BS EN 61071:2007
Current
The latest, up-to-date edition.
Capacitors for power electronics
Hardcopy , PDF
English
02-29-2008
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
4.1 Normal service conditions
4.2 Unusual service conditions
5 Quality requirements and tests
5.1 Test requirements
5.2 Classification of tests
5.3 Capacitance and tan delta measurements (routine test)
5.4 Measurement of the tangent of the loss angle (tan delta)
of a capacitor (type test)
5.5 Voltage test between terminals
5.6 AC voltage test between terminals and case
5.7 Test of internal discharge device
5.8 Sealing test
5.9 Surge discharge test
5.10 Thermal stability test
5.11 Self-healing test
5.12 Resonance frequency measurement
5.13 Environmental testing
5.14 Mechanical testing
5.15 Endurance test
5.16 Destruction test
5.17 Disconnecting test on internal fuses
6 Overloads
6.1 Maximum permissible voltages
7 Safety requirements
7.1 Discharge device
7.2 Case connections
7.3 Protection of the environment
7.4 Other safety requirements
8 Markings
8.1 Marking of the units
9 Guide to installation and operation
9.1 General
9.2 Choice of rated voltage
9.3 Operating temperature
9.4 Special service conditions
9.5 Overvoltages
9.6 Overcurrents
9.7 Switching and protective devices
9.8 Choice of creepage distance and clearance
9.9 Connections
9.10 Parallel connections of capacitors
9.11 Series connections of capacitors
9.12 Magnetic losses and eddy currents
9.13 Guide for internal fuse and disconnector protection in
capacitors
9.14 Guide for unprotected capacitors
Annex A (informative) - Waveforms
Annex B (normative) - Operational limits of capacitors with
sinusoidal voltages as a function of frequency and
at maximum temperature (theta[max])
Annex C (normative) - Resonance frequency measuring methods -
Examples
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Bibliography
Defines an extremely wide range of capacitor technologies for numerous applications, e.g. overvoltage protection, d.c. and a.c. filtering, switching circuits, d.c. energy storage, auxiliary inverters, etc. Applies to capacitors for power electronics applications.
Committee |
W/-
|
DevelopmentNote |
Supersedes BS EN 61071-1, BS EN 61071-2 and 05/30134428 DC. (02/2008)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard applies to capacitors for power electronics applications. The operating frequency of the systems in which these capacitors are used is usually up to 15kHz, while the pulse frequencies may be up to 5 to 10 times the operating frequency. The standard distinguishes between a.c. and d.c. capacitors which are considered as components when mounted in enclosures. This standard covers an extremely wide range of capacitor technologies for numerous applications, e.g. overvoltage protection, d.c. and a.c. filtering, switching circuits, d.c. energy storage, auxiliary inverters, etc.
Standards | Relationship |
IEC 61071:2007 | Identical |
I.S. EN 61071:2007 | Identical |
DIN EN 61071 : 2008 | Identical |
NF EN 61071 : 2007 | Identical |
UNE-EN 61071:2007 | Identical |
IEC 61071:2017 | Identical |
EN 61071:2007 | Identical |
NBN EN 61071 : 2007 | Identical |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
IEC 61287-1:2014 | Railway applications - Power converters installed on board rolling stock - Part 1: Characteristics and test methods |
IEC 60931-2:1995 | Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1000 V - Part 2: Ageing test and destruction test |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
IEC 61881:1999 | Railway applications - Rolling stock equipment - Capacitors for power electronics |
IEC 60252-2:2010+AMD1:2013 CSV | AC motor capacitors - Part 2: Motor start capacitors |
IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
IEC 61270-1:1996 | Capacitors for microwave ovens - Part 1: General |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC 60077-2:2017 | Railway applications - Electric equipment for rolling stock - Part 2: Electrotechnical components - General rules |
IEC 60831-2:2014 | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 2: Ageing test, self-healing test and destruction test |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC TS 60110-2:2000 | Power capacitors for induction heating installations - Part 2: Ageing test, destruction test and requirements for disconnecting internal fuses |
IEC 60831-1:2014 RLV | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation |
IEC 60252-1:2010+AMD1:2013 CSV | AC motor capacitors - Part 1: General - Performance, testing andrating - Safety requirements - Guidance for installation and operation |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60050-436:1990 | International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 60077-1:2017 | Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC TS 60871-2:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 2: Endurance testing |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60110-1:1998 | Power capacitors for induction heating installations - Part 1: General |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.