tests on a CT scanner. It applies to those components of CT scanners which influence the image quality, patient dose and positioning. This standard - defines the essential parameters which describe the performance of CT scanners with regard to image quality, patient dose and positioning; the list of parameters to be tested can be found in section 4.5; - defines the methods of testing the essential parameters; - provides criteria to be applied in the evaluation of data for compliance with the tolerances of the parameters specified by the accompanying documents and with respect to baseline values. These methods rely on non-invasive measurements, using appropriate test equipment, performed to ensure that the functional performance of equipment meets established criteria or to enable the early recognition of changes in the properties of components of the equipment. The aim is to verify compliance with specifications affecting the image quality, patient dose and patient positioning.
Standards | Relationship |
EN 50289-4-11:2002 | Identical |
IEC 61223-2-6:2006 | Identical |
EN 61223-2-6:2007 | Identical |
DIN EN 61223-2-6:2008-12 | Identical |
UNE-EN 61223-2-6:2008 | Identical |
I.S. EN 61223-2-6:2007 | Identical |
NF EN 61223-2-6 : 2007 | Identical |
SN EN 61223-2-6 : 1994 | Identical |
ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60522:1999 | Determination of the permanent filtration of X-ray tube assemblies |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
CFR 21(PTS800-1299) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299 |
ISO 5725-3:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method |
ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values |
ISO 5725-4:1994 | Accuracy (trueness and precision) of measurement methods and results Part 4: Basic methods for the determination of the trueness of a standard measurement method |
ISO 2092:1981 | Light metals and their alloys Code of designation based on chemical symbols |
IEC 60601-2-28:2017 | Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
IEC 61223-3-5:2004 | Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment |
IEC TR 60878:2015 | Graphical symbols for electrical equipment in medical practice |
IEC 60601-2-32:1994 | Medical electrical equipment - Part 2: Particular requirements for the safety of associated equipment of X-ray equipment |
ASTM E 1695 : 1995 | Standard Test Method for Measurement of Computed Tomography (CT) System Performance |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
EN 61223-3-5:2004 | Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment |
IEC 61223-2-4:1994 | Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
EN 60601-2-44:2009/A2:2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-44: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY (IEC 60601-2-44:2009/A2:2016) |
IEC 61223-2-5:1994 | Evaluation and routine testing in medical imaging departments - Part 2-5: Constancy tests - Image display devices |
IEC 60601-2-44:2009+AMD1:2012+AMD2:2016 CSV | Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography |