BS EN 60974-1:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Arc welding equipment Welding power sources
Hardcopy , PDF
04-24-2019
English
08-31-2012
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental conditions
5 Tests
6 Protection against electric shock
7 Thermal requirements
8 Thermal protection
9 Abnormal operation
10 Connection to the supply network
11 Output
12 Control circuits
13 Hazard reducing device
14 Mechanical provisions
15 Rating plate
16 Adjustment of the output
17 Instructions and markings
Annex A (informative) - Nominal voltages of supply
networks
Annex B (informative) - Example of a combined
dielectric test
Annex C (normative) - Unbalanced load in case of
a.c. tungsten inert-gas welding power
sources
Annex D (informative) - Extrapolation of temperature
to time of shutdown
Annex E (normative) - Construction of supply circuit
terminals
Annex F (informative) - Cross-reference to non-SI units
Annex G (informative) - Suitability of supply network
for the measurement of the true r.m.s.
value of the supply current
Annex H (informative) - Plotting of static characteristics
Annex I (normative) - Test methods for a 10 Nm impact
Annex J (normative) - Thickness of sheet metal for
enclosures
Annex K (informative) - Examples of rating plates
Annex L (informative) - Graphical symbols for arc welding
equipment
Annex M (informative) - Efficiency
Annex N (normative) - Touch current measurement in
fault condition
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines safety and performance requirements of welding power sources and plasma cutting systems.
Committee |
WEE/6
|
DevelopmentNote |
Supersedes BS 638-10(1990), 01/709577 DC and 95/711395 DC Together with BS EN 60974-7, it supersedes BS EN 50192. (10/2003) Supersedes 04/30095682 DC. (02/2006) Supersedes 08/30195564 DC. (08/2012)
|
DocumentType |
Standard
|
Pages |
116
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of IEC 60974 is applicable to power sources for arc welding and allied processes designed for industrial and professional use, and supplied by a voltage not exceeding 1 000 V, or driven by mechanical means.
This part of IEC 60974 specifies safety and performance requirements of welding power sources and plasma cutting systems.
This part of IEC 60974 is not applicable to welding power sources for manual metal arc welding with limited duty operation which are designed mainly for use by laymen and designed in accordance with IEC 60974-6.
This part of IEC 60974 is not applicable to testing of power sources during periodic maintenance or after repair.
NOTE 1 Typical allied processes are electric arc cutting and arc spraying.
NOTE 2 AC systems having a nominal voltage between 100 V and 1 000 V are given in Table 1 of IEC 60038:2009.
NOTE 3 This part of IEC 60974 does not include electromagnetic compatibility (EMC) requirements.
Standards | Relationship |
UNE-EN 60974-1:2013 | Identical |
IEC 60335-2-109:2010 | Identical |
IEC 60335-2-109:2010/AMD2:2016 | Identical |
IEC 60974-1:2012 | Identical |
DIN EN 60974-1 : 2013 | Identical |
NEN EN IEC 60974-1 : 2012 | Identical |
I.S. EN 60974-1:2012 | Identical |
NF EN 60974-1 : 2012 | Identical |
NBN EN 60974-1 : 2015 | Identical |
IEC 60974-1:2017 | Identical |
EN 60974-1:2012 | Identical |
SN EN 60974-1 : 2005 | Identical |
NEN EN 60974-1 : 1991 | Identical |
BS 4515-2:1999 | Specification for welding of steel pipelines on land and offshore Duplex stainless steel pipelines |
BS 7570:2000 | Code of practice for validation of arc welding equipment |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60038:2009 | IEC standard voltages |
EN 61558-2-4:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers |
EN 60974-7:2013 | Arc welding equipment - Part 7:Torches |
IEC 60245-6:1994 | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 6: Arc welding electrode cables |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 61558-2-4:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers |
ISO 13732-1:2006 | Ergonomics of the thermal environment — Methods for the assessment of human responses to contact with surfaces — Part 1: Hot surfaces |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
IEC 60974-10:2014+AMD1:2015 CSV | Arc welding equipment - Part 10: Electromagnetic compatibility (EMC)requirements |
CFR 16(PTS1000-END) : 0 | COMMERCIAL PRACTICES - FEDERAL TRADE COMMISSION - CONSUMER PRODUCT SAFETY COMMISSION |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60974-12:2011 | Arc welding equipment - Part 12: Coupling devices for welding cables |
IEC 60974-6:2015 | Arc welding equipment - Part 6: Limited duty equipment |
HD 22-1 : 200S4 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOSETTING INSULATION - GENERAL REQUIREMENTS |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC TR 60755:2008 | General requirements for residual current operated protective devices |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 62079:2001 | Preparation of instructions - Structuring, content and presentation |
HD 22.6 : S2 AMD 2 2004 | RUBBER INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - ARC WELDING CABLES |
ISO 3864-1:2011 | Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings |
IEC 60974-9:2010 | Arc welding equipment - Part 9: Installation and use |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
ISO 17846:2004 | Welding and allied processes — Health and safety — Wordless precautionary labels for equipment and consumables used in arc welding and cutting |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60974-7:2013 | Arc welding equipment - Part 7: Torches |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
IEC 60050-851:2008 | International Electrotechnical Vocabulary (IEV) - Part 851: Electric welding |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.