1 Scope and object
2 Normative references
3 Procedure and classification
4 Initial product compliance and tests
5 Periodic quality conformance assessment
5.1 Batch tests
5.2 Periodic tests
6 Initial product compliance and tests
6.1 Type A: Modules for printed circuits
6.2 Type B: Power supplies up to 250 W excluding
modules for printed circuits
6.3 Type C: Power supplies greater than 250 W
and up to 1 KW
6.4 Type D: Power supplies greater than 1 KW
7 Periodic quality conformance assessment -
Batch test
8 Periodic quality conformance assessment -
Periodic tests
8.1 Type A: Modules for printed circuits
8.2 Type B: Power supplies up to 250 W excluding
modules for printed circuits
8.3 Type C: Power supplies greater than 250 W
and up to 1 KW
8.4 Type D: Power supplies greater than 1 KW
Annex ZA (normative) Normative references to
international publications
with their corresponding
European publications
Applicable to power supplies for general purpose applications. Objective is to set down the requirements for the performance of low-voltage power supply devices of assessed functionality intended for serial production.
Committee |
PEL/22
|
DevelopmentNote |
Also numbered as IEC 61204-6 (06/2001) Supersedes 95/200932 DC. (01/2006)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This part of IEC 61204 applies to power supplies for general purpose applications. These power supplies carry out an a.c. to d.c. conversion or a d.c. to d.c. conversion. Appropriate provisions for safety will be found in the relevant product standards.
As far as input characteristics are concerned, this standard applies to all d.c. or a.c. source voltages with a rated value of up to 600 V.
As far as output characteristics are concerned, this standard applies only to the supplies of d.c. voltages of less than 200 V with a power limited to 2,5 kW; the latter power can be extended to 30 kW by taking care of the appropriate test methods.
The object of this part of IEC 61204 is to set down the requirements for the performance of low-voltage power supply devices of assessed functionality intended for serial production. If other performance requirements or quality assurance have been agreed by a contract, the latter prevails.
This part of IEC 61204 is intended as a guidance for the improvement of the performance of large series.
For performance and quality conformance inspection, the numbering of the clauses and subclauses of this part of IEC 61204 refer, unless stated otherwise, to IEC 61204.
Standards | Relationship |
NBN EN 61204-6 : 2001 | Identical |
UNE-EN 61204-6:2001 | Identical |
DIN EN 61204-6 : 2001 | Identical |
NF EN 61204-6 : 2001 | Identical |
I.S. EN 61204-6:2001 | Identical |
SN EN 61204-6 : 2001 | Identical |
EN 61204-6:2001 | Identical |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 61204:1995/A1:2001 | LOW-VOLTAGE POWER SUPPLY DEVICES, D.C. OUTPUT - PERFORMANCE CHARACTERISTICS (IEC 61204:1993, MODIFIED + A1:2001) |
IEC 61204:1993+AMD1:2001 CSV | Low-voltage power supply devices, d.c. output - Performance characteristics |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.